Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"induced draft"”

  1. Fluid flow and thermal analysis in induced draft cooling towers

    Cooling towers are heat rejection devices that utilize ambient air to cool hot water. The ambient air is drawn into the tower and brought into direct contact with hot water and where the heat and vapour get transferred. Fluid flow distribution in the tower can result in better thermal performance. …

    alberta Repository record for Fluid flow and thermal analysis in induced draft cooling towers (opens in a new tab)

  2. Design optimization of mechanical induced-draft counter-flow wet cooling towers

    … and hydrodynamic performance of mechanical induced-draft counter-flow wet cooling towers through the solution of a one-dimensional zone-specific thermodynamic model and air draft equation. Furthermore, the analysis component of the framework evaluates the environmental impact of cooling …

    alberta Repository record for Design optimization of mechanical induced-draft counter-flow wet cooling towers (opens in a new tab)

  3. Dynamic Base Analysis for the NSGS Induced Draft Fans by Single Degree-of-freedom Models

    … dynamic response for two identical 92" diameter induced draft fans at the Northside Generating Station, in Jacksonville, Florida included soil testing and physical monitoring to determine actual soil characteristics and fan motions. The history of dynamic imbalance of these machines is long and …

    ucf Repository record for Dynamic Base Analysis for the NSGS Induced Draft Fans by Single Degree-of-freedom Models (opens in a new tab)

  4. Use of evaporative coolers for close circuiting of the electroplating process

    … This master’s study proposes the use of an induced draft evaporative cooling tower for facilitation of evaporation in the plating bath. For total recovery of the rinse tank water, the rate of evaporation from the plating bath has to be equivalent to the rinse tanks make up water …

    dut Repository record for Use of evaporative coolers for close circuiting of the electroplating process (opens in a new tab)

  5. On natural convection in a large civil gas turbine

    … gas path.</p> <p>The interaction between the induced draft in the main gas path (due to natural convection) and obstructions in this area has been proven to be critical in defining the severity of thermal rotor bow - the thermal gradient that develops across the rotor drum during shutdown. Two …

    oxford Repository record for On natural convection in a large civil gas turbine (opens in a new tab)

  6. Analysing the impact of refurbishing precooling towers on a deep-level mine

    … solutions to common problems associated with induced draft precooling towers. The recommendation will form the refurbishment solution to be implemented in Step 3. In Step 4, the precooling tower performance is re-assessed. If the performance is satisfactory, the impact is evaluated in Step 5 …

    nwu-za Repository record for Analysing the impact of refurbishing precooling towers on a deep-level mine (opens in a new tab)

  7. Design of Air-cooled Microchannel Condensers for Mal-distributed Air Flow Conditions

    … auxiliary parts in an outdoor unit, with an induced draft fan at the top of this enclosure. Such a configuration results in significant mal-distribution of the air flow arriving at the condenser, and leads to a decrease in performance. This work addresses the issue of mal-distribution by …

    gatech Repository record for Design of Air-cooled Microchannel Condensers for Mal-distributed Air Flow Conditions (opens in a new tab)

  8. A modelling methodology to quantify the impact of plant anomalies on ID fan capacity in coal fired power plants

    … to losses incorrectly being ascribed to the Induced Draught (ID) fan, where detection occurs, while the problem actually originates elsewhere in the plant. The focus of this study was to develop and demonstrate a modelling methodology to quantify the effects of major plant anomalies on the …

    cape-town Repository record for A modelling methodology to quantify the impact of plant anomalies on ID fan capacity in coal fired power plants (opens in a new tab)

  9. Radon reduction, improvement of indoor air quality, and energy savings through an original solar ventilation system

    … and reduced radon infiltration with induced-draft ventilation. Solar heating of intake air enables the SRRS to operate with energy gain during cold weather, and the blower provides low-energy summertime cooling when outdoor temperatures drop below indoor levels. The system was …

    northern-iowa Repository record for Radon reduction, improvement of indoor air quality, and energy savings through an original solar ventilation system (opens in a new tab)

  10. Evaluation of fabric filter plant operating costs as a function of bag filter dimensions

    … and this has significant implications on the induced draft (ID) fan power requirements. Power stations in South Africa typically have three different bag diameters in its fleet of FFP units, with all having roughly the same length. However, in-house expertise on selecting the optimum bag size, …

    nwu-za Repository record for Evaluation of fabric filter plant operating costs as a function of bag filter dimensions (opens in a new tab)