Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 14 of 14 for “"insole design"”
-
Adaptive insole design to prevent foot ulcers in diabetic neuropathy patients
… investigates whether an adaptive multilayer insole can sense high plantar pressure and redistribute load through soft robotic pneumatic actuation to prevent diabetic foot ulcers. The prototype includes a cushioning layer, a 16-zone force-sensitive resistor array, a McKibben pneumatic …
-
Measuring human foot-transmitted vibration exposure in mining: a field study and prototype measurement insole design
… pathways due to changes in equipment design, introducing new and insufficiently characterized health risks. This thesis investigates foot-transmitted vibration (FTV) exposure among standing operators and addresses limitations in current measurement approaches through both field study …
-
Development of a Posture-Specific Insole Design Framework for Roofing Construction Workers based on Plantar-Pressure Biomechanics
… safety footwear continues to rely on generic insoles that are primarily designed for general walking and comfort rather than the unique biomechanical and environmental demands of roofing work. This dissertation develops an evidence-based pathway toward a roofer-specific insole through three …
-
An investigation into the effect of customised insoles on plantar pressures in people with diabetes
… Consequently, patients are often prescribed insoles designed to reduce pressure. New technologies, such as plantar pressure measurement devices and 3D foot scanners, have the potential to improve insole design. However, it is not clear to what extent such technologies are currently being used …
-
An investigation into the effect of customised insoles on plantar pressures in people with diabetes
… Consequently, patients are often prescribed insoles designed to reduce pressure. New technologies, such as plantar pressure measurement devices and 3D foot scanners, have the potential to improve insole design. However, it is not clear to what extent such technologies are currently being used …
-
Female-Centric Soccer Gear Informed by Biomechanics and Design Insights
… insights from athlete-centered ethnographic design research. This project exists at the intersection of quantitative biomechanics data and qualitative design insights tailored to female athlete needs. The first section asks, how have previous biomechanics studies evaluated soccer footwear …
-
Extended Biomechanical Model of the Ankle-Foot Complex: Incorporation of Muscles and Ligaments
… Aladyn project, which aims at developing custom insoles with dynamic structures through 3D printing, there is need to model this complexity for extending the level of scientific evidenced-based insole design using multi-body dynamic simulations. In this work, an extended musculoskeletal foot …
-
Development of an Industrial Test Platform for Foot Health Device and Footwear Testing
… in peak andaverage plantar pressures due to insole products (compared to a shoe-only condition).However, there was no significant difference between the insole products when compared toa neutral control insole. This challenges whether the specific product designs add anyperformance value …
-
Development of an Industrial Test Platform for Foot Health Device and Footwear Testing
… in peak andaverage plantar pressures due to insole products (compared to a shoe-only condition).However, there was no significant difference between the insole products when compared toa neutral control insole. This challenges whether the specific product designs add anyperformance value …
-
Podiatrists’ and orthotists’ views and experiences of using plantar pressure measurement in the assessment and treatment of diabetic foot syndrome
… pressure assessment (PPA) to guide footwear and insole design and modification in people with diabetic foot disease, a systematic review was undertaken. Although the current evidence supports the use of PPA in diabetic foot management, the implementation of the technology in a clinical setting …
-
Podiatrists’ and orthotists’ views and experiences of using plantar pressure measurement in the assessment and treatment of diabetic foot syndrome
… pressure assessment (PPA) to guide footwear and insole design and modification in people with diabetic foot disease, a systematic review was undertaken. Although the current evidence supports the use of PPA in diabetic foot management, the implementation of the technology in a clinical setting …
-
Towards shock absorbing hyperelastic metamaterial design
… tools to be used in the analysis and design of shock absorbing metamaterials for industrial applications. The research is organized into two complementary chapters. The first part focuses on the computational modeling of shock propagation in hyperelastic materials, emphasizing its …
-
Insoles to ease plantar pressure in people with diabetes and peripheral neuropathy: a feasibility randomised controlled study with embedded qualitative component
Collings, R. Insoles to ease plantar pressure in people with diabetes and peripheral neuropathy: a feasibility randomised controlled study with embedded qualitative component. Background: Diabetic foot ulceration is a devastating complication of diabetic foot disease. Therapeutic footwear and …
-
The Design and Manufacture of Symptom and Sport Specific Insoles
… of the art manufacturing methods for bespoke insoles prescribed and modelled in a CAD environment. However, the limitations of both these manufacturing methods relate to the materials that can be processed, which becomes problematic when manufacturing soft or semi-rigid orthoses. Hence an …