Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 93 for “"integrating sphere"”.

  1. Double Integrating Sphere Characterization of PVA-Cryogels

    … including its optical characteristics. A double integrating sphere system was used in conjunction with the Inverse Adding Doubling (IAD) algorithm to characterize the optical properties of thin slab samples. The setup was evaluated using liquid phantoms. Liquid emulsion and food colouring were …

    mcmaster Repository record for Double Integrating Sphere Characterization of PVA-Cryogels (opens in a new tab)

  2. Linearity and spectral characteristics of integrating sphere sources

    … irradiance levels required involves the use of integrating spheres as attenuation devices. Aperture wheels are used with these sources. Questions concerning linearity performance and spectral qualities arise when these types of sources are employed. This study addresses these issues by examining …

    ut-knoxville Repository record for Linearity and spectral characteristics of integrating sphere sources (opens in a new tab)

  3. Spatial and Spectral Corrections for Integrating Sphere Photometry and Radiometry

    … as luminous flux, which is often measured using integrating sphere photometers. These instruments consist of a hollow sphere and a detector whose output signal is proportional to the luminous flux emitted by the device under test. Non-ideal characteristics of photometers and integrating spheres …

    aalto Repository record for Spatial and Spectral Corrections for Integrating Sphere Photometry and Radiometry (opens in a new tab)

  4. Monitoring Laser Material Processing by Simultaneous Inline Coherent Imaging and Integrating Sphere Radiometry

    … of the material. In this work, we combine integrating sphere radiometry (ISR) and inline coherent imaging (ICI) to simultaneously measure time-resolved absorptance and vapour depression depth during stationary, high-irradiance laser illumination of a metal (AISI 316 stainless steel). This …

    queens Repository record for Monitoring Laser Material Processing by Simultaneous Inline Coherent Imaging and Integrating Sphere Radiometry (opens in a new tab)

  5. Upgrading a Broad Area Illuminating Integrating Sphere and Solar Transmittance Measurement of a Sheer Blind

    … was measured using a Broad Area Illuminating Integrating Sphere (BAI-IS). More specifically, the spectral directional-hemispherical transmittance was measured in the wavelength range of 0.4 µm to 2.0 µm. A “sheer blind” consists of soft fabric vanes, similar to a venetian blind, suspended …

    waterloo Repository record for Upgrading a Broad Area Illuminating Integrating Sphere and Solar Transmittance Measurement of a Sheer Blind (opens in a new tab)

  6. Integrating sphere-based spectrally constrained total diffuse reflectance for in vivo quantification of hemoglobin in skin

    … diffuse reflectance spectra obtained with an integrating sphere-based system. A low cost integrating sphere-based system was designed, constructed, and characterized to yield accurate total diffuse reflectance spectra. The system was first used with an absorbance-based erythema index to …

    mcmaster Repository record for Integrating sphere-based spectrally constrained total diffuse reflectance for in vivo quantification of hemoglobin in skin (opens in a new tab)

  7. Shedding Light on Laser-Metal Interactions: In situ Monitoring with Inline Coherent Imaging and Integrating Sphere Radiometry

    … By employing inline coherent imaging (ICI) and integrating sphere radiometry (ISR) at high imaging rates (200 kHz), the measurements reveal the time-dependent cavity-enhanced absorptance within these keyholes. The results show that processing in an argon-rich environment, as opposed to air, …

    queens Repository record for Shedding Light on Laser-Metal Interactions: In situ Monitoring with Inline Coherent Imaging and Integrating Sphere Radiometry (opens in a new tab)

  8. Quantifying Chromophore Concentration in Tissue Simulating Phantoms Using an Optical Detection System Based on an Integrating Sphere

    <p> An integrating sphere system has been developed to study the optical properties of biological tissues non-invasively, over a broad spectral range with the ultimate goal of quantifying erythema resulting from external beam radiotherapy. An empirical model was defined to calculate the absorption …

    mcmaster Repository record for Quantifying Chromophore Concentration in Tissue Simulating Phantoms Using an Optical Detection System Based on an Integrating Sphere (opens in a new tab)

  9. The design, construction, and calibration of a spectral diffuse/global irradiance meter

    … in this dissertation. I develop general integrating sphere theory, modeling methods, and describe the resultant computer model. The model results agreed with theory to better than 1% for a simple unbaffled integrating sphere. I applied the model to design an interior baffled integrating …

    arizona-thes Repository record for The design, construction, and calibration of a spectral diffuse/global irradiance meter (opens in a new tab)

  10. An investigation into the replacement of mercury by indium iodide or tin halides in high-intensity discharge lamps

    … The spectra of the lamps were measured in an integrating sphere and their energy balances were determined. The spectra showed that indium iodide emits a broad continuum in the visible and infrared part of the spectrum. There was also a complete absence of ultraviolet radiation. The plasma …

    eindhoven Repository record for An investigation into the replacement of mercury by indium iodide or tin halides in high-intensity discharge lamps (opens in a new tab) Download PDF for An investigation into the replacement of mercury by indium iodide or tin halides in high-intensity discharge lamps (opens in a new tab)

  11. Development and understanding of a plasma-assisted atomic layer deposition process for silicon nitride

    … The spectra of the lamps were measured in an integrating sphere and their energy balances were determined. The spectra showed that indium iodide emits a broad continuum in the visible and infrared part of the spectrum. There was also a complete absence of ultraviolet radiation. The plasma …

    eindhoven Repository record for Development and understanding of a plasma-assisted atomic layer deposition process for silicon nitride (opens in a new tab) Download PDF for Development and understanding of a plasma-assisted atomic layer deposition process for silicon nitride (opens in a new tab)

  12. New measurement standards and methods for photometry and radiometry

    … reference photometer, a spectroradiometer and an integrating-sphere light source. The realization of the unit of luminous flux (lumen) is based on a 1.65-m integrating sphere instead of a goniophotometer. This is one of the first realizations of lumen in the world using the absolute integrating …

    aalto Repository record for New measurement standards and methods for photometry and radiometry (opens in a new tab)

  13. Hyper-Spectral Sensor Calibration Extrapolated from Multi-Spectral Measurements

    … solution to the attenuation of flux within an integrating sphere, the best laboratory source of non-directional radiance for numerous radiometric applications, is given. Relative component attenuations due to integrating sphere coating, exit port escape, and atmospheric absorption are derived …

    arizona-thes Repository record for Hyper-Spectral Sensor Calibration Extrapolated from Multi-Spectral Measurements (opens in a new tab)

  14. Leaf Epidermal Transmittance of Ultraviolet Radiation and Its Implication for Plant Sensitivity to Ultraviolet-Radiation Injury

    … isolated and examined with a spectroradiometer/integrating sphere for transmittance. A survey of 25 species exposed to natural insolation was conducted. Although the species differed in life form, habitat type, and epidermal characteristics, epidermal transmittance was generally less than 10%. …

    utahstate Repository record for Leaf Epidermal Transmittance of Ultraviolet Radiation and Its Implication for Plant Sensitivity to Ultraviolet-Radiation Injury (opens in a new tab)

Page 1 of 5