Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 87 for “"inter observer variability"”.

  1. Deep Learning Frameworks to Improve Inter-Observer Variability in CT Measurement of Solid Tumor

    … growing number of research studies have reported inter-observer variability in computed tomographic (CT) measurements among radiologists, there are very few interventional studies performed to reduce the variability. Furthermore, it remains unclear whether use of conventional statistical measures …

    clemson Repository record for Deep Learning Frameworks to Improve Inter-Observer Variability in CT Measurement of Solid Tumor (opens in a new tab)

  2. Development and evaluation of the virtual pathology slide: a new tool for understanding inter-observer variability in diagnostic microscopy

    … the examination of pathology slides via the Internet or CD-Rom. A novel feature of the VPS is the ability to record the migratory traces (image viewed and magnification) of pathologists examinations on a remote relational database located in Dublin City University. In order to evaluate the …

    dcu Download PDF for Development and evaluation of the virtual pathology slide: a new tool for understanding inter-observer variability in diagnostic microscopy (opens in a new tab)

  3. Auto-Delineation of Oropharyngeal Clinical Target Volumes Using Deep Learning Techniques

    … there are several reports of significant inter-observer variability when delineating these target volumes for head and neck cancers making this variability one of the largest sources of uncertainty in head and neck radiation therapy. The purpose of this study was to develop algorithms to …

    uthsc Repository record for Auto-Delineation of Oropharyngeal Clinical Target Volumes Using Deep Learning Techniques (opens in a new tab)

  4. Towards MRI guided radiotherapy for lung cancer

    … An assessment of a radiologist-led workshop on inter-observer variability in volume delineation showed no significant improvement. To assess the potential benefit of MRI for lung RT, a prospective clinical trial was conducted. Inter-observer variability on target volume delineation for T2 MRI …

    unsw Repository record for Towards MRI guided radiotherapy for lung cancer (opens in a new tab)

  5. Automated thyroid ultrasound assessment : clinically aligned segmentation, TI-RADS risk stratification, and reader variability analysis

    … data, variable ultrasound image quality, and inter-observer variability in image acquisition, contouri,ng and interpretation. This thesis investigates automated thyroid ultrasound assessment from a clinically aligned perspective. First, public thyroid ultrasound datasets are benchmarked for …

    ubc Repository record for Automated thyroid ultrasound assessment : clinically aligned segmentation, TI-RADS risk stratification, and reader variability analysis (opens in a new tab) Download PDF for Automated thyroid ultrasound assessment : clinically aligned segmentation, TI-RADS risk stratification, and reader variability analysis (opens in a new tab)

  6. Improving outcome assessment for clinical trials in stroke

    … efficacy of the scale is potentially limited by inter-observer variability. Using a “mock” clinical trial design I demonstrate that inter-observer mRS variability in contemporary practice is moderate (k=0.57). Adding these data to systematic review of published data, confirms an overall moderate …

    glasgow Download PDF for Improving outcome assessment for clinical trials in stroke (opens in a new tab)

  7. Development of native and contrast enhanced magnetic resonance imaging for the characterization of cardiovascular disease

    … I found this improved blood suppression and inter-observer variability of scar size measurement and allowed imaging at an earlier time point compared to IR imaging for both ventricular and atrial wall scar.<br/>For ventricular scar, I also found improved expert confidence and inter-observer …

    kings Repository record for Development of native and contrast enhanced magnetic resonance imaging for the characterization of cardiovascular disease (opens in a new tab) Download PDF for Development of native and contrast enhanced magnetic resonance imaging for the characterization of cardiovascular disease (opens in a new tab)

  8. Evaluación clínica del uso de la inteligencia artificial, tiroglobulina ultrasensible y terapia supresiva de TSH en el carcinoma diferenciado de tiroides

    … thyroid nodules, although it presents high inter-observer variability. Artificial intelligence (AI) has improved diagnostic accuracy, reducing unnecessary biopsies and increasing agreement between observers. The main objective of this work was to evaluate and validate new tools to optimize …

    valladolid Repository record for Evaluación clínica del uso de la inteligencia artificial, tiroglobulina ultrasensible y terapia supresiva de TSH en el carcinoma diferenciado de tiroides (opens in a new tab)

  9. A Comparison of Two Hue Scaling Methods

    … categories. The two methods were compared for 29 observers. Settings on both tasks were comparable though the similarity ratings showed weaker categorical bias and less inter-observer variability. The concordance suggests that the functions measured by the two paradigms reflect properties of color …

    unr Repository record for A Comparison of Two Hue Scaling Methods (opens in a new tab)

  10. Studie zur Evaluation der Reproduzierbarkeit und Objektivität zweier Schmerzskalen bei der Katze

    … „Composite Pain Scale“, CPS, und eine interaktive visuelle analoge Skala „Dynamic and Interactive Visual Analogue Scale“, DIVAS, auf ihre Reproduzierbarkeit und Variabilität zwischen verschiedenen Beobachtern überprüft. Anhand von Videoaufnahmen wurden 21 Katzen nach einer …

    zurich Repository record for Studie zur Evaluation der Reproduzierbarkeit und Objektivität zweier Schmerzskalen bei der Katze (opens in a new tab)

  11. The role of colour in facial age estimation

    … biases the perception of age and/or affects inter-observer variability in age judgements. We found that the same face tended to be judged as younger with increased RG contrast compared to decreased RG contrast, suggesting that RG contrast directly affects age perception. Inter-observer …

    unsw Repository record for The role of colour in facial age estimation (opens in a new tab)

  12. Computer-aided detection of polyps in CT colonography

    … reader, this polyp detection scheme reduces interpretation time and decreases inter-observer variability among different radiologists. Polyp candidates are first identified using shape index and curvedness, subsequently filtered by a simple set of rules, before being subjected to linear …

    nus Repository record for Computer-aided detection of polyps in CT colonography (opens in a new tab) Download file for Computer-aided detection of polyps in CT colonography (opens in a new tab)

  13. Computational Modeling for Abnormal Brain Tissue Segmentation, Brain Tumor Tracking, and Grading

    … hand, brain strokes occur due to the sudden interruption of the blood supply which damages the normal brain tissues and frequently causes death or persistent disability. Clinical management of these brain tumors and stroke lesions critically depends on robust quantitative analysis using …

    odu Repository record for Computational Modeling for Abnormal Brain Tissue Segmentation, Brain Tumor Tracking, and Grading (opens in a new tab)

  14. Machine learning applications in medical imaging for early diagnosis of cardiovascular diseases

    … rely on subjective evaluations that are prone to inter-observer variability. A revolutionary method for improving diagnostic automation, efficiency, and accuracy is the incorporation of machine learning (ML) into medical imaging. Large amounts of imaging data can be analyzed using ML algorithms, …

    bu Repository record for Machine learning applications in medical imaging for early diagnosis of cardiovascular diseases (opens in a new tab)

  15. Multivariate classification and Fourier-Transform Mid- Infrared Spectroscopy (FT-MIR) in cancer prostate tissue

    … easy proceedings, independence of intra- and inter-observer variability, and high sensitivity and specificity; in comparison to traditional techniques (which suffer with operator-dependence, high intra- and inter-observer variability, high time consuming, difficult preparation and lower …

    brazil-ufrn Repository record for Multivariate classification and Fourier-Transform Mid- Infrared Spectroscopy (FT-MIR) in cancer prostate tissue (opens in a new tab)

  16. The role of feature-tracking cardiovascular magnetic resonance in optimising response to cardiac resynchronisation therapy

    … patients demonstrated good intra- and inter-observer variability, and reasonable agreement compared with MT. In a retrospective observational study of CRT recipients, greater baseline dyssynchrony did not predict LV reverse remodelling (LVRR) or symptomatic response at 6 months, but low …

    birmingham Download PDF for The role of feature-tracking cardiovascular magnetic resonance in optimising response to cardiac resynchronisation therapy (opens in a new tab)

  17. Predicting Femoral Geometry from Anatomical Features

    … for which an acquisition protocol and user-interface was devised to minimize inter-observer variability. Both the data and methods used to construct the atlas are discussed as well generating shapes from features. The reconstructions accuracy was comparable to, albeit lower than, competing …

    queens Repository record for Predicting Femoral Geometry from Anatomical Features (opens in a new tab)

  18. Cone beam computed tomographic simulation of panoramic radiology : third molar assessment and mandibular canal.

    … to be present or absent by two independent observers. Each observer will also utilize the CBVCT cross sectional analysis of the mandible, measure the distance in mm, the mandibular canal to the closest part of the mandibular third molar tooth. With these observations we will be able to …

    louisville Repository record for Cone beam computed tomographic simulation of panoramic radiology : third molar assessment and mandibular canal. (opens in a new tab)

  19. Long term facial alveolar bone changes associated with endosseous implants in the anterior maxilla.

    … each implant was measured at seven levels by two observers independently and means and standard deviations calculated. Inter-observer variability was determined using the Dahlberg formula. The percentage of sites with no FABr at each level was compared between sex, implant type and location using …

    louisville Repository record for Long term facial alveolar bone changes associated with endosseous implants in the anterior maxilla. (opens in a new tab)

  20. Impacto de un curso teórico de mamografía en la categorización de microcalcificaciones de acuerdo al BI-RADS 4ed

    … descriptors. Also we calculate the intra and inter-observer variation using Cohen’s kappa, sensibility and specificity. Results: For calcifications with high probability of malignancy (pleomorphic and fine linear), a PPV of 41 and 40% was calculated, with a mild increase comparing with prior …

    rosario Repository record for Impacto de un curso teórico de mamografía en la categorización de microcalcificaciones de acuerdo al BI-RADS 4ed (opens in a new tab) Restricted access

Page 1 of 5