Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 24 for “"insertion torque"”.

  1. The Accuracy of a Clinician's Assessment of Insertion Torque at Implant Placement

    … implant success, however, has not been proven. Torque measurements acquired during implant placement have been used as a method for assuming implant stability, as they provide valuable information about the local bone quality at the site of placement. The operator's tactile assessment of implant …

    uab Repository record for The Accuracy of a Clinician's Assessment of Insertion Torque at Implant Placement (opens in a new tab)

  2. Effect of a Modified Stepped Osteotomy on the Primary Stability of Dental Implants in Type D4 Bone: A Cadaver Study

    … Class D4 Bone. Significant differences between insertion torques (Ncm) produced by a conventional osteotomy verses a modified stepped osteotomy were examined. Significant differences between Implant Stability Quotients (ISQ) produced by a conventional osteotomy verses a modified stepped …

    wvu Repository record for Effect of a Modified Stepped Osteotomy on the Primary Stability of Dental Implants in Type D4 Bone: A Cadaver Study (opens in a new tab)

  3. Assessment and Interpretation of Dental Implant Stability: A Narrative Review and Prospective Cohort Study

    … over time. Previous studies have suggested that insertion torque, bone density, implant design, and healing duration may influence ISQ values. However, the relationship between healing interval and the change in ISQ that occurs from the time of implant placement to the day of crown insertion …

    penn Repository record for Assessment and Interpretation of Dental Implant Stability: A Narrative Review and Prospective Cohort Study (opens in a new tab)

  4. Stability and Three-Dimensional Analysis of Bone Formation in Longitudinally Fluted Miniscrew Implants

    … loaded with 100g using NiTi coil springs. Insertion torque values were obtained for each MSI that was placed; removal torque values were obtained for 28 MSIs that had been in place for 6 weeks and 20 MSIs that had been in place for 2 weeks. The bone volume fraction surrounding the implant …

    tamu Repository record for Stability and Three-Dimensional Analysis of Bone Formation in Longitudinally Fluted Miniscrew Implants (opens in a new tab)

  5. Clinical outcomes of the Nobel Active dental implant system after one year of loading : a retrospective multicentre analysis

    … The bivariate analysis revealed smoking, insertion torque, anatomic location, previous bone augmentation and immediate loading as significant predictors of marginal bone loss. Significant correlations were observed between insertion torque and bone quality and insertion torque and anatomic …

    ubc Repository record for Clinical outcomes of the Nobel Active dental implant system after one year of loading : a retrospective multicentre analysis (opens in a new tab) Download PDF for Clinical outcomes of the Nobel Active dental implant system after one year of loading : a retrospective multicentre analysis (opens in a new tab)

  6. Comparitive Evaluation of Ridge Expansion and Primary Stability Following Ridge Split, Osseodensification, and Combined Techniques; An in Vitro Porcine Study

    … width change, volumetric expansion, and peak insertion torque were recorded and analyzed using Kruskal Wallis tests. Significant ridge width changes occurred primarily during osteotomy preparation. The combined ridge split plus osseodensification group demonstrated the greatest absolute …

    tamu Repository record for Comparitive Evaluation of Ridge Expansion and Primary Stability Following Ridge Split, Osseodensification, and Combined Techniques; An in Vitro Porcine Study (opens in a new tab) Embargoed until 2028-05-01

  7. Immediate Versus Delayed Loading of Two Implants Supporting A Locator Retained Mandibular Overdenture. A Randomized Controlled Study.

    … and (3) correlation of implant length and insertion torque on RBL. Eligible patients were randomized into test (immediate loading) and control group (delayed loading). Five patients were allocated to control group and seven to the test. All patients had two implants placed. The test group …

    uconn-diss Repository record for Immediate Versus Delayed Loading of Two Implants Supporting A Locator Retained Mandibular Overdenture. A Randomized Controlled Study. (opens in a new tab)

  8. Immediate Versus Delayed Loading of Two Unsplinted Implants Supporting a Locator™ Retained Mandibular Overdenture. A Randomized Controlled Study

    … was the statistical unit. Implant length, insertion torque value (IT), implant failure, prevalence of maintenance visits and prosthetic complications between the groups were also recorded. Results: Thirty subjects 15 in the IL and 15 in the DL groups were available at 12 months evaluation. …

    uconn-diss Repository record for Immediate Versus Delayed Loading of Two Unsplinted Implants Supporting a Locator™ Retained Mandibular Overdenture. A Randomized Controlled Study (opens in a new tab)

  9. Surgical Factors Related to Peri-Implant Diseases

    … spacing to adjacent teeth or implants, insertion torque, and surgical approach (single vs. two-stage). Additional implant-related and restorative data was recorded, but this study focuses exclusively on surgical factors. Results Peri-implant disease was present in two-thirds of implants, …

    penn Repository record for Surgical Factors Related to Peri-Implant Diseases (opens in a new tab)

  10. Immediate Loading Of 4 Guided Implants Supporting A Maxillary Overdenture Using A Novaloc Retention System

    … Switzerland) immediately following surgery if insertion torque (IT) reached 20 N/cm or above. The primary outcome variable was the radiographic bone level change at 6- and 12-months following implant placement. Secondary outcome variables were peri-implant soft tissue assessment (PD, KT, BoP, …

    wvu Repository record for Immediate Loading Of 4 Guided Implants Supporting A Maxillary Overdenture Using A Novaloc Retention System (opens in a new tab)

  11. Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results

    … Initial implant parameters reported include insertion torque value (Ncm) and resonance frequency measure (ISQ) at implant placement. Initial mean torque value for all implants was 36.5 Ncm, and initial mean ISQ value was 79. Immediate implants demonstrated a mean torque value of 37.9 Ncm and …

    umn Repository record for Clinical Performance and Outcomes of a Platform Switching, Multi-Level Surface Implant System: A Prospective Clinical Study/Surgical Results (opens in a new tab)

  12. Stability of implants placed at sites treated with bone allograft

    … gender, Type 2 diabetes, smoking, implant type, insertion torque, buccal bony dehiscence, surgeon’s level of experience, or whether the site had a history of lateral ridge augmentation, socket preservation, or sinus lifting. Conclusions: Implant stability, as measured using the Osstell ISQ …

    ubc Repository record for Stability of implants placed at sites treated with bone allograft (opens in a new tab) Download PDF for Stability of implants placed at sites treated with bone allograft (opens in a new tab)

  13. ASSESSMENT OF PERI-IMPLANT BONE MICROARCHITECTURE IN D4 BONE: AN EX VIVO MICROCT ANALYSIS

    … implant designs on primary stability, peak insertion torque (PIT), implant stability quotient (ISQ), and peri-implant bone microarchitecture in low-density bone (D4). The investigation focused on three Straumann implant systems: Bone Level Tapered (BLT), Bone Level X (BLX), and Tissue Level …

    temple Repository record for ASSESSMENT OF PERI-IMPLANT BONE MICROARCHITECTURE IN D4 BONE: AN EX VIVO MICROCT ANALYSIS (opens in a new tab)

  14. Correlation Of Preoperative Analysis Of Cbct Gray Value With Implant Primary Stability

    … stability of dental implants by measuring insertion torque value (ITV) and Resonance Frequency Analysis (ISQ). Materials and Methods: Thirty-eight patients planned to receive a total of 102 dental implants (Straumann Bone Level Tapered) were enrolled in the study. At time of implant …

    uab Repository record for Correlation Of Preoperative Analysis Of Cbct Gray Value With Implant Primary Stability (opens in a new tab)

  15. Primary Fixation and Anchorage of Dental Implants in Bone Surrogate

    … engagement between bone and implant during insertion) and primary fixation (mechanical engagement under loading) of dental implants have been recommended for positive clinical outcomes. Rigid polyurethane (PU) foam as standard bone surrogate material has been widely used in preclinical …

    queens Repository record for Primary Fixation and Anchorage of Dental Implants in Bone Surrogate (opens in a new tab)

  16. The elaboration of a novel TAD design and its comparison to an industrial design

    … load, using the Instron 5566A to measure the insertion torques and removal torques. Torque ratios were then calculated. Using the same Instron machine with TADs fully inserted in the artificial bone (2 per design per angle), pull-out tests were performed at angles of 0° / 30° / 60° / 90°. The …

    bu Repository record for The elaboration of a novel TAD design and its comparison to an industrial design (opens in a new tab)

  17. Mechanische Grundlagen für die Entwicklung eines metallfreien Implantatsystems auf der Basis von Polyetheretherketon (PEEK)

    Konventionelle Dentalimplantate auf Titan-Basis können mit verschiedenen Problemen behaftet sein. Einerseits gibt es Patienten mit nachgewiesener Titanüberempfindlichkeit, andererseits stehen Titanimplantate wegen des hohen E-Moduls von Titan (110 GPa) im Verdacht, den periimplantären Knochen …

    fu-berlin Repository record for Mechanische Grundlagen für die Entwicklung eines metallfreien Implantatsystems auf der Basis von Polyetheretherketon (PEEK) (opens in a new tab)

  18. Untersuchung zur Primärstabilität zweier dentaler Implantatsysteme mittels Resonanz-Frequenz-Analyse in vivo

    … deutlichen Drehmomentanstieg kurz vor dem Insertionsende beim Ankylos®-System im Gegensatz zu den fast linearen Kurven ohne Wertanstieg beim Camlog®-System deuten auf dessen höhere Primärstabilität hin. Insgesamt konnte keine Korrelation zwischen den Drehmomentwerten und der RFA …

    fu-berlin Repository record for Untersuchung zur Primärstabilität zweier dentaler Implantatsysteme mittels Resonanz-Frequenz-Analyse in vivo (opens in a new tab)

Page 1 of 2