Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 83 for “"implantable device"”.

  1. Enhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator

    … increases, so too does the need and use of implantable mechanical circulatory support devices, such as ventricular assist devices (VADs) and total artificial hearts (TAHs), for patient treatment. These devices assist the failing heart by taking over the blood pumping process either partially …

    texas Repository record for Enhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator (opens in a new tab)

  2. Implantable device for Aβ immunoselective nanopheresis in the cerebrospinal fluid to treat Alzheimer’s Disease

    El objetivo general de esta Tesis se ha centrado en proporcionar: a) una prueba del principio del mecanismo de acción de la aféresis selectiva y b) una prueba de concepto de la pseudoliberación IT para mostrar los efectos de esta nueva estrategia terapéutica. Para ello, los objetivos específicos …

    oviedo Repository record for Implantable device for Aβ immunoselective nanopheresis in the cerebrospinal fluid to treat Alzheimer’s Disease (opens in a new tab)

  3. Development of a tissue engineered implantable device for the surgical repair of the peripheral nervous system

    … recovery. Tissue-engineered cellular bridging devices for surgical implantation into peripheral nerve injury sites could provide an attractive alternative to the autograft. This project reports the development of a robust, anisotropic biomaterial with highly aligned cells that can form the …

    the-open-u Download PDF for Development of a tissue engineered implantable device for the surgical repair of the peripheral nervous system (opens in a new tab)

  4. A multiregion-integral-equation method for wearable and implantable device design and evaluation : modeling, high-performance algorithms, and postprocessing

    … role during the design phase of wireless devices that operate near, on, or inside the human body. Simulating the electromagnetic interaction of devices with a nearby human body, however, presents significant challenges that manifest in three areas of the simulation process: (i) Modeling …

    texas Repository record for A multiregion-integral-equation method for wearable and implantable device design and evaluation : modeling, high-performance algorithms, and postprocessing (opens in a new tab)

  5. Towards the development of a multi-drug eutectic containing implantable device for enhanced post-operative recovery after peritoneal surgery

    … studies aimed at facilitating the design of a device intended for implantation within the peritoneal cavity to enhance the control of pain and inflammation. When combined lidocaine (LID) and ibuprofen (IBU) formed a stable eutectic system. These were characterized across various component molar …

    qu-belfast Repository record for Towards the development of a multi-drug eutectic containing implantable device for enhanced post-operative recovery after peritoneal surgery (opens in a new tab) Download PDF for Towards the development of a multi-drug eutectic containing implantable device for enhanced post-operative recovery after peritoneal surgery (opens in a new tab)

  6. Adaptive power management for cyber-physical system

    … Then a novel cyber-physical system, known as implantable device, is investigated. Adaptive power management framework is developed to optimize the application performance while maintaining a safe operating temperature and respecting system constraints. The developed framework can also be …

    gatech Repository record for Adaptive power management for cyber-physical system (opens in a new tab)

  7. Closed-loop bladder function control for rats using optogenetics

    Implantable devices are continuously proving to be an effective and reliable method of treatment for human patients in clinical settings. One example class of these devices is closed-loop or conditional-triggering implantable devices, which monitor physiological signals and provide necessary …

    uiuc Repository record for Closed-loop bladder function control for rats using optogenetics (opens in a new tab)

  8. Novel Design of Low Power Device for Measurement and Conversion of Continuous Cellular Pulse-Rate Signal to Optical for Potential Use in Implantable Devices

    Implantable devices have become increasingly commonplace as the technologies of electronic component manufacturing have allowed engineers to develop increasingly more capable devices at small scale. These devices are designed to survive the unique environment of the body. These design requirements …

    unr Repository record for Novel Design of Low Power Device for Measurement and Conversion of Continuous Cellular Pulse-Rate Signal to Optical for Potential Use in Implantable Devices (opens in a new tab)

  9. Clinical Compatibility of an Implantable Pressure Sensing Device With Consideration of the Intracranial Pressure Application

    Implantable pressure sensing devices have the potential to improve patient management and treatment outcomes in a wide variety of conditions, including monitoring intracranial pressure (ICP) in hydrocephalus patients. The intracranial pressure application requires a long-term implantable device …

    auckland-ms Repository record for Clinical Compatibility of an Implantable Pressure Sensing Device With Consideration of the Intracranial Pressure Application (opens in a new tab)

  10. Functional Locomotor Recovery After Spinal Cord Injury Using AI-Based Closed-Loop Stimulation

    … on the development and validation of a fully implantable device designed for motion-dependent closed-loop plantar cutaneous augmentation. The system's functionality and performance are thoroughly assessed, ensuring its suitability for the intended purpose. Next, the dissertation explores the …

    tamu Repository record for Functional Locomotor Recovery After Spinal Cord Injury Using AI-Based Closed-Loop Stimulation (opens in a new tab)

  11. A Low Power Integrated Circuit for Implantable Biosensor Incorporating an On-Chip FSK Modulator

    … blood glucose level at home or at office with an implantable sensor which can also trigger insulin pump attached to the body. The insulin delivery system can be precisely controlled by the electronics embedded in the implantable device.</p> <p>In this thesis, a low power integrated circuit for the …

    ut-knoxville Repository record for A Low Power Integrated Circuit for Implantable Biosensor Incorporating an On-Chip FSK Modulator (opens in a new tab)

  12. Patients’ Satisfaction with Existing Dry Mouth Therapies and Willingness to Pay for an Artificial Salivary Gland

    … and willingness-to-pay for an artificial implantable salivary gland. Methods: A survey was conducted to obtain patients’ satisfaction with current xerostomia management strategies, effect of Xerostomia on their oral and general health, willingness to adopt an artificial salivary gland …

    uconn-diss Repository record for Patients’ Satisfaction with Existing Dry Mouth Therapies and Willingness to Pay for an Artificial Salivary Gland (opens in a new tab)

  13. Wireless power transmission and communication system for implantable devices in rodents

    … industry. This has led to the miniaturization of implantable devices for rodents to reduce the physical stress on the animals. The most common power source for implantable devices are batteries, which are heavy, take up space, and need to be replaced. In this thesis, an inductive power and …

    texas Repository record for Wireless power transmission and communication system for implantable devices in rodents (opens in a new tab)

  14. Thin film nanoporous silica and graphene based biofuel cells (iBFCs) for low-power implantable medical device applications

    … silica based biofuel cell is for a blood vessel implantable device. Blood vessel implantable Biofuel Cells (iBFCs) are subjected to higher glucose concentrations and blood flow rates. However, reduction in the implant thickness is critical for the intra-vascular implantable Biofuel cells. …

    texas Repository record for Thin film nanoporous silica and graphene based biofuel cells (iBFCs) for low-power implantable medical device applications (opens in a new tab)

  15. SILK FIBROIN ELECTRONICS: MATERIAL TECHNOLOGY FOR SOFT AND CONFORMAL ELECTRICAL SENSOR IMPLANTS

    … to enable a wide range of soft and conformal implantable electrical sensors on sustainable silk substrates, the first of its kind, that provide a conformal lamination on the curvilinear tissue geometries. First, we report the material technology for realizing silk electrode sensors to the …

    nus Repository record for SILK FIBROIN ELECTRONICS: MATERIAL TECHNOLOGY FOR SOFT AND CONFORMAL ELECTRICAL SENSOR IMPLANTS (opens in a new tab) Download file for SILK FIBROIN ELECTRONICS: MATERIAL TECHNOLOGY FOR SOFT AND CONFORMAL ELECTRICAL SENSOR IMPLANTS (opens in a new tab)

  16. Implantable intracardiac bioimpedance system

    An implantable intracardiac bioimpedance system has been designed to measure the real and imaginary parts of impedance in a dynamic cardiac setting. The system is broken into two parts: an implantable wireless device and a desktop base station. This measurement is performed using both tetrapolar …

    texas Repository record for Implantable intracardiac bioimpedance system (opens in a new tab)

  17. Verification Process of the St. Jude Medical Atrial Fibrillation Implantable Cardiac Monitor Device

    The St. Jude Medical SJM ConfirmTM Implantable Cardiac Monitor (ICM) is a small implantable device that is used to detect arrhythmias and stores the electrogram (EGMs) records for physicians to verify the arrhythmia. The objective of this device is to provide physicians with the technology to …

    calpoly Repository record for Verification Process of the St. Jude Medical Atrial Fibrillation Implantable Cardiac Monitor Device (opens in a new tab)

  18. Design of An Externally Programmable, Implantable, Integrated Cerebellar Stimulator

    … an increasing number of cases. Presently, most implantable neurological stimulation systems are passive and powered externally, whereby the stimulation is delivered extra-corporeally via an externally located electro-magnetic induction coil. Unfortunately, systems such as these often tend to be …

    marquette Repository record for Design of An Externally Programmable, Implantable, Integrated Cerebellar Stimulator (opens in a new tab)

  19. ST Monitoring on the Programmer for Implantable Cardioverter Devices

    … of the disease. In order to support the new implantable devices with ST Monitoring capability, the programmer software was updated to support this new feature in the device. This thesis discusses the work on the programmer. Chapter 1 begins with a background of how monitoring technology in an …

    calpoly Repository record for ST Monitoring on the Programmer for Implantable Cardioverter Devices (opens in a new tab)

  20. Reduced-complexity epileptic seizure prediction with EEG.

    … of the research is to develop and prototype an implantable device that can reliably provide alarms prior to a seizure in real-time. The specific objective is to develop a patient-specific algorithm that can predict seizures in ECoG/iEEG with high sensitivity and low false positive rate as well …

    umn Repository record for Reduced-complexity epileptic seizure prediction with EEG. (opens in a new tab)

Page 1 of 5