Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 6 of 6 for “"interbody device"”.
-
Clinically Relevant Biomimetic Bioreactors For Electrical Stimulation of Hard and Soft Tissue Applications
… first study focuses on a specific spinal fusion interbody device research question where the second and third studies investigate the viability and migration rates for soft tissue applications. The bioreactor work stemmed from early ovine studies investigating a spinal fusion interbody device …
-
Osteoporotic spine fixation : a biomechanical investigation
… hook and sublaminar wire augmentation. Anterior interbody device subsidence is another clinical problem that leads to implant loosening. Ninety-six thoracolumbar cadaveric vertebrae were compressed to failure using various shaped indentors. The focus was primarily on the superior endplate. In …
-
In vitro comparison of a new stand-alone anterior lumbar interbody cage device with established fixation techniques
… fusion across a decompressed spinal segment, interbody spacers/cages are used with and without posterior instrumentation to provide an initial "rigid" fixation of the segment. In this study three fresh/frozen human cadaveric lumbar spines were used. Each lumbar spine was dissected into two …
-
Design and characterization of additively manufactured compliant features for spinal implants
… the degenerated disc is removed, with an interbody device inserted between two adjacent vertebral bodies to restore disc height. Eventually, bone will grow over the implant providing long-term stabilization and immobilization of the joint. Spinal fusion implants are often metallic to …
-
Compliant Structures Facilitate Less Invasive and Biomechanically Improved Lumbar Spinal Implants
… mechanical testing, and validation via in vitro device insertion were performed. The design highlights the potential of compliant mechanism devices for advancing minimally invasive lumbar fusion. A new compliant mechanism called the Interior Contact-Aided Rolling Element (I-CORE) is described and …
-
The degenerate human lumbar vertebral endplate – a mechanical, clinical and histological analysis
… clinical analysis of post-operative lumbar interbody device subsidence at 12 months has been undertaken including patients from two independent tertiary specialist spinal surgery centres in order to bridge the basic science into clinical fields. Results Degeneration significantly increases …