Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 81 for “"interaction point"”.

  1. Development of interaction point feedback systems for CERN’s Future Circular Lepton Collider

    … control of the relative beam position at the interaction points (IPs). Dynamic perturbations arising from ground motion, magnet vibrations and beam–beam interactions introduce orbit fluctuations that reduce effective luminosity and require active stabilisation. Fast beam-based feedback systems …

    oxford Repository record for Development of interaction point feedback systems for CERN’s Future Circular Lepton Collider (opens in a new tab)

  2. The Interaction Point Collision Feedback System at the International Linear Collider and its sensitivity to expected electromagnetic backgrounds

    An Interaction Point Collision Feedback System is necessary to achieve design luminosity at the future International Linear Collider (ILC). This is proposed to include a stripline beam position monitor (BPM) positioned 3 m from the Interaction Point (IP). The BPM is required to be able to measure …

    oxford Repository record for The Interaction Point Collision Feedback System at the International Linear Collider and its sensitivity to expected electromagnetic backgrounds (opens in a new tab)

  3. Development of a readout system for the TOP detector for Belle II at SuperKEKB

    … part of the Belle II detector located at the interaction point of the SuperKEKB electron-positron collider in Tsukuba, Japan.

    hawaii Repository record for Development of a readout system for the TOP detector for Belle II at SuperKEKB (opens in a new tab)

  4. An optical storage cavity-based, Compton-backscatter X-ray source using the MKV free electron laser

    … by tightly focusing the two beams at an interaction point within a near-concentric optical storage cavity, designed with high finesse to coherently stack the incident laser pulses and greatly enhance the number of photons available for scattering with the electron beam. This dissertation …

    hawaii Repository record for An optical storage cavity-based, Compton-backscatter X-ray source using the MKV free electron laser (opens in a new tab)

  5. Investigations of a conformal tracking algorithm with SiD at the ILC

    … fake rate, for isolated muons produced at the interaction point that traverse the central region of the detector. For such particles with transverse momentum greater than 30 GeV, the reconstructed track transverse momentum resolution meets the ILC physics requirements. The step in the default …

    bristol Repository record for Investigations of a conformal tracking algorithm with SiD at the ILC (opens in a new tab) Download PDF for Investigations of a conformal tracking algorithm with SiD at the ILC (opens in a new tab)

  6. Large Angle Beamstrahlung Monitor

    … beam parameters in a particle accelerator at the interaction point in order to have more control over the accelerator. The LABM collects visible radiation emitted during or just before beam collisions. The LABM has provided results so far, in the paper “A Neural Network approach to reconstructing …

    wayne-thes Repository record for Large Angle Beamstrahlung Monitor (opens in a new tab)

  7. Bayesian Nonparametric Approaches for Modelling Stochastic Temporal Events

    … with the consideration of event similarity, interaction, occurrence time and emitted observation. Specifically, I tackle following three main challenges in the modelling. 1. Data sparsity. Data sparsity problem is common in many real-world temporal event modelling applications, e.g., water …

    unsw Repository record for Bayesian Nonparametric Approaches for Modelling Stochastic Temporal Events (opens in a new tab)

  8. Inverse Compton Light Source: A Compact Design Proposal

    … beam of reasonable size to be focused at the interaction point, while preserving the low emittance that was generated by the gun. An aggressive final focusing section following the electron beam's exit from the accelerator produces the small spot size at the interaction point which results in …

    odu Repository record for Inverse Compton Light Source: A Compact Design Proposal (opens in a new tab)

  9. An intra-pulse fast feedback system for a future linear collider

    <p>An intra-pulse Interaction Point fast feedback system (IPFB) has been designed for the Next Linear Collider (NLC), to correct relative beam-beam misalignments at the Interaction Point (IP). This system will utilise the large beam-beam kick that results from the beam-beam interaction and apply a …

    oxford Repository record for An intra-pulse fast feedback system for a future linear collider (opens in a new tab)

  10. Characterization of a 6 DOF Haptic Device for Mixed-Reality Temporal Bone Surgery Simulation

    … gripper on the system and to transmit the haptic interaction point to the drill tip, where the soft tissue model’s forces should be felt. This developed system should contribute in providing a more realistic surgery simulation.

    manitoba Repository record for Characterization of a 6 DOF Haptic Device for Mixed-Reality Temporal Bone Surgery Simulation (opens in a new tab)

  11. Implementation of Machine Learning Techniques in the Search for Emerging Jets Using the ATLAS Run II Dataset

    … produce jets at various displacements from the interaction point. These jets 'emerge' into the detectors, producing a unique signature at collider experiments. Introducing a boosted decision tree into this analysis enables sensitivity to several emerging jets models which cover a wide parameter …

    carleton Repository record for Implementation of Machine Learning Techniques in the Search for Emerging Jets Using the ATLAS Run II Dataset (opens in a new tab)

  12. Conceptual design of the spin rotator for the SuperKEKB High Energy Ring

    … the longitudinal electron polarization at the interaction point (IP). In this design, four existing dipoles will be replaced with four rotator magnets on both sides of the IP. The rotator magnet structure consists of dipole-solenoid combined function magnets with skew-quadrupoles installed on …

    uvic Repository record for Conceptual design of the spin rotator for the SuperKEKB High Energy Ring (opens in a new tab)

  13. ABCD and Template Fitting for Background Estimation Using 90 Signal Models in the Search for Emerging Jets at the ATLAS Experiment at the Large Hadron Collider

    … Model via a dark mediator particle, Xd. This interaction may occur at displaced points from the original interaction point, resulting in the sudden emergence of these jets. The analysis uses Monte-Carlo simulated events at a luminosity of 139fb−1 and an energy of √s = 13TeV . This thesis shows …

    carleton Repository record for ABCD and Template Fitting for Background Estimation Using 90 Signal Models in the Search for Emerging Jets at the ATLAS Experiment at the Large Hadron Collider (opens in a new tab)

  14. A Search for Dark Photons with the FASER Detector at the LHC

    … in proton-proton collisions at the ATLAS interaction point that travel in the far-forward direction. FASER is sensitive to probing previously unconstrained dark photon models, which is a theoretical particle that could provide a portal between the standard model of particle physics and a …

    oregon Repository record for A Search for Dark Photons with the FASER Detector at the LHC (opens in a new tab)

  15. Modeling Gibbs point processes through basis function decompositions

    … REQUEST.] We consider non-homogeneous pairwise interaction point process models, where the global and local effect functions are modeled using basis function expansions. For data with interaction between points, we use an ordered exponential prior on the interaction coefficients. For data …

    missouri Repository record for Modeling Gibbs point processes through basis function decompositions (opens in a new tab)

  16. Design and Implementation of the Powered Self-Contained AMPRO Prostheses

    … walking on-line, and serves as the feedback interaction point between human and prosthesis. The end result is the experimental verification of the proposed methodology in achieving stable and robust locomotion on a powered prosthesis. Furthermore it is concluded that reducing the weight of …

    tamu Repository record for Design and Implementation of the Powered Self-Contained AMPRO Prostheses (opens in a new tab)

  17. Next Generation X-Ray Monitor for bunch-by-bunch monitoring of nanometer beam sizes at the world's highest luminosity particle collider

    … of nanometers, to improve luminosity at the interaction point, there is a need for faster sampling and an ultra-low noise detector to monitor the beam and to determine beam-beam effects. The construction of the bunch-by-bunch X-ray Monitor (XRM) began in 2011, along with a new detector called …

    hawaii Repository record for Next Generation X-Ray Monitor for bunch-by-bunch monitoring of nanometer beam sizes at the world's highest luminosity particle collider (opens in a new tab)

  18. A Self-Consistent "Realistic" Pairing Theory with Applications to Two-Nucleon Transfer Reactions

    … matrix elements of the effective nucleon-nucleon interaction in a space of one, two and three-pair excitations from a Skyrme Hartree-Fock solution for deformed rotational nuclei. The "pairing" excitation energy for the configurations of time-reversed pairs of particles is obtained from the …

    mcmaster Repository record for A Self-Consistent "Realistic" Pairing Theory with Applications to Two-Nucleon Transfer Reactions (opens in a new tab)

Page 1 of 5