Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 102 for “"interface circuits"”

  1. Silicon micromachined resonant accelerometer with CMOS interface circuits

    … was kept minimum by a lownoisecapacitive sense interface. The AAC loop contained a high-order loop filter and anovel chopper stabilized rectifier to remove the 1/f noise, and to minimize the phasenoise caused by the noise aliasing. The complete resonant accelerometer operates under a3.3-V supply …

    nus Repository record for Silicon micromachined resonant accelerometer with CMOS interface circuits (opens in a new tab)

  2. MULTI-CHANNEL CDMA-LIKE CAPACITIVE SENSOR INTERFACE CIRCUITS

    … advanced sensors, low-power and low-cost sensor interface circuits and efficient wireless connections. This thesis introduces a CDMA-like period modulation multi-capacitive-sensor interface circuit, which targets at the IoT applications. The proposed architecture can simultaneously read in 16 …

    nus Repository record for MULTI-CHANNEL CDMA-LIKE CAPACITIVE SENSOR INTERFACE CIRCUITS (opens in a new tab)

  3. Front-end interface circuits for integrated sensor application

    … none or very simple signal processing circuits are used. In this work, we apply modem signal processing circuitry to the resistive-type gas sensors. We tailored the signal processing circuitry to the special nature of these SnO<sub>2</sub>, based resistive-type sensors, with the …

    hkust Repository record for Front-end interface circuits for integrated sensor application (opens in a new tab)

  4. Piezoelectric energy harvesting interface circuits for energy autonomous sensors

    … using conventional diode based rectifier circuits. Moreover, the voltage output of a PET is highly susceptible to the rapidly varying frequency of ambient vibrations, causing the voltage to drop during off-resonant conditions. Impedance matching is essential to maximize the power output …

    nanyang Repository record for Piezoelectric energy harvesting interface circuits for energy autonomous sensors (opens in a new tab)

  5. High performance CMOS capacitive interface circuits for MEMS gyroscopes

    … node biasing problem present in capacitive interfaces is solved with the implementation of a transistor operating in the subthreshold region. A generalized fully differential gyroscope model with force feedback electrodes has been developed in order to simulate the capacitive interfaces with …

    metu Repository record for High performance CMOS capacitive interface circuits for MEMS gyroscopes (opens in a new tab)

  6. Integrated Time-based Sensor Interface Circuits for Implant Applications

    … is the design of integrated time-based sensor interface circuits for implant applications, targeted towards monitoring of neurochemical and neuroelectrical signals. The thesis and related publications (I - VI) describe the investigated and implemented circuits. First, a sensor interface circuit …

    aalto Repository record for Integrated Time-based Sensor Interface Circuits for Implant Applications (opens in a new tab)

  7. Wide-temperature range CMOS interface circuits for capacitive MEMS sensors

    … ºC à 225 ºC. Il est souhaitable de placer les circuits de conditionnement des capteurs à proximité des dispositifs de détection afin d'améliorer le rapport signal sur bruit et la fiabilité du système. Par conséquent, les circuits de conditionnement des capteurs doivent également être en mesure …

    mcgill Repository record for Wide-temperature range CMOS interface circuits for capacitive MEMS sensors (opens in a new tab)

  8. The design of sensor interface circuits for electrochemical impedance spectroscopy

    … and high sensitivity. The development of EIS circuits with low power consumption, reduced complexity, and faster measurement times has been a particularly active area of research. However, the lengthy measurement times and the complexity of traditional EIS systems limit their adoption in …

    cork Repository record for The design of sensor interface circuits for electrochemical impedance spectroscopy (opens in a new tab)

  9. The Low Power Interface Circuits for Energy Constrained Sensing Applications

    … The power consumption of the analog front-end circuits in a sensor system is one of the most stringent requirements. The low-power consumption not only can be environment-friendly but also can benefit the customers economically. This thesis presents a suite of design on the low power interface …

    washington Repository record for The Low Power Interface Circuits for Energy Constrained Sensing Applications (opens in a new tab)

  10. Highly Integrated CMOS Interface Circuits for SiPM Based PET Imaging Systems

    … the backend digital electronics. The front-end interface is designed using a current amplifier with a very low input impedance. Accumulation of noise presents itself as a challenge to the row-column summation architecture. This may lead to an increased chance of false triggering as compared to a …

    washington Repository record for Highly Integrated CMOS Interface Circuits for SiPM Based PET Imaging Systems (opens in a new tab)

  11. LOW-NOISE, LOW-POWER, MINIATURIZED SENSOR INTERFACE CIRCUITS FOR WEARABLE HEALTHCARE APPLICATION

    Bio-potential sensing plays a critical role in extracting real-time ExG signals and facilitating the diagnosis and treatment of diseases such as seizure and cardiovascular abnormalities. The design of low-power and low-noise ExG sensing SoCs in a wearable form factor is essential. The proposed …

    nus Repository record for LOW-NOISE, LOW-POWER, MINIATURIZED SENSOR INTERFACE CIRCUITS FOR WEARABLE HEALTHCARE APPLICATION (opens in a new tab)

  12. Analysis and design of analog interface circuits for capacitive detector readout systems

    … have enabled implementation of ultra-low-power circuits and systems for variety of applications including readout systems for capacitive radiation detectors. As state-of-the-art readout systems may integrate thousands of electronic channels on chip, designing low-power and low-noise interface …

    ubc Repository record for Analysis and design of analog interface circuits for capacitive detector readout systems (opens in a new tab)

  13. Vibration Energy Harvesting with Piezoelectric Nonlinear Energy Sink and Nonlinear Interface Circuits

    … real applications. In the past decade, advanced interface circuits have been proven to be able to boost up efficiency in various linear and nonlinear vibration energy harvesters in terms of circuitry. Techniques of the synchronized charge extraction (SCE) and synchronized switching harvesting on …

    auckland-ms Repository record for Vibration Energy Harvesting with Piezoelectric Nonlinear Energy Sink and Nonlinear Interface Circuits (opens in a new tab)

  14. CMOS interface circuits for spin tunneling junction based magnetic random access memories

    … memories. In any memory, some kind of an interface circuit is needed to read the logic states. In this thesis four such circuits are proposed and designed for Magnetic memories (MRAM). These circuits interface to the Spin tunneling junctions and act as sense amplifiers to read their …

    iastate Repository record for CMOS interface circuits for spin tunneling junction based magnetic random access memories (opens in a new tab)

  15. Interface circuits for readout and control of a micro-hemispherical resonating gyroscope

    … presents the electronic control and read-out interface that has been developed to turn the μHSR into a fully functional micro-hemispherical resonating gyroscope (μHRG) capable of measuring the rate of rotation. First, the μHSR was characterized, which both enabled the design of the interface …

    gatech Repository record for Interface circuits for readout and control of a micro-hemispherical resonating gyroscope (opens in a new tab)

  16. Design and implementation of ultra-low-power sensor interface circuits for ECG acquisition

    … of ultra-low-power biomedical sensor interface circuits that are suitable for telemetric medical applications and in particular for wearable ECG devices. It is motivated by the increasing awareness and demand in pervasive and remote personal healthcare services due to population …

    nus Repository record for Design and implementation of ultra-low-power sensor interface circuits for ECG acquisition (opens in a new tab)

  17. Design of robust and low-power memory interface circuits for next generation applications

    … solutions such as Three-Dimensional Integrated Circuits (3-D ICs) are emerging as promising candidates. Unlike Two-Dimensional Integrated Circuits (2-D ICs), which have a flat layout, 3-D ICs stack multiple circuit layers, optimizing space usage and improving performance. One significant …

    nanyang Repository record for Design of robust and low-power memory interface circuits for next generation applications (opens in a new tab)

Page 1 of 6