Punching shear behaviour of FRP-reinforced concrete interior slab-column connections
Flat slab-column connections are common elements in reinforced concrete (RC) structures such as parking garages. In cold weather regions, these structures are exposed to de-icing salts and aggressive environments. Using fiber reinforced polymer (FRP) bars instead of steel in such structures will …
-
A NEW PUNCHING SHEAR STRENGTHENING TECHNIQUE FOR REINFORCED CONCRETE SLABS AT INTERIOR SLAB-COLUMN CONNECTIONS
… Shear Bolts is a new approach to strengthening slab-column connections. Reported in this thesis are the results of research on the use of shear bolts for reinforced concrete interior slab-column connections without unbalanced moments. Six slab specimens were tested with different configurations …
-
INVESTIGATION OF PUNCHING SHEAR DESIGN APPROACHES IN TURKISH BUILDING EARTHQUAKE SPECIFICATION FOR INTERIOR SLAB-COLUMN CONNECTIONS
… critical due to possible punching failure at slab-column connections. Importance of having reliable design and guidelines on punching shear design of slab-column connections under lateral loads have been shown in the past for zones under high seismic risk. In the new Turkish Building …
-
Influence of size on punching shear strength of concrete slabs
The punching shear behaviour of interior slab-column connections in flat plates is investigated. The response of six two-way slab specimens, which were designed such that they would fail in punching shear, are presented. The parameter introduced in the experimental program is member depth. The …
-
Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slabs Supported on Rectangular Columns
… for the punching shear of reinforced concrete slabs supported on rectangular columns vary greatly and are primarily based on empirical results. Additionally, the existing database for slabs supported on rectangular columns is quite small compared to the empirical database for reinforced …
-
Evaluation of punching shear strength design and modelling approaches for slab-column connections
Flat plate systems are constructed with slabs directly supported on columns. Since there are no beams in the system, the behavior of connections between the slabs and columns play a crucial role. Due to the sudden and brittle nature of punching shear failures, slab-column connection design must be …
-
Effect of high-strength concrete on the performance of slab-column specimens
The behaviour of interior slab-column connections in flat plates is investigated. The first part of this thesis discusses six two-way slab-column specimens which were designed such that they would fail in punching shear. The parameters investigated were the use of high-strength concrete and the …
-
Behavior of two-way slabs reinforced with GFRP bars
… reinforcement for high strength concrete two-way slabs is investigated. A total of six interior slab-column connections, were cast and tested to failure at the structural laboratory of MUN. The dimensions of the simply supported tested slabs were 1900 X 1900 mm square and the thicknesses were 150 …
-
Punching Shear Retrofit of Concrete Slab-Column Connections with GFRP Shear Bolts
… changes due to material deterioration or damage. Slab-column connections in flat slab structures might need to be strengthened for punching shear. Using steel shear bolts to strengthen connections for punching shear is a new technique used for retrofit that was developed at the University of …
-
Investigating the effects of hybrid fibres on the structural behaviour of two-way slabs
… of hybrid fibres on the performance of two-way slabs. The hybrid fibres were a cocktail of steel and macrosynthetic fibres. An experimental investigation was carried out to examine the structural behaviour of hybrid-fibre-reinforced concrete (HFRC) two-way slabs under static loading conditions. …
-
Concrete slabs reinforced with GFRP bars
… of flat plates is investigated. In total, nine interior slab-column connections, that represent full scale specimens, were made and tested to failure at the structural laboratory of MUN. The 1900 x 1900 mm square slabs were simply supported along the four edges. The reinforcement ratio, concrete …
-
Seismic behaviour of slab-column connections without transverse reinforcement
Reinforced concrete (RC) flat slabs supported by slender columns are often used as gravity load resisting system for buildings in regions of moderate and high seismicity. Such buildings are typically braced by RC walls, which carry the largest portion of the horizontal loads generated during …
-
Rehabilitation of reinforced concrete slab-column connections for two-way shear
… system, it is prone to brittle shear failure at slab-column connections, which may result in the progressive collapse of a building. For that reason, connections with insufficient two-way shear strength may need to be rehabilitated and rehabilitation can be a cost-effective alternative to …
-
Punching strength of continuous flat slabs
Reinforced concrete slabs with uniform thickness are common in residential and commercial buildings but can also be found in other types of structures. Such slabs are susceptible to punching shear failures, where a supporting column penetrates through the slab and leads to an immediate local …
-
Influence of bond and anchorage conditions of the shear reinforcement on the punching strength of RC slabs
Reinforced concrete flat slabs constitute one of the most common and efficient modern construction methods. The design of such structural system might be governed by a brittle failure in the vicinity of the slab-column connection associated to punching shear. The arrangement of transverse …