Bilateral Ortohogonality Generative Acquisitions Method for Transmit Field Inhomogeneity Correction in Magnetic Resonance Imaging
… and reducing scan time. However, transmit field inhomogeneity of ultra-high field systems, present an obstacle for widespread clinical utilization. In literature, radiofrequency pulse design and multi-acquisition methods with and without parallel transmission systems have been demonstrated for …
-
Noise Estimation, Noise Reduction and Intensity Inhomogeneity Correction in MRI Images of the Brain
Rician noise and intensity inhomogeneity are two common types of image degradation that manifest in the acquisition of magnetic resonance imaging (MRI) system images of the brain. Many noise reduction and intensity inhomogeneity correction algorithms are based on strong parametric assumptions. …
-
Photon dose calculations in inhomogeneous media
… equivalent tissue-air-ratio (ETAR) methods for inhomogeneity corrections. The measured interface dose decreased by 55% for a 5 cm air gap, 5x5 cm² field size and 6 MV photons while only a 10% decrease was calculated by these methods. This points to the need for proper inclusion of electronic …
-
Efficient automatic correction and segmentation based 3D visualization of magnetic resonance images
… algorithms suitable for fast and effective correction and advanced visualization of digital MR image volumes with minimal human operator interaction. This research has resulted in a number of techniques for automated processing of MR image volumes, including a novel MR inhomogeneity …
-
Optimization of Permanent Breast Seed Implant Dosimetry Incorporating Tissue Heterogeneity
… the ease of integration into clinical use. An Inhomogeneity Correction Factor (ICF) is introduced as the ratio of absorbed dose in tissue to that in water medium. ICF is a function of tissue properties and independent of the source structure. The ICF is extracted using CT images and the …
-
SIMULTANEOUS ARTIFACTS CORRECTION AND ACCELERATION FOR CHEMICAL EXCHANGE SATURATION TRANSFER IMAGING VIA DEEP LEARNING
… a deep learning-based Glutamate CEST imaging B0-inhomogeneity correction method (DL-B0GluCEST) to accelerate the total scan time; 2) an improved DL-B0GluCEST method using data acquired from the downfield Z-spectrum only; 3) two deep learning-based methods for estimating B0 inhomogeneities from …
-
Methods for automated analysis of macular OCT data
… subjects: one combining registration and motion correction, and one for simultaneously segmenting the layers across all scans. Third, we develop a method for segmentation of microcystic macular edema, which appear as small, fluid-filled, cystoid spaces within the retina. Our approach again uses …
-
Guanidino Chemical Exchange Saturation Transfer (GuanCEST) Magnetic Resonance Imaging (MRI): Development and Application in Brain
… a post-processing pipeline featuring field inhomogeneity correction, motion correction, and noise removal. We validated our approach using magnetic resonance spectroscopy (MRS), nuclear magnetic resonance (NMR), and further applied it to CO2 challenge and stroke models of mice. Initial …
-
A Monte Carlo study to investigate the dosimetric accuracy in the small field regime
… predict relative dose factors (RDF) and inhomogeneity correction factors (ICF) in inhomogeneous bone and air phantoms. The results were compared with ion chamber measurements and calculations with the TPS BrainSCAN (Brainlab, Germany). After benchmarking our BEAMnrc linear accelerator …
-
X-ray beam modelling in radiotherapy: the effect of lung inhomogeneities
… is described. Currently used photon beam inhomogeneity correction models and their inadequacies are discussed. The methods studied include Batho and Equivalent Tissue-Air-Ratio corrections. For a 10 MV high energy photon beam the mean difference in central axis depth dose in the lung …
-
Design of multidimensional radiofrequency pulses in magnetic resonance imaging
… (FOV) imaging of region-of-interest (ROI), B1 inhomogeneity correction, and simultaneous spatial-spectral selective excitation. While an elegant method known as Shinnar-Le Roux (SLR) method has been developed in one-dimensional RF pulse design, multidimensional RF pulse design remains an open …
-
Deep Learning Methods for Ultra High Field MRI
… Two of the most critical issues at UHF are the inhomogeneity of the transmit radiofrequency (B₁⁺) fields and the reduced SNR in accelerated acquisitions, especially in diffusion MRI (dMRI). This thesis develops deep learning methods that integrate physics-based modeling with data-driven learning …
-
Optimizing VOI brain area segmentation for MRI images in IDAE, The-Integrative-Data-Analysis-Environment-for-Brain-PET
The Integrative Data Analysis Environment (IDAE) is a comprehensive data analysis system for brain research using PET and MRI. The system primarily utilizes FreeSurfer for automatic segmentation of brain regions. The analyses of expensive PET data stall when the freeware yields defective volumes of …
-
Turbulence modeling of stably stratified wall-bounded flows
… a good estimation of the mixing and therefore an inhomogeneity correction must be introduced. It is analytically shown that commonly used homogeneous turbulent Prandtl numbers should be modified for a wall-bounded flow using a correction as (1-z/D), where D is the total flow depth. This work is …
-
Optimalizace systému fluorescenčního zobrazování FluorCam
Cílem diplomové práce je systematická analýza principů měřicích systémů FluorCam, vyvíjených společností Photon Systems Instruments, a fyzikálně-biologických základů fluorescence v biologii rostlin. Práce se zaměřuje na návrh, implementaci a experimentální ověření metodiky pro automatizované …
-
Ανάπτυξη μεθοδολογιών και εργαλείων για την αξιολόγηση, βελτιστοποίηση και διόρθωση των γεωμετρικών παραμορφώσεων και του σήματος εικόνων απεικόνισης μαγνητικού συντονισμού που χρησιμοποιούνται σε εφαρμογές στερεοτακτικής ακτινοχειρουργικής - ακτινοθεραπείας
… such as 3D polymer gel dosimetry. Distortion correction can lead to more precise targeting of possible lesions and optimization of 3D dosimetry to obtain more complete dose information with the highest possible accuracy.After presenting the background knowledge on MRI (chapter 1), the second …
-
Improved Visualization and Quantification for Hyperpolarized 129Xe MRI
… automatic pulmonary vasculature extraction, and inhomogeneity correction of the 129Xe ventilation images. It employs a robust linear binning classification that characterizes the entire ventilation distribution while being grounded in a healthy reference population. This quantification method can …