Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 27 for “"implantable biomedical devices"”
-
Electromagnetic Energy and Data Transfer for Low-Power Implantable Biomedical Devices
… with high data rate (e.g. 3.125 Mbps) implantable circuitry located few centimeters under the skin using spread spectrum technique. Different methods and frequency bands were analyzed to choose the appropriate 2.4-GHz ISM band. The nominal power consumption of the implantable baseband …
-
Wireless power transfer for implantable biomedical devices using adjustable magnetic resonance
… acquisition from rodents is important in biomedical research and requires a long-term powering method. A wireless power transfer (WPT) scheme is desirable to power the telemetric devices for rodents. This dissertation investigates a WPT system to deliver power from a stationary source …
-
Energy Harvesting from the Human Body for Portable Biosensors and Implantable Biomedical Devices
Wearable biosensors and implantable biomedical devices frequently rely on battery-stored energy, whose replacement might be associated with pain, surgeries and data acquisition discontinuity. Energy harvesting is one way of tackling those issues. The cardiovascular system represents a reliable …
-
THE SPICY, THE EVERLASTING AND THE UNEXPECTED: INVESTIGATING THREE COMPOUNDS THAT SUPPRESS MACROPHAGES AND MYOFIBROBLASTS TO REDUCE BIOMATERIAL-INDUCED FIBROSIS
… fibrosis. The lifetime and efficacy of implantable biomedical devices are determined by the foreign body response. Immediately after implantation, proteins nonspecifically adsorb onto the material and initiate inflammation. Macrophages recruited to the site can differentiate into M1 and …
-
Analyzing the Cytocompatibility of Polymeric Biomaterials Synthesized Using Ring-Opening Copolymerization
… pillar and cornerstone in the manufacturing of devices for medical uses. Traditional synthesis and manufacturing of these materials have utilized metal-catalyzed reactions which run the risk of leaving trace amounts of metal ions in the final synthesis products. Because of the known detriments …
-
Innovative transceiver approaches for low-power near-field and far-field applications
… tactical and geological imaging, and implantable biomedical devices (IMDs), leading to the proposal and implementation of low-power wireless solutions for these applications in SiGe BiCMOS and CMOS and platforms.
-
Mechanical properties of soft interfaces.
As the trend of miniaturization in devices and systems continues, it is important to understand their mechanical properties at the nanometer scale. In Micro-Electro-Mechanical Systems (MEMs) and implantable biomedical devices, interfacial forces (friction and adhesions) responsible for device …
-
Using Red Blood Cells in Microbial Fuel Cell Catholyte Solution to Improve Electricity Generation
… a wayto generate electricity in vivo to power implantable biomedical devices (e.g., pacemaker) using the body's own natural materials. Blood-based MFCs, using red blood cells (RBCs) as catholyte with recycling between the cathodic and aeration chambers, were continuously fed using glucose at 37 …
-
Titania nanotube arrays: interfaces for implantable devices
… (20-25 million people) that have implanted biomedical devices, biomaterial failure and the need for revision surgery are critical concerns. The major causes for failure in implantable biomedical devices promoting a need for re- implantation and revision surgery include thrombosis, …
-
Ultra-low-power SRAM design in high variability advanced CMOS
… Highly energy-constrained systems (e.g. implantable biomedical devices, multimedia handsets, etc.) are an important class of applications driving ultra-low-power SRAMs. This thesis analyzes the energy of an SRAM sub-array. Since supply- and threshold-voltage have a strong effect, targets …
-
Design of a variable rate low power SAR ADC with bypass window for biomedical application
… an increasing demand for portable, wearable or implantable biomedical devices. These devices generally require extremely long battery life-time which in turn demands extremely low-power band-pass filters, low-noise amplifiers and low-power ADC. SAR ADC is typically adopted in these devices …
-
Miniaturization of the Network Analyzer as an Interface Circuit for Wearable Resonance-Based Sensors
… future of the Internet of Things, wearable and implantable biomedical devices, sensors for harsh environments, etc. For developing wireless telemetry sensors, Vector Network Analyzer (VNA) is a powerful measurement instrument that can measure scattering parameters (S-Parameters) of single and …
-
Wireless Power Transfer For Biomedical Applications
… The focus is on delivering power to implantable biomedical devices. The objective of this research is to optimize the size and performance of the implanted wireless biomedical sensors by: (1) proposing a hybrid multiband communication system for implantable devices that combines …
-
Design of Analog CMOS Circuits for Batteryless Implantable Telemetry Systems
A wireless biomedical telemetry system is a device that collects biomedical signal measurements and transmits data through wireless RF communication. Testing medical treatments often involves experimentation on small laboratory animals, such as genetically modified mice and rats. Using batteries as …
-
Application of Smart Materials in Energy Harvesting and Wave Propagation
… First, the energy harvesting at small scale for biomedical applications is studied. Two different novel configurations, one linear and one nonlinear, are proposed to achieve the goals for an energy harvester in implantable biomedical devices such as pacemakers. The goals include but not limited …
-
A Novel Batteryless Pacemaker: Design, Development, and In Vivo Study in an Ovine Model
… specifications were then used to design an implantable rectenna, which was simulated and optimized using Advanced Design System (ADS) and ANYS-High Frequency Structure Simulator (HFSS). The performance of the antenna was initially tested in vitro and was then integrated with a separately …
-
Leak rate prediction methods for hermetically sealed devices
… sensitive components such as those found in implantable biomedical devices and MEMS devices. Knowledge of the leak rate of the packaging is also required so that the service lifetime of these devices can be predicted. Determining the leak rate of a hermetically sealed device is typically …
-
Flexible Supercapacitors Utilising the Multifunctional Rôle of Ionic Liquids
… on flexible, ultrathin and safe energy storage devices such as supercapacitors or batteries is an emerging area to “power-up” the next-generation of portable and flexible electronics such as mobile phones, computers, displays, wearable and implantable biomedical devices. In general, a …
-
Liquid Crystal Elastomers for Small-Scale Biomedical Devices and Electronics
… as soft actuators and robots, dynamic medical devices, and artificial muscles. While the large, programmable shape-changing behavior of LCEs is extensively reported, there are some critical limitations that currently impede the use of these “smart materials” for the development of micro-scale …
Page 1 of 2