Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 408 for “"instron"”.

  1. Comparison of two fusible webs with two hand sewn methods of hemming 100 percent double knit polyester

    … the same methods, were tested objectively on the Instron. All specimens were evaluated after zero, one, five, 10 and 20 launderings. Statistical analysis was done through the use of the Two-Way Classic fication Analysis of Variance and multiple comparison procedures (Tukey, 1953). Major findings …

    vt Repository record for Comparison of two fusible webs with two hand sewn methods of hemming 100 percent double knit polyester (opens in a new tab)

  2. In Vivo and Ex Vivo Hysteresis of Sheep Medial Gastrocnemius and Plantaris Tendons

    … the same in vivo loading conditions using an Instron machine. We directly accessed medial gastrocnemius (MG) in vivo muscle forces and tendon lengths using a buckle-type force transducer and a saline-filled silastic tube length sensor, respectively. The Instron recorded the ex vivo tendon …

    calgary Repository record for In Vivo and Ex Vivo Hysteresis of Sheep Medial Gastrocnemius and Plantaris Tendons (opens in a new tab)

  3. A comparison of four objective measures of beef tenderness

    … Tenderometer (AT), Warner-Bratzler Shear (WB), Instron Universal Testing Instrument (Instron) and subjective evaluations.</p> <p>Muscles used came from 35 beef animals, five from each of seven mating types: Charolais-Hereford (CH) dams bred to Hereford (H) or Charolais (C) bulls, H dams bred to …

    utk-theses Repository record for A comparison of four objective measures of beef tenderness (opens in a new tab)

  4. Tenderness of beef muscle measured by shear-stress

    … shearing cells were Installed in an Instron Universal Testing Instrument (Instron). Reproducibility of the two devices was established by the use of frankfurters as a "standard" meat sample. Five beef muscles, the Longissimus dorsi (ribeye), L. dorsi (loin), Semimembranosus, …

    ut-knoxville Repository record for Tenderness of beef muscle measured by shear-stress (opens in a new tab)

  5. Comparison of Mechanical Properties of Latex and Latex-Free Elastics

    … and extension at fracture were measured using an Instron Universal testing machine. In the second set of tests, the maximum load, 2 minute load, load relaxation and relaxation energy were measured with the Instron as well. Specimens were tested both dry and wet in a simulated oral environment. …

    marquette Repository record for Comparison of Mechanical Properties of Latex and Latex-Free Elastics (opens in a new tab)

  6. Effect of ceramic density and curing pressure on properties of a resin infused alumina

    … Biaxial flexural strength was measured using an Instron Universal Testing machine at 0.5 mm/min crosshead speed. Surface roughness was measured with a Mitotoyu profilometer. Hardness was measured using a Vickers hardness test using Instron-produced indentations at 15 newton load for 30 seconds. …

    bu Repository record for Effect of ceramic density and curing pressure on properties of a resin infused alumina (opens in a new tab)

  7. Identification of dynamic properties of materials for the nuclear waste package

    … MTS Axial/Torsion Material testing system and Instron Dynatup impact test machine. Third, fixtures for tensile testing using two machines were designed and manufactured. Fourth, experimental procedures for testing of materials are proposed for the MTS and Instron testing machines. Finally, …

    unlv Repository record for Identification of dynamic properties of materials for the nuclear waste package (opens in a new tab) Download PDF for Identification of dynamic properties of materials for the nuclear waste package (opens in a new tab)

  8. The Evaluation of Usefulness of the FEA and Relationship Between Trabecular Microstructural and Biomechanical Properties In Human Femoral Head

    … yield stress and Young's modulus from FEA and Instron system were 13.04 ㎫ and 1.30 ㎬, 13.06 ㎫ and 0.11 ㎬, respectively. Pearson correlations between Of the morphometry indices, Tb.Th, Tb.Sp, S/V, BV/TV and Tb.N were significantly correlated with from FEA, while only BV/TV and Tb.N were …

    ajou Repository record for The Evaluation of Usefulness of the FEA and Relationship Between Trabecular Microstructural and Biomechanical Properties In Human Femoral Head (opens in a new tab) Embargoed until 9999-12-31

  9. Chemical, physical and sensory characteristics of ground and comminuted pork with various fat levels and corn milling secondary products

    … were analyzed for proximate composition, color, Instron compression and cooking loss. Broiled pork patties containing zein were evaluated by a sensory panel;Dry- and wet-milled germ flour addition at the 5% level decreased cooking losses, 9 and 7.5%, respectively, when compared to control …

    iastate Repository record for Chemical, physical and sensory characteristics of ground and comminuted pork with various fat levels and corn milling secondary products (opens in a new tab)

  10. Quality changes of aquacultured hybrid striped bass fillet meat resulting from reduction of post-harvest metabolism

    … count, pH determination, texture measurements (Instron), color measurements (L* a* b* scale) and sensory panel evaluations of cooked portions for appearance, taste, odor and texture. Fillets of the cooled water treatment group had the highest pH and were significantly less firm (Instron). Log …

    vt Repository record for Quality changes of aquacultured hybrid striped bass fillet meat resulting from reduction of post-harvest metabolism (opens in a new tab)

  11. Integrating micro-CT and computational bone mechanics to evaluate bone treatment outcomes

    … on a 3D printed bone sample, which underwent an Instron compression test. This pipeline was evaluated as part of three clinical studies. The first, a large scale human clinical trial on the effects of low-dose fluoride therapy in postmenopausal women. Second, a whey protein diet in a murine model …

    auckland-ms Repository record for Integrating micro-CT and computational bone mechanics to evaluate bone treatment outcomes (opens in a new tab)

  12. Resistencia al cizallamiento e indice adhesivo remanente (ARI) de dos cementos ortodónticos fotopolimerizables antes y después del termociclado

    … cizallamiento con la máquina de ensayo universal Instron® (3382, Instron Corp., Canton, Mass) a una velocidad de 0.5mm/min y se registraron los datos en megapascales (MPa). Después de la prueba de cizallamiento, fue registrado el índice ARI con el Microscopio Digital Dino-Lite AM4515T8 Edge a 40x. …

    upc-peru Repository record for Resistencia al cizallamiento e indice adhesivo remanente (ARI) de dos cementos ortodónticos fotopolimerizables antes y después del termociclado (opens in a new tab)

  13. Tensile Bond Strength of Stainless Steel Orthodontic Brackets on Microabraded Teeth

    … then loaded to failure in the tensile mode of an Instron testing machine (Instron Corp., Canton, Mass.). A ·stress-breaking apparatus was utilized to minimize all forces other than tensile. The data was statistically analyzed using one-way analysis of variance at the 0.05 level. No statistically …

    iupui Repository record for Tensile Bond Strength of Stainless Steel Orthodontic Brackets on Microabraded Teeth (opens in a new tab)

  14. Tensile bond strength of stainless steel orthodontic brackets on microabraded teeth

    … then loaded to failure in the tensile mode of an Instron testing machine (Instron Corp., Canton, Mass.). A stress-breaking apparatus was utilized to minimize all forces other than tensile. The data was statistically analyzed using one-way analysis of variance at the 0.05 level. No statistically …

    iupui Repository record for Tensile bond strength of stainless steel orthodontic brackets on microabraded teeth (opens in a new tab)

  15. Compressibility Measurement and Modeling to Optimize Flow Simulation of Vacuum Infusion Processing for Composite Materials

    … be directly equal to compressive forces of the Instron when resin is present in the system. The relationship between Instron, resin and compaction pressures is defined. The compression study was used to validate previously developed flow simulation models. Resin pressures are critical to …

    byu Repository record for Compressibility Measurement and Modeling to Optimize Flow Simulation of Vacuum Infusion Processing for Composite Materials (opens in a new tab) Download PDF for Compressibility Measurement and Modeling to Optimize Flow Simulation of Vacuum Infusion Processing for Composite Materials (opens in a new tab)

  16. Effect of impingement oven precookery and reheating on physical, chemical and sensory characteristics of beef top loin steak

    … were determined. A puncture probe attached to an Instron Universal Testing Machine was used to determine mechanical parameters of hardness, cohesiveness and chewiness. Warner-Bratzler shear force values were also determined. Chemical analyses on the reheated steaks included chemical moisture and …

    ut-knoxville Repository record for Effect of impingement oven precookery and reheating on physical, chemical and sensory characteristics of beef top loin steak (opens in a new tab)

  17. The Effect of Plastic Deformation on a Series of Thin Magnetic Films

    … and (2) straining the sample laterally using an Instron 5566 materials tester. The magnetic properties were measured after each straining session via VSM using a sample holder developed for these experiments, which would allow the characterization. The quantity of plastic deformation introduced …

    texas-state Repository record for The Effect of Plastic Deformation on a Series of Thin Magnetic Films (opens in a new tab)

  18. Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire

    … the weld was made. Resistances were compared to Instron 5900 tensile maximum break load (KgF). Use of optical microscopy and Scanning Electron Microscopy (SEM) revealed microstructural reduction of void size at the sample fracture surface (1-.5 µm). Literature suggested the existence of …

    calpoly Repository record for Effect of Oxidation on Weld Strengthof Dissimilar Resistance Weld Interface Between 304 Stainless Steeland Near Equiatomic Austenitic Nitinol Guide Wire (opens in a new tab)

Page 1 of 21