  1. Effect of Oxygen on CO2 Corrosion of Mild Steel

    … impedance spectroscopy (EIS), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and infinite focus microscopy (IFM)techniques. It has been shown that galvanic corrosion will occur between mild steel exposed to pure CO2 and mild steel exposed to a mixture of CO2 and O2. It …

    ohiolink Repository record for Effect of Oxygen on CO2 Corrosion of Mild Steel (opens in a new tab)

  2. Characterization and Quantification of Early Stages for Organic Coatings Applied on AA2024/AA7075 by Correlating Frequency Domain Approach in Real Time

    … and surface analysis, such as Atomic Force Microscopy (AFM) and Infinite Focus Microscopy (IFM) will be used to validate the experimental and theoretical results developed describing the transport mechanisms occurring within the coating during early stages.

    ohiolink Repository record for Characterization and Quantification of Early Stages for Organic Coatings Applied on AA2024/AA7075 by Correlating Frequency Domain Approach in Real Time (opens in a new tab)

  3. Multi-Informative and Specific Detection of Blood in Fingermarks via MALDI-MS Based Strategies

    … with blood is difficult and subjective. Infinite focus microscopy was investigated for its potential to facilitate quantitative differentiation between the different deposition scenarios. However, results were highly dependent on the surface of deposition and thus the technique was shown …

    sheffield-hallam Repository record for Multi-Informative and Specific Detection of Blood in Fingermarks via MALDI-MS Based Strategies (opens in a new tab)

  4. Localized Corrosion Initiation of Steel in CO2 Environments

    … the solubilization of FeCO3. Scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD), and profilometry by infinite focus microscopy (IFM) were used to determine pitting.The results in non-ideal solutions showed that no localized corrosion was …

    ohiolink Repository record for Localized Corrosion Initiation of Steel in CO2 Environments (opens in a new tab)

  5. Microbiologically influenced corrosion of carbon steel caused by a sulfate reducing bacterium

    … were examined by confocal laser scanning microscopy (CLSM), infinite focus microscopy (IFM), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS). Bioactivities in the liquid phase were measured by high-performance liquid chromatography (HPLC) and various biological …

    ohiolink Repository record for Microbiologically influenced corrosion of carbon steel caused by a sulfate reducing bacterium (opens in a new tab)

  6. Investigation of Environmental Effects on Intrinsic and Galvanic Corrosion of Mild Steel Weldment

    … analysis techniques including scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and infinite focus microscopy (IFM) were applied to this study to characterize the surface morphology, identify the chemical composition of corrosion products and quantify the possible localized …

    ohiolink Repository record for Investigation of Environmental Effects on Intrinsic and Galvanic Corrosion of Mild Steel Weldment (opens in a new tab)

  7. Enhancement of the fatigue performance of Ti-6Al-4V implant products.

    … stress state of the surface. This research is focused on an assessment of the role of manufacturing processes on the fatigue performance of hip implants made from a Ti-6Al-4V alloy. The role of surface defects, surface residual stresses and material microstructural properties which influence …

    sheffield-hallam Repository record for Enhancement of the fatigue performance of Ti-6Al-4V implant products. (opens in a new tab)

  8. Micro, meso and macro materials processing using high-speed liquid projectiles

    … of generated samples. Scanning electron microscopy, infinite focus microscopy, 3 D digital microscopy, optical microscopy, 3-D digital profiler, Knoop and Vickers micro hardness testers, nano hardness indenter were used for characterization of generated samples. Full scale …

    njit Repository record for Micro, meso and macro materials processing using high-speed liquid projectiles (opens in a new tab)