Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"inertia response"”.

  1. Optimal Planning of Virtual Inertia Installations to Improve the Power System Frequency Response

    … deployed, the system relies on the natural inertia response of the synchronous generators to maintain the active power balance at the sacrifice of changes in the generators' rotational speeds. As the power frequency is decided collectively by the rotational speeds of all synchronous …

    sask Repository record for Optimal Planning of Virtual Inertia Installations to Improve the Power System Frequency Response (opens in a new tab)

  2. Development of Large-Scale Models and HVDC Control Strategies to Improve Resiliency of North American Power System

    … characteristics of the power system like inertia, response time and control behavior. However, these assumptions are not accurate and a need to reevaluate the system has become a priority. With improved wide area measurements and analysis techniques detecting wide area phenomena, analyzing …

    utk-theses Repository record for Development of Large-Scale Models and HVDC Control Strategies to Improve Resiliency of North American Power System (opens in a new tab)

  3. Compensating for the effects of reduced synchronous inertia on frequency stability using virtual synchronous generators

    … have provided frequency stability through their inertia and governor responses. As more renewable energy sources (RES), particularly wind and solar, are added to the grid, they displace synchronous generators. Many of these RES generators do not inherently contribute inertia to the system, so …

    uiuc Repository record for Compensating for the effects of reduced synchronous inertia on frequency stability using virtual synchronous generators (opens in a new tab)

  4. Frequency Stability in Low-Inertia Power Systems

    … led to a decline in the available rotational inertia from these synchronous generators that provides immediate frequency response in the event of a disturbance to the grid. The result is a larger increase in the frequency deviation, rate of change of frequency, and a slower settling time, all …

    washington Repository record for Frequency Stability in Low-Inertia Power Systems (opens in a new tab)

  5. Enhancing Frequency Stability of Low-Inertia Grids with Novel Security Constrained Unit Commitment Approaches

    … generators are gradually being replaced by low-inertia inverter-based resources. Such transition introduces more complicated operation conditions. Insufficient system inertia is one of the challenges which would lead to dramatical change in rate of change of frequency (RoCoF) and further results …

    houston Repository record for Enhancing Frequency Stability of Low-Inertia Grids with Novel Security Constrained Unit Commitment Approaches (opens in a new tab)

  6. Providing Virtual Inertia Through Power Electronics

    … with general vector control cannot provide inertia for the grid due to lack of kinetic energy. This tends to degrade the safety and stability of the grid with the increasing penetration of renewable energy sources. To cope with this issue, virtual synchronous generator (VSG) has been …

    unsw Repository record for Providing Virtual Inertia Through Power Electronics (opens in a new tab)

  7. Σεισμική καταπόνηση Χ.Υ.Τ.Α.: μηχανισμοί αστοχίας και μέθοδοι ενίσχυσης

    … of reinforced soil. Additionally, the dynamic response of MSW landfills is examined, taking also into account the mechanical properties of waste material and the excitation’s characteristics. The seismic stability is evaluated for two main failure wedges: (a) circular failure surface developed …

    greece Repository record for Σεισμική καταπόνηση Χ.Υ.Τ.Α.: μηχανισμοί αστοχίας και μέθοδοι ενίσχυσης (opens in a new tab)

  8. Improving Grid Frequency Response using Wind Generation Resources

    … Electric Reliability Corporation (NERC) in response to the increasing mix of Wind Generation Resources and growing concerns of system stability and reliability in US interconnections (especially ERCOT region). This concern is due to lack of inertia, primary and secondary frequency response …

    ttu Repository record for Improving Grid Frequency Response using Wind Generation Resources (opens in a new tab)

  9. Modular multi-level converter based multi-terminal HVDC system for offshore wind power transmission

    … loss analysis, and how MTDC system would provide inertia support for weak AC grids. Contributions of this thesis include improving system transient stability under unbalanced grid condition by using symmetrical components control methods, and introducing a novel way of determining and calculating …

    unsw Repository record for Modular multi-level converter based multi-terminal HVDC system for offshore wind power transmission (opens in a new tab)

  10. Analysis of converter small signal model limitations and oscillation propagation in medium voltage and high voltage DC systems

    … been discussion in the literature comparing the inertial response provided by grid forming and following controllers, showing grid following converters can provide similar inertial responses to grid forming under certain conditions. However, the effect of providing an inertia response on …

    strathclyde Repository record for Analysis of converter small signal model limitations and oscillation propagation in medium voltage and high voltage DC systems (opens in a new tab)