Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 38 for “"interference fit"”.

  1. Laser surface texturing for novel interference fit joint fixation

    In this project, a new type of manufactured interference fit joint was examined. Interference fit joints hold components together in many industries, including the automotive, ICT, and aerospace industries. The interference fit joint consists of a pin and a hub region. As the rod is inserted into …

    dcu Download PDF for Laser surface texturing for novel interference fit joint fixation (opens in a new tab)

  2. Imaging and modelling the interference-fit in cementless implantation

    … initial stability, which is provided by press fitting generated during implantation. Poor initial stability may lead to excessive micromotion between the implant and bone, and potentially loosening leading to pain necessitating revision surgery. Excessive press-fit strains may damage bone, also …

    soton Download PDF for Imaging and modelling the interference-fit in cementless implantation (opens in a new tab)

  3. Contact stresses in interference-fit joints with application to sugar-mill roller assemblies.

    The interference-fit joint is widely used in machine design to connect two cylindrical machine elements. Its popularity comes from the simplicity of the assembly and the low cost of the production process. Even so, no study has examined the boundary non-linearities in the assembly of these joints. …

    arizona-thes Repository record for Contact stresses in interference-fit joints with application to sugar-mill roller assemblies. (opens in a new tab)

  4. Analysis and design enhancement of an interference fit in a slot/insert assembly condition

    An interference fit is a relatively low-cost and effective method to lock inserts within component slots. The inserts are primarily held in place by friction. This method induces various stresses within both the slot and the insert. Due to the broad range of applications for interference fits and …

    ubc Repository record for Analysis and design enhancement of an interference fit in a slot/insert assembly condition (opens in a new tab) Download PDF for Analysis and design enhancement of an interference fit in a slot/insert assembly condition (opens in a new tab)

  5. Parameter establishment for the design of interference fit tibial component of total knee replacement

    … in surgery time for cement curing. A novel interference fit implant is evaluated using finite-element processes to minimize micromotion. Bone anisotropy and patient geometry is incorporated into simulations using computed tomography (CT) data taken directly from patients. Design parameters, …

    missouri Repository record for Parameter establishment for the design of interference fit tibial component of total knee replacement (opens in a new tab)

  6. Fit for Stability: Assessing the Role of Interference Fit in Cementless Knee Implant Stability

    … bone ingrowth. This PhD thesis investigates how interference fit, the dimensional difference between implant and bone, affects primary stability in femoral and tibial components. Using cadaveric experiments and finite element (FE) modeling, the research evaluates micromotions, gap dynamics, and …

    radboud Repository record for Fit for Stability: Assessing the Role of Interference Fit in Cementless Knee Implant Stability (opens in a new tab) Download PDF for Fit for Stability: Assessing the Role of Interference Fit in Cementless Knee Implant Stability (opens in a new tab)

  7. On the Overstraining of Thick-Walled Cylinders Under Internal Fluid Pressure and Under Interference Fit Pressure

    … under internal fluid pressure and under interference fit pressure. Part II contains the author's experimental work on cylinders under internal fluid pressure. A review of previous experiments is also included. Thirdly. the author presents his theoretical and experimental work on ring and …

    glasgow Download PDF for On the Overstraining of Thick-Walled Cylinders Under Internal Fluid Pressure and Under Interference Fit Pressure (opens in a new tab)

  8. Finite element analysis of a cementless proximal femoral stem in relation to early stem stability and interface bone strain

    … <p>The effect of varying the degree of interference-fit on stem stability and interface strains was examined. Interference-fit was found to reduce significantly the micromotions of the stem, but with a diminishing reduction of micromotions with further increase in the degree of …

    soton Download PDF for Finite element analysis of a cementless proximal femoral stem in relation to early stem stability and interface bone strain (opens in a new tab)

  9. Fixation of the cementless oxford unicompartmental knee replacement

    … stability of the cementless OUKR relies on the interference fit. The 5-year results of a randomised controlled trial using radiostereometric analysis demonstrated that cementless components are as stable as cemented. Although sufficient in providing component stability, the interference fit …

    oxford Repository record for Fixation of the cementless oxford unicompartmental knee replacement (opens in a new tab)

  10. Finite element analysis for the insertion process of the press-fitted total hip arthroplasty

    … performed every year in the United States. Press-fitted artificial hip joints are wildly used for relatively young patients. It relies on the friction resistance to relative motion at the bone-implant interface to allow bone ingrowth and primary stability. Interference fit and friction coefficient …

    missouri Repository record for Finite element analysis for the insertion process of the press-fitted total hip arthroplasty (opens in a new tab)

  11. Risk reduction in the manufacturing of interference fits for laminated rotating cores of electrical machines

    … rotor speeds, placing more importance on the interference fit between the rotor core and its shaft. Traditional manufacturing methods for rotor cores, such as thermal fits or keying, typically fall short of the interference fit requirements of the rotor or present undesirable manufacturing …

    texas Repository record for Risk reduction in the manufacturing of interference fits for laminated rotating cores of electrical machines (opens in a new tab) Restricted access

  12. Laser processing of metallic surfaces for controlled micro-texturing and metallic bonding

    … of a novel method for designing high-end interference fit fasteners. In this work, a new surface laser treatment process was developed and implemented to enable enhanced usability and bond strength control of interference-fit connections. Stainless steel 316L cylindrical samples of 10 mm …

    dcu Download PDF for Laser processing of metallic surfaces for controlled micro-texturing and metallic bonding (opens in a new tab)

  13. Comparison of Load Carrying Capacity of Three and Four Lobed Polygonal Shaft and Hub Connection for Constant Grinding Diameter

    … a spur gear of 20° pressure angle at various fits. In absence of analytical solution, Finite element method has been used after verifying the results experimentally, theoretically, and DIN standard. From the finite element analysis, the hub was found to experience greater stress than the shaft …

    gvsu Repository record for Comparison of Load Carrying Capacity of Three and Four Lobed Polygonal Shaft and Hub Connection for Constant Grinding Diameter (opens in a new tab)

  14. Parametric Study of Ring Creep in Wind Turbine Bearings: A FEA-Based Study of Structure-Induced Ring Creep in Wind Turbine Main Shaft Bearings

    … contact pressure distributions that classical interference fit calculations cannot reliably predict. This study presents an FEA-based case study developed at SKF AECC to quantify the influence of aerodynamic load components on structure-induced ring creep in a generic multi megawatt wind …

    chalmers Repository record for Parametric Study of Ring Creep in Wind Turbine Bearings: A FEA-Based Study of Structure-Induced Ring Creep in Wind Turbine Main Shaft Bearings (opens in a new tab)

  15. Shrink fit effects on rotordynamic stability: experimental and theoretical study

    … rotordynamic instability in rotors caused by interference and shrink fit interfaces. The experimental studies show the presence of strong unstable subsynchronous vibrations in two different rotor setups with interference and shrink fit interfaces that were operated above their first critical …

    tamu Repository record for Shrink fit effects on rotordynamic stability: experimental and theoretical study (opens in a new tab)

  16. The effects of water displacing corrosion preventatives on the fatigue behaviour of mechanically fastened aluminium joints

    … these mechanisms. The effects of lamping force, interference fit, maximum axial load and WDCP on fatigue performance of the joint are included in the models. The effect of WDCP is assumed to give a reduction in friction coefficient. Three types of stress reduction factors are proposed in the …

    unsw Repository record for The effects of water displacing corrosion preventatives on the fatigue behaviour of mechanically fastened aluminium joints (opens in a new tab)

  17. Predictive quality modelling of polymer and metal parts fabricated by laser-based manufacturing processes

    … processed stainless steel 316 samples used for interference fit. Artificial Neural Network (ANN) and ANFIS were used to predict the characteristics of laser surface texturing. The models based on feedforward neural network (FFNN) were used to examine the effect of the laser process parameters …

    dcu Download PDF for Predictive quality modelling of polymer and metal parts fabricated by laser-based manufacturing processes (opens in a new tab)

  18. Wear reduction in modular taper-trunnion hip prostheses using straight cylindrical stems

    … THR, tapered stems are employed which are press-fitted by impaction into the ball-head. Any pull-out movement between the two components will relieve the pressure between the components rendering them loose and susceptible to fretting. To ameliorate this problem, this thesis proposes a new …

    unsw Repository record for Wear reduction in modular taper-trunnion hip prostheses using straight cylindrical stems (opens in a new tab)

Page 1 of 2