  1. A study of the uses of scattered x-rays for internal standardization in x-ray spectroscopic analysis

    The use of scattered x-rays as an internal standard is evaluated in detail. The physical bases of secondary emission and scattering are described using the isolated atom model of photon-matter interactions. Unique quantitative expressions relating analyte concentration, intensity of analyte …

    hawaii Repository record for A study of the uses of scattered x-rays for internal standardization in x-ray spectroscopic analysis (opens in a new tab)

  2. Optimization of the analytical performance of an inductively coupled plasma mass spectrometer

    … The role of ultrasonic nebulization and internal standardization is;evaluated. Applications to uranium analysis, stable isotope tracing, flow injection analysis and liquid chromatographic detection are given; ('1)USDOE Report IS-T 1214. This work was performed under Contract W-7405-eng-82 …

    iastate Repository record for Optimization of the analytical performance of an inductively coupled plasma mass spectrometer (opens in a new tab)

  3. Selenium Determination using Oxygen Mass-Shift Interference Removal Technology with LC-ICP-MS/MS

    … many advantages, previous methodologies, such as internal standardization, need to be updated.In this work, method development of sample preparation and instrumental considerations were completed using oxygen mass-shift interference removal technology for the ICP-QQQ. An evaluation of internal …

    ohiolink Repository record for Selenium Determination using Oxygen Mass-Shift Interference Removal Technology with LC-ICP-MS/MS (opens in a new tab)

  4. Determination of formaldehyde by ion exclusion and ion exchange separation with amperometric detection

    … applied potentials for the best detection. An internal standardization was used to correct for detector drift. An interference study was performed for organic acids, other aldehydes, and alcohols. Using impingers containing aqueous bisulfite solution for collection, a side by side comparison …

    unlv Repository record for Determination of formaldehyde by ion exclusion and ion exchange separation with amperometric detection (opens in a new tab)

  5. Seleção de padrões internos para análise elementar em métodos instrumentais com plasma induzido

    … the challenges and strategies to use the internal standardization calibration method in two instrumental methods, i.e. inductively coupled plasma optical emission spectrometry (ICP-OES) and microwave induced plasma optical emission spectrometry (MIP-OES), for complex matrix analysis. In …

    brazil-ufscar Repository record for Seleção de padrões internos para análise elementar em métodos instrumentais com plasma induzido (opens in a new tab)

  6. "Integral methodology for designing and implementing a TQM system within companies"

    … is being held by four subsystems such as: internal standardization, methods and techniques for flawless work performance, education and motivation and analyses of the quality costs. The existing condition was being analyzed through the set criteria for receiving a European Quality Award: …

    delcev Repository record for "Integral methodology for designing and implementing a TQM system within companies" (opens in a new tab)

  7. Análise elementar de carnes: desenvolvimento de métodos analíticos e estratégias para técnicas com fonte de plasma

    … module (EGCM) and the signal correction applying internal standardization (Te) and molecular species (OH). The accuracy was estimated by comparing the results obtained with ion chromatography. The recovery found using the internal standardization was 95%, while molecular specie was 94%. These …

    brazil-ufscar Repository record for Análise elementar de carnes: desenvolvimento de métodos analíticos e estratégias para técnicas com fonte de plasma (opens in a new tab)

  8. A zero-bias spark source for direct solid sample introduction for inductively coupled plasma atomic emission spectrometry

    … constituents in the samples were achieved. No internal standardization was required due to the similarity of the sample matrices for each series of samples. Experiments to measure spark reproducibility were performed. Acceptable accuracy and precision were achieved.

    wayne-thes Repository record for A zero-bias spark source for direct solid sample introduction for inductively coupled plasma atomic emission spectrometry (opens in a new tab)

  9. Calibration strategies for elemental determination using direct solid analysis by x-ray spectroscopy and laser-induced breakdown spectroscopy

    … strategies were matrix-matching calibration, internal standardization, calibration-free, single-sample calibration, one-point and multi-line calibration, two-point calibration transfer, partial least squares regression and linear combination fitting. Two new univariate calibration strategies …

    brazil-ufscar Repository record for Calibration strategies for elemental determination using direct solid analysis by x-ray spectroscopy and laser-induced breakdown spectroscopy (opens in a new tab)

  10. Determinação de impurezas inorgânicas em medicamentos: avaliação de preparo de amostra e medidas espectroanalíticas

    … strategies, such as standard additions, internal standardization, multi-isotope calibration and one-point standard addition, are evaluated for correction of matrix effects as well as instrumental strategies based on aerosol dilution and collision cell technology for ICP-MS measurements. …

    brazil-ufscar Repository record for Determinação de impurezas inorgânicas em medicamentos: avaliação de preparo de amostra e medidas espectroanalíticas (opens in a new tab)

  11. Determination of polycyclic aromatic hydrocarbons in the water, soils and surface sediments of the Msunduzi River, KwaZulu-Natal, South Africa.

    … by GC-MS. The instrument was calibrated using internal standardization (deuterated PAH) and PAH standards. Percentage recoveries of 7 PAHs in the spiked and equilibrated samples varied from 79.16±0.01 to 101.28±0.02 and 80.30±0.02 to 105.56±0.01 for solid and water samples, respectively. The …

    ukzn Repository record for Determination of polycyclic aromatic hydrocarbons in the water, soils and surface sediments of the Msunduzi River, KwaZulu-Natal, South Africa. (opens in a new tab)

  12. AUTOMATION OF CALIBRATION METHODS APPLIED TO INDUCTIVELY COUPLE PLASMA OPTICAL EMISSION SPECTROMETRY

    … such as external standard calibration (EC), internal standardization (IS), and standard additions (SA), are widely utilized in quantitative analyses. Many samples present several concomitant species that can cause matrix effects, which can compromise the accuracy of an analytical method when …

    wfu Repository record for AUTOMATION OF CALIBRATION METHODS APPLIED TO INDUCTIVELY COUPLE PLASMA OPTICAL EMISSION SPECTROMETRY (opens in a new tab)

  13. Improving figures of merit and expanding applications for inductively coupled plasma mass spectrometry

    … routinely used to compensate for these issues. Internal standardization is one such solution that requires relatively simple sample preparation and yet offers the possibility of improving both accuracy and precision. In order to be effective, an optimal analyte/internal standard pair must be …

    texas Repository record for Improving figures of merit and expanding applications for inductively coupled plasma mass spectrometry (opens in a new tab)

  14. Language history as a history of diversity : a study of language history from below of Early New High German

    … overlaps with the presumed end phase of an internal standardization process of the German written language, which is also the focus of this dissertation in order to make a direct comparison possible. Six orthographic features that are well-documented and should show a strong tendency towards …

    texas Repository record for Language history as a history of diversity : a study of language history from below of Early New High German (opens in a new tab)

  15. Expanding the Capabilities of Inductively Coupled Plasma Optical Emission Spectrometry and Mass Spectrometry: Optimization of Plasma and Sample Introduction Conditions

    … ICP OES, without using any matrix matching or internal standardization. 2. An IR-heated sample introduction system with a conventional pneumatic nebulizer was investigated in order to improve the analytical performance of ICP OES. The aerosol generated by a pneumatic nebulizer, coupled to …

    queens Repository record for Expanding the Capabilities of Inductively Coupled Plasma Optical Emission Spectrometry and Mass Spectrometry: Optimization of Plasma and Sample Introduction Conditions (opens in a new tab)

  16. Solid Sampling Electrothermal Vapourization Coupled to Inductively Coupled Plasma Optical Emission Spectrometry for Geochemical Exploration

    … 0–4 mg of soil reference material, together with internal standardization with an argon emission line, yielded results for Zn and P in good agreement with those obtained, following aqua regia (AR) digestion, by ICP mass spectrometry (MS). The vertical distribution of target elements in soil …

    queens Repository record for Solid Sampling Electrothermal Vapourization Coupled to Inductively Coupled Plasma Optical Emission Spectrometry for Geochemical Exploration (opens in a new tab)

  17. The investigation of high performance techniques and application to complex matrices using inductively coupled plasma spectrometry and the impact of urbanization on the Scioto River system

    Simultaneous, time-correlated internal standardization and drift correction can provide concentration uncertainties on the order of 0.1% (typically 5 - 10%) in inductively coupled plasma optical emission spectrometry (ICP-OES). All measurement error resulting from the instrument can essentially be …

    ohiolink Repository record for The investigation of high performance techniques and application to complex matrices using inductively coupled plasma spectrometry and the impact of urbanization on the Scioto River system (opens in a new tab)

  18. Investigação de processos colisionais e reacionais para cromo e vanádio em interface de espectrômetro de massa com plasma indutivamente acoplado

    … combustion (MIC) and sample dilution with internal standardization for different samples were investigated. It was observed that the collision and reaction devices employed led to improvements of SBR, BEC and LOD values for Cr and V from 5 to 100-fold when compared with measurements without …

    brazil-ufscar Repository record for Investigação de processos colisionais e reacionais para cromo e vanádio em interface de espectrômetro de massa com plasma indutivamente acoplado (opens in a new tab)

  19. Fundamental Capillary Electrophoresis: An Evaluation of Electrokinetic Sampling

    … injection. When quantitation methods such as internal standardization or internal area normalization are used, preinjection rinsing conditions are irrelevant. With a better understanding of analyte mobility, the field of capillary electrophoresis analysis may be extended to the analysis of …

    shu-thes Repository record for Fundamental Capillary Electrophoresis: An Evaluation of Electrokinetic Sampling (opens in a new tab)