Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 190 for “"internal standards"”.

  1. Method Development and Validation of the Quantitation of 19 Antipsychotics Using Deuterated Internal Standards

    … approximately 19 antipsychotics with deuterated internal standard in postmortem human blood. Compound optimization parameters for detecting a specific compound as well as a quantitative assay of the antipsychotic compounds were accomplished. Validation parameters such as determination of …

    buff-state Repository record for Method Development and Validation of the Quantitation of 19 Antipsychotics Using Deuterated Internal Standards (opens in a new tab)

  2. Synthesis of Fc peptides and glycopeptides to be used as internal standards for absolute quantitation of glycoforms of two human IgG subclasses by MALDI-MS analysis

    … using a solid phase approach and used as internal standards for enriched fractions from human IgG tryptic digests. Mass spectrometry was used to analyze biomolecules quantitatively throughout the experiment. Tryptic digest glycopeptides from monoclonal IgG1 and IgG2 samples were first …

    manitoba Repository record for Synthesis of Fc peptides and glycopeptides to be used as internal standards for absolute quantitation of glycoforms of two human IgG subclasses by MALDI-MS analysis (opens in a new tab)

  3. Synthesis of isotope-labelled methoxypyrazine compounds as internal standards and quantitative determination of aroma methoxypyrazines in water and wines by solid-phase extraction with isotope dilution-GC-MS /

    An efficient way of synthesizing the deuterium labelled analogues of three methoxypyrazine compounds: 2-d3-methoxy-3-isopropylpyrazine, 2-d3-methoxy-3- isobutylpyrazine, and 2-d3-methoxy-3-secbutylpyrazine, has been developed. To confirm that the deuterium labels had been incorporated into the …

    brock Repository record for Synthesis of isotope-labelled methoxypyrazine compounds as internal standards and quantitative determination of aroma methoxypyrazines in water and wines by solid-phase extraction with isotope dilution-GC-MS / (opens in a new tab)

  4. Chemical synthesis of isotopically labelled (M+4) purine nucleosides and their incorporation into DNA oligomers

    … on the use of multiply, isotopically-labelled internal standards. This project is aimed at making available such internal standards. The first task was to synthesise the multiply, isotopically-labelled bases (M+4) guanine and (M+4) 8-oxo-guanine. Synthetic routes for both (M+4) guanine and …

    aston Download PDF for Chemical synthesis of isotopically labelled (M+4) purine nucleosides and their incorporation into DNA oligomers (opens in a new tab)

  5. The effects of power on its users

    … make the decision, the power user considers both internal standards and experiences (either vicariously gained or directly). Having acted, the power user then evaluates his or her action against both feedback and internal standards. If evaluation indicates that the action was contrary to either …

    unsw Repository record for The effects of power on its users (opens in a new tab)

  6. Effect of Internal Standard Normalization of Microbiome Data on Outcomes of a Controlled Feeding Study and a Longitudinal Study in a Multiethnic Cohort

    … standardization to microbiome studies is with internal standards (IS). In three microbiome sequencing methods—16S rRNA gene sequencing, and metagenomic and metatranscriptomic sequencing—this standardization can involve the addition of nucleic acid sequences into a sample. We assessed how …

    washington Repository record for Effect of Internal Standard Normalization of Microbiome Data on Outcomes of a Controlled Feeding Study and a Longitudinal Study in a Multiethnic Cohort (opens in a new tab)

  7. Investigation of Ionic-Liquid-Based Dispersive Liquid-Liquid Microextraction and Lipid Adduct Formation for Untargeted Lipidomics

    … unsuitable for untargeted lipidomics of plasma. Internal standards are commonly used for semi-quantification in untargeted lipidomics. However, electrospray ionization (ESI) differences between internal standards and endogenous lipids can impact quantification accuracy. The adduct formation for …

    concordia Download PDF for Investigation of Ionic-Liquid-Based Dispersive Liquid-Liquid Microextraction and Lipid Adduct Formation for Untargeted Lipidomics (opens in a new tab)

  8. Acting Ethically: Behavior and the Sustainable Society

    … personal efficacy, social influence, and internal standards. Because these three factors play a prominent role in behavior, it is necessary to examine what role they play in creating sustainability and how they may be utilized to achieve optimal behavior patterns. Ultimately, in order to …

    unt Repository record for Acting Ethically: Behavior and the Sustainable Society (opens in a new tab)

  9. Detection and quantitation of diazinon and chlorpyrifos : a novel GC

    … be impractical to use isotope-labeled analogs as internal standards for all analytes in a complicated matrix. Compounds may have to be used as internal standards which could cause non-linear effects because of different response of analytes and internal standards. A novel sample introduction …

    u-pacific Repository record for Detection and quantitation of diazinon and chlorpyrifos : a novel GC (opens in a new tab)

  10. In situ sintering study of model nickel catalysts

    … pathways. The development of biomarkers and internal standards to perform quantitative and qualitative analysis of metabolites in the catabolic pathway would be an attractive tool. Thus, cholesterol derivatives were synthesized as thia-, fluoro- and deuterium labeled analogs. Sulfur was …

    cape-town Repository record for In situ sintering study of model nickel catalysts (opens in a new tab)

  11. Perchlorate and iodide in biological samples

    … nutrition. We explored the use of different internal standards for measuring iodine in milk and urine samples by MS. It was found that certain internal standards worked for certain samples but using 129I universally performed as the best internal standard for iodine analysis.

    ttu Repository record for Perchlorate and iodide in biological samples (opens in a new tab)

  12. TOOLS FOR THE IMPROVEMENT OF FLAVOR IN INTERSPECIFIC HYBRID GRAPE VARIETIES: A POST HOC ANALYSIS METHOD FOR QUANTITATION OF VOLATILES AND A PROFILE OF MALATE DURING BERRY MATURATION ACROSS VITIS SPP.

    … two populations were spiked with a cocktail of internal standards (n = 6, 9, respectively) prior to HS-SPME-GC-MS. Variation in the relative responses of internal standards indicated that Compound × Individual interactions exist, but were different between the two populations. For the grape …

    cornell Repository record for TOOLS FOR THE IMPROVEMENT OF FLAVOR IN INTERSPECIFIC HYBRID GRAPE VARIETIES: A POST HOC ANALYSIS METHOD FOR QUANTITATION OF VOLATILES AND A PROFILE OF MALATE DURING BERRY MATURATION ACROSS VITIS SPP. (opens in a new tab)

  13. Interlaboratory Comparison of a Complex Targeted Assay: Improving Consistency and Reliability in Metabolomics Analyses

    Ideal isotope-labeled internal standards for analysis via targeted metabolomics approaches are presented for negative and positive ion modes for both hydrophilic interaction liquid chromatography (HILIC) and reverse phase liquid chromatography (RPLC) chromatography coupled to mass spectrometry. …

    gatech Repository record for Interlaboratory Comparison of a Complex Targeted Assay: Improving Consistency and Reliability in Metabolomics Analyses (opens in a new tab)

  14. A multi-mode spectrometer for atomic emission spectrometry

    … capabilities in data compression, application of internal standards, and noise spectrum analysis.

    vt Repository record for A multi-mode spectrometer for atomic emission spectrometry (opens in a new tab)

  15. Quantitative matrix isolation Fourier transform spectroscopy of polycylic aromatic hydrocarbons

    … the increase in precision gained from the use of internal standards. Two PAH's, pyrene and triphenylene, were identified as suitable internal standards.</p><p>MI FTIR was utilized in the qualitative and quantitative determination of the PAH content of "real samples." Four components of a synthetic …

    utk-theses Repository record for Quantitative matrix isolation Fourier transform spectroscopy of polycylic aromatic hydrocarbons (opens in a new tab)

  16. Evaluation and development of precise methods for glycan analysis using mass spectrometry

    … to producing stable isotope-labelled glycan internal standards was devised and evaluated, which has been dubbed D3-tagging, with D3 referring to three deuteria atoms present on N-acetylated carbohydrates. The D3-tagged internal standards were found to improve the precision of glycomics data, …

    ubc Repository record for Evaluation and development of precise methods for glycan analysis using mass spectrometry (opens in a new tab) Download PDF for Evaluation and development of precise methods for glycan analysis using mass spectrometry (opens in a new tab)

  17. Dye laser excited fluorescence spectroscopy of matrix isolated polycyclic aromatic hydrocarbons

    … linear over at least two orders of magnitude. An internal standard was not needed. Expressed in terms of relative standard deviation, the precision of matrix isolation site selection fluorometric analysis was on the order of 8%. Detection limits for benzo(a)pyrene (BaP) and …

    utk-theses Repository record for Dye laser excited fluorescence spectroscopy of matrix isolated polycyclic aromatic hydrocarbons (opens in a new tab)

  18. Metabolism and pharmacokinetic studies of valproic acid using stable isotope techniques

    … The use of stable isotope labelled analogs as internal standards can minimize the variance arising from extraction of VPA metabolites due to a slight pH change or incompleteness of derivatization due to time and temperature. In order to obtain optimal analytical results, eight deuterium …

    ubc Repository record for Metabolism and pharmacokinetic studies of valproic acid using stable isotope techniques (opens in a new tab) Download PDF for Metabolism and pharmacokinetic studies of valproic acid using stable isotope techniques (opens in a new tab)

  19. A resonance electronic raman effect

    … cm^-1 and 266.8 cm^-1, the latter being used as internal standards. Intensity ratios were thus calculated and interpreted on the basis of a modified version of Placzek's polarizability model.These measurements showed a resonance enhancement of the electronic Raman transition as the incident …

    carleton Repository record for A resonance electronic raman effect (opens in a new tab)

  20. Creating a custom calibration for the portable X-ray fluorescence instrument to identify iron formation using seawater signatures

    … them from detrital contamination using internal and custom calibrations. If the pXRF could detect REE+Y concentrations, then detecting seawater signature trends locked in iron formation could be plausible in the field. Additionally, if the pXRF could measure REE+Y seawater signatures in …

    umn Repository record for Creating a custom calibration for the portable X-ray fluorescence instrument to identify iron formation using seawater signatures (opens in a new tab)

Page 1 of 10