Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 384 for “"internal standard"”.
-
Expression of recombinant human metallothionein 2A as internal standard for mass spectrometric analysis of metallothioneins
… a mass spectrometry-based method, a MT (MT-2A) standard similar to the native form but with a slightly different mass was required. Due to the lack of pure human MT standards and high cost of pure rabbit MT standards, it was decided to create a recombinant human MT-2A with different mass due to …
-
Effect of Internal Standard Normalization of Microbiome Data on Outcomes of a Controlled Feeding Study and a Longitudinal Study in a Multiethnic Cohort
Standardization would benefit the interpretability of human microbiome data because unintended variability can be introduced at each level of data production and processing. One way to bring standardization to microbiome studies is with internal standards (IS). In three microbiome sequencing …
-
A PROPOSED NEW INTERNAL STANDARD FOR FREE, GLYCOSYLATED AND TOTAL PYRIDINIUM CROSSLINKS QUANTIFICATION IN HEALTHY WOMEN AND CHILDREN URINE: VALIDATION OF AN HPLC-FLUORESCENCE METHOD
… are often compromised by the lack of an adequate internal standard allowing to eliminate errors occurring during sample preparation and analytical measurement. In spite of extensive literature, important points for crosslinks measurement have not been solved: 1) the choice of an adequate internal …
-
Comparison Of Two Methods For Differentiating Negative From Inconclusive GC-MS Test Results Using An Isotopic Analog Of The Analyte As The Internal Standard - 11-Nor-Δ9- Tetrahydrocannabinol-9-Carboxylic Acid Example
… spectrometry (GC-MS), a drop in internal standard response is an indicator of possible sample adulteration. In 2007, Dennis V. Canfield (Liu et al. 2007) developed a formula to calculate factor A, an empirically determined value for the lowest acceptable internal standard (IS) …
-
Improving figures of merit and expanding applications for inductively coupled plasma mass spectrometry
… routinely used to compensate for these issues. Internal standardization is one such solution that requires relatively simple sample preparation and yet offers the possibility of improving both accuracy and precision. In order to be effective, an optimal analyte/internal standard pair must be …
-
Comparative Toxicity Responses in Earthworms Lumbricus Terrestris and Eisenia Foetida to Cadmium Nitrate and Chlordane Using Artificial Soil and Filter Paper Exposures
… reference toxicant 2-chloroacetamide using the standardized 48-h FP exposure was used to assess the general response of the earthworm prior to toxicity experiments. A glucose test was developed as an internal standard to assess homogeneity of mixtures among both replicates and dilutions. …
-
Geochemical Analysis By Inductively-Coupled Plasma Optical Emission Spectroscopy Using Slurry Atomization
… particles the use of-silicon in the kaolin as an internal standard corrected for variable atomization efficiency. The addition of dispersants greatly increased slurry atomization by decreasing flocculation. Aqueous ammonia (0.35% m/v) was optimal. For high concentration slurries (>8% w/v) …
-
Analysis of avenanthramides in oats with Ultra High Performance Liquid Chromatography
… were tested, as well as the introduction of an internal standard to improve quantification. We found that the internal standard selected was not stable during extraction and that it was necessary to use an external standard curve. We found that the liquid chromatography method was reproducible …
-
A Test of an Alternate Calibration Matrix for NIOSH Method 7300
… is calibrated using EPA Method 200.7 acid matrix standards. The null hypothesis was that no statistically significant difference, measured at the 95% confidence level, would exist between results obtained from the two calibration standards. Careful standard and sample preparation, the use of an …
-
Quantitative Determination of Acetylsalicyclic Acid and Acetaminophen by Q-NMR (Quantitative Nuclear Magnetic Resonance) Technique
… of compounds but to develop a method an internal standard of known concentration is required. We are using q-NMR (quantitative NMR) to quantitatively analyze acetylsalicylic acid and acetaminophen by Proton-NMR using diethyl ether as an internal standard. The area of NMR signals shows a …
-
The Quantitative Determination of Glass in Slag and Fly Ash by Infrared Spectroscopy
… ash. Infrared absorption spectroscopy using an internal standard proved to be the method of choice. Both synthetic and commercial slags and fly ashes were investigated.
-
Application of Liquid Chromatography - Tandem Mass Spectrometry Techniques to Forensic, Environmental and Clinical Analyses.
… observation found that where suppression of internal standard signals resulted in reproducibility outside of standard limits (>20% RSD), if the signal was stable and within the linear range, the ratio of the analyte and internal standard signals was consistent and proportional to the …
-
Characterisation of the Microbial Community in Indoor Environments: a Chemical-Analytical Approach
… 13C-labelled cyanobacterial cells was used as an internal standard for the first three markers (13C-labelled 3-hydroxytridecanoic acid from labelled Pectinatus cerevisiiphilus was used as an alternative internal standard to improve quantification of the 3-hydroxy fatty acids) and …
-
Quantitative Spark-Source Mass Spectrometric Techniques for the Simultaneous Determination of the Lanthanide and Actinide Elements in Microgram and Sub-Microgram Transuranium Samples
… were established with respect to erbium, the internal standard, for rare earth elements and for thorium, uranium, neptunium, americium, curium, berkelium, and californium.</p> <p>A special glove box was designed, fabricated, and used on the source end of the mass spectrometer so that samples …
-
The use of trace elements in correlating Rhyolitic lava flows
… elements were analyzed quantitatively using the internal standard method in conjunction with a 2.0:1 step-sector disc. Copper 3247.5 was chosen as the most suitable internal standard line because of its proximity to the other lines examined in this investigation. The emulsion was calibrated and …
-
Analysis of Propylene Glycol in Human Saliva Samples Using Gas Chromatography-Mass Spectrometry
… saliva. The sample will be combined with the internal standard (PG-d8) and undergo heptafluorobutyric anhydride derivatization of the internal standard spiked sample to produce di-heptafluorobutyrate esters of PG and PG-d6. This is followed by a liquid-liquid extraction step to eliminate the …
-
Issues in Laser Induced Breakdown Spectroscopy for Measurements in the Deep Ocean and Other High-Pressure Environments
… into the use of hydrogen and oxygen as an internal standard for lithium and potassium in bulk aqueous solution. These investigations reveal that the precision in the measured LIBS signal for Li and K is improved by using H or O as an internal standard, with oxygen providing up to a 9-fold …
-
Shiga Toxin-Producing Escherichia coli (STEC) Detection Strategies with Formalin-Fixed STEC Cells
… set of known cell concentration samples and internal standard i.e. positive control. These cell concentrations may be used across laboratories in different geographical locations, within an individual laboratory, and across a broad range of detection assays (molecular as well as …
-
Method Transfer for Gas-Chromatography Ion Mobility Spectrometry from Laboratory to Industrial Instrumentation
… events during manufacturing. The current gold standard method of microbial culturing, such as the dip-slide method, of analysing such events have a feedback time of around 48 hours which is not compatible with modern manufacturing processes. The need for a more efficient detection system is …
-
Thin layer chromatography-matrix assisted laser desorption ionisation-mass spectrometry of pharmaceutical compounds.
… nature of the silica gel layer was corrected by internal recalibration on selected matrix ions during the scanning of the TLC plate. To enhance the signals recorded directly from a TLC plate the use of an extraction solvent prior the matrix application was explored. Further improvements in …
Page 1 of 20