Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"infrared light source"”.

  1. Topics And Instrumentation In Chemical Reaction Dynamics

    … more reactive than the ground state. The mid-infrared light source used to excite the methane is an Nd:YAGpumped pulsed optical parametric oscillator/amplifier seeded with a continuous wave laser diode in the near infrared. The OPO/OPA system has an overall quantum efficiency of greater than …

    cornell Repository record for Topics And Instrumentation In Chemical Reaction Dynamics (opens in a new tab)

  2. Design and fabrication of surface textured MEMS for infrared gas sensors

    … of novel MEMS (micro-electro-mechanical systems) infrared gas sensors. It deals with the thermal, electrical, optical and mechanical response for a spectroscopic gas sensor based on MEMS surface textured technologies. An overview of the theories of conventional and novel MEMS infrared gas sensors …

    concordia Download PDF for Design and fabrication of surface textured MEMS for infrared gas sensors (opens in a new tab)

  3. Real-time Image Processing on an FPGA for an Intraoperative Goggle Device

    The emergence of near-infrared dyes for fluorescence imaging has had a tremendous impact in the medical field. In particular, indocyanin green (ICG) has been widely used for assessing tumor margins during intraoperative procedures. Typically, the dye is intravenously injected into the patient, and …

    wustl Repository record for Real-time Image Processing on an FPGA for an Intraoperative Goggle Device (opens in a new tab)

  4. Sparsity Regularization in Diffuse Optical Tomography

    … high contrast imaging modality that uses a near infrared light source. Because the scattering and absorption of a tumor varies significantly from healthy tissue, a reconstructed spatial representation of these parameters serves as tomographic image of a medium. However, the high scatter and …

    clemson Repository record for Sparsity Regularization in Diffuse Optical Tomography (opens in a new tab)

  5. A Multi-Species Single-LED Hazardous Gas Sensor for Commercial Space Applications

    … of interest have absorption features in the mid-infrared range and can be detected with an infrared light source, via the principles of absorption spectroscopy. A non-dispersive infrared (NDIR) sensor that follows these principles has been developed to utilize light-emitting diodes (LEDs) for gas …

    ucf Repository record for A Multi-Species Single-LED Hazardous Gas Sensor for Commercial Space Applications (opens in a new tab)

  6. Thermal Infrared Imaging: Instrumentation and Method Development

    A recently development thermal infrared camera system was improved by designing new components to downsize physical aspect and improve the instrument's performance. A new thermal infrared light source was developed and characterized. It is designed from a custom-made Macor backpiece that holds an …

    south-carolina Repository record for Thermal Infrared Imaging: Instrumentation and Method Development (opens in a new tab)

  7. Measurement of the electrical and optical properties of Thermid polymide

    … using a test system consisting of Keithley 236 Source-Measure Unit. The bulk resistivity decreased to 2 x 10<sup>14</sup>Ω-cm at 200?C. The surface resistivity, 10<sup>15</sup>Ω/0 , and breakdown voltage, 350 V/pm, were also measured. The fixed charge concentration and mobile ion concentration …

    njit Repository record for Measurement of the electrical and optical properties of Thermid polymide (opens in a new tab)

  8. Active and Fast Tunable Plasmonic Metamaterials

    … contributed to studying the interaction between light and matter, specifically focusing on the interaction between the electromagnetic field and free electrons in metals. This interaction can be stimulated by the electric component of light, leading to collective oscillations. In the field of …

    southwales Repository record for Active and Fast Tunable Plasmonic Metamaterials (opens in a new tab) Download PDF for Active and Fast Tunable Plasmonic Metamaterials (opens in a new tab)

  9. Heat generation in irradiated gold nanoparticle solutions for hyperthermia applications

    … GNPs might impact the optical absorption of near infrared (NIR) light. To investigate this, the first part of this study focusses on the fundamentals of how GNP aggregation—a phenomenon that occurs naturally in populations of GNPs but has not been studied with respect to hyperthermia—might be …

    unsw Repository record for Heat generation in irradiated gold nanoparticle solutions for hyperthermia applications (opens in a new tab)

  10. Characterization and Theoretical Study of Mid-infrared Quantum Cascade Lasers

    … potential for emission of long wavelength (mid-infrared to far-infrared); hence, it can be useful for multiple applications. Because of the lack of light source in the mid-infrared range (wavelengths of 3-30 μm), the mid-infrared quantum cascade lasers with high quality radiation are playing …

    waterloo Repository record for Characterization and Theoretical Study of Mid-infrared Quantum Cascade Lasers (opens in a new tab)

  11. InGaAs/InP chip-based mid-infrared optical phased arrays for communications and sensing

    The mid-infrared atmospheric transmission windows (wavelengths ~ 3–5 and 8–14 µm) provide a unique opportunity for low-loss transmission in areas such as thermal imaging, lidar, infrared homing, and line-of-sight communications. Additionally, in comparison to traditional operation in the …

    texas Repository record for InGaAs/InP chip-based mid-infrared optical phased arrays for communications and sensing (opens in a new tab)

  12. Hand Vein: A Distinctive and Non-Contact Biometric Identifier for Humans

    … The patterns can be acquired contactlessly using infrared imaging, making it non-invasive, hygienic, and difficult to falsify. Unlike fingerprints, hand vein recognition does not leave latent prints. It requires a user’s intuitive action for extraction, making it difficult for an imposter to …

    auckland-ms Repository record for Hand Vein: A Distinctive and Non-Contact Biometric Identifier for Humans (opens in a new tab)

  13. Evaluation of Mouse Models of Colorectal Cancer Using Optical Coherence Tomography and Laser Induced Fluorescence Spectroscopy

    … into small diameter endoscopes. Using a near- infrared light source, structural images are generated from index of refraction mismatches with resolutions of 2-15 mm at imaging depths of up to 1.3 mm. In contrast, laser-induced fluorescence (LIF) spectroscopy provides information about …

    arizona-thes Repository record for Evaluation of Mouse Models of Colorectal Cancer Using Optical Coherence Tomography and Laser Induced Fluorescence Spectroscopy (opens in a new tab)

  14. DEVELOPING A BIOSENSOR WITH APPLYING KALMAN FILTER AND NEURAL NETWORK TO ANALYZE DATA FOR FUSARIUM DETECTION

    … by ATR-FTIR spectroscopy, a distinct infrared spectrum of the Chlamydospore was collected. There are two typical infrared wavelengths can be used for Fusarium detection: 1054cm-1 (9.48µm) and 1642cm-1 (6.08µm). Infrared (IR) light is a form of electromagnetic wave which its wavelength …

    sask Repository record for DEVELOPING A BIOSENSOR WITH APPLYING KALMAN FILTER AND NEURAL NETWORK TO ANALYZE DATA FOR FUSARIUM DETECTION (opens in a new tab)

  15. Application of plasmonic devices in spectroscopy and biomedical studies

    … gold membrane emitter that shows a narrowband infrared emission the near-IR and mid-IR wavelength ranges from 2.5 µm to 5.5 µm. The Au-membrane device shows a transmission coefficient as high as 76.8% and an absorption coefficient of 23.1%. The plasmonic gold-membrane device can be used as a …

    iastate Repository record for Application of plasmonic devices in spectroscopy and biomedical studies (opens in a new tab)

  16. High Speed Wavelength Tuning of SGDBR Lasers for Optical Coherence Tomography Applications

    … distance into samples under test with a focused infrared light source. Swept wavelength OCT requires a laser light source that is capable of sweeping its wavelength quickly over the entire wavelength range of the tunable laser. Fast sweeping of the laser's wavelength enables real-time imaging of …

    calpoly Repository record for High Speed Wavelength Tuning of SGDBR Lasers for Optical Coherence Tomography Applications (opens in a new tab)

  17. Vyhodnocení vhodnosti polovodičového zdroje IR záření pro fotoakustický senzor plynů

    Táto práca je zameraná na hodnotenie vhodnosti polovodičového zdroja svetla v strednej infračervenej oblasti pre fotoakustický senzor plynu. Teoretická časť práce bude venovaná známym technikám detekcie plynov, fyzikálnym zákonom, ktoré je potrebné pochopiť, a známym zdrojom infračerveného …

    brno-tech Repository record for Vyhodnocení vhodnosti polovodičového zdroje IR záření pro fotoakustický senzor plynů (opens in a new tab)

  18. COHERENT SPIN TRANSPORT IN NANOWIRE SPIN VALVES AND NOVEL SPINTRONIC DEVICE POSSIBILITIES

    … rate in InSb nanowires can be modulated with infrared light. In the dark, almost all the electrons in the nanowires are in the lowest conduction subband, resulting in near-complete absence of DP relaxation and long spin coherence length. This results in a high resistance state in a spin valve …

    vcu Repository record for COHERENT SPIN TRANSPORT IN NANOWIRE SPIN VALVES AND NOVEL SPINTRONIC DEVICE POSSIBILITIES (opens in a new tab)