Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 38 for “"interobserver reliability"”.

  1. Interobserver Reliability in the Diagnosis of Pulpal and Periradicular Disease

    The purpose of this study was evaluate the interobserver reliability of endodontists in the diagnosis the presence or absence of pulpal and/or periradicular disease. The study used 47 patients presenting to the VCU School of Dentistry for screening appointments as a test population under the rules …

    vcu Repository record for Interobserver Reliability in the Diagnosis of Pulpal and Periradicular Disease (opens in a new tab)

  2. Assessing five common measures of interobserver reliability, proposing new refined measures

    … on an ordinal scale. Five common measures of interobserver reliability are the overall proportion of agreement, Cohen's kappa, weighted kappa, the disagreement rate and the concordance between raters. A number of studies have assessed interobserver reliability including ones which have …

    manitoba Repository record for Assessing five common measures of interobserver reliability, proposing new refined measures (opens in a new tab)

  3. Observer Reliability of Cephalometric Landmark Identification on 3-D MR Images

    … employing MR images for cephalometric analysis, reliability of landmark identification must be assessed. The purpose of this study was to evaluate intra- and interobserver reliability in 3-dimensional landmark identification using MR images. Materials and Methods: Fifteen cranial MR images (3.0 …

    loma-linda Repository record for Observer Reliability of Cephalometric Landmark Identification on 3-D MR Images (opens in a new tab)

  4. Reliability and Validity of an Assessment of Engagement in Nursing Home Residents during Bingocize®

    … the Fun and Social Engagement Evaluation (FUSE). Reliability and validity of the FUSE were also investigated. The FUSE was administered to 57 nursing home residents across four Bingocize® sessions in each of four CNF locations. Two of the Bingocize sessions involved nursing home staff and …

    wku-diss Repository record for Reliability and Validity of an Assessment of Engagement in Nursing Home Residents during Bingocize® (opens in a new tab)

  5. The diagnosis, assessment and outcomes of primary systemic vasculitis

    … scans.’ At the superficial temporal artery, the interobserver reliability in acquired and dynamic images has a k = 0.87 and 0.60 respectively; the intraobserver reliability in acquired images and live exercises has a k = 0.88 and 0.71 respectively. Ultrasonography is more reliable (k = 0.8) than …

    east-anglia Download PDF for The diagnosis, assessment and outcomes of primary systemic vasculitis (opens in a new tab)

  6. The Effectiveness of Institutionalization of a Curricular Change in Department of Defense Dependents' Schools

    … to become established practice. To establish interobserver reliability, two observers rated teachers using the same protocol. The interobserver reliability coefficient found was reported at .9820. The participants in the study completed the Stages of Concern Questionnaire, the Administrative …

    unt Repository record for The Effectiveness of Institutionalization of a Curricular Change in Department of Defense Dependents' Schools (opens in a new tab)

  7. Transvaginal ultrasound of the uterosacral ligaments for the diagnosis of deep endometriosis

    … approach. Through a systematic review, interobserver reliability testing, and observational analysis of pain descriptors, the research found that both experienced and less experienced imaging professionals could reliably identify signs of disease using clear ultrasound criteria. …

    adelaide Repository record for Transvaginal ultrasound of the uterosacral ligaments for the diagnosis of deep endometriosis (opens in a new tab)

  8. Improving efficiency in stroke trials: an exploration of methods to improve the use of the modified Rankin Scale in acute stroke trials

    … a clinician’s rating of a patient interview and interobserver variability is common. Meta-analysis suggests an overall reliability of k=0.46 but this may be less (k=0.25) in multi-centre studies. Mandatory training in mRS assessment is employed in most trials to mitigate this but the problem …

    glasgow Download PDF for Improving efficiency in stroke trials: an exploration of methods to improve the use of the modified Rankin Scale in acute stroke trials (opens in a new tab)

  9. Testing the reliability of a newly developed sedation scale

    … levels). In addition the tool was tested for reliability. To ensure the tool was reliable, the tool underwent interobserver reliability testing. An assessment tool composed of 9 goal based parameters was developed. A pilot study was conducted in 10 AICU patients to ensure that no gross problem …

    manitoba Repository record for Testing the reliability of a newly developed sedation scale (opens in a new tab)

  10. Humeral Torsion and Shoulder Biomechanics: Comparison of a novel ultrasonographic technique with the computed tomography benchmark

    … of this thesis is to evaluate the validity, reliability, and precision of the novel ultrasound technique compared to CT in the assessment of humeral torsion, evaluating. This thesis first developed a standard CT measurement protocol that implements a quantitative method for selecting optimal …

    clemson Repository record for Humeral Torsion and Shoulder Biomechanics: Comparison of a novel ultrasonographic technique with the computed tomography benchmark (opens in a new tab)

  11. Confiabilidade interobservador da escala do equilíbrio de Berg entre fisioterapeutas com extensa e escassa prática clínica

    This study aimed at assessing the interobserver reliability of the Brazilian-Portuguese version of the Berg Balance Scale (BBS). The assessment was made by physiotherapists with extensive or little clinical experience in non-institutionalized elderly individuals. Participants comprised 12 elderly …

    brazil-ufrn Repository record for Confiabilidade interobservador da escala do equilíbrio de Berg entre fisioterapeutas com extensa e escassa prática clínica (opens in a new tab)

  12. Desenvolvimento e validação clínica de um software para medição automatizada da densidade mamária

    … 95% of 13.5 percentage points; in assessing interobserver reliability, with two radiologists with different experience, the CCI was 0.94; in assessing intraobserver reliability, the ICC was 0.98. The distribution between density classes is close to the values obtained with volumetric …

    brazil-ufrn Repository record for Desenvolvimento e validação clínica de um software para medição automatizada da densidade mamária (opens in a new tab)

  13. Tonometry and biomechanics of the cornea in contact lens wear

    … valuable chair time.Inter- and intraobserver reliability of rebound tonometer (RBT) and intraobserver reliability of ocular response analyser (ORA) with and without contact lenses of 50 (15 male, 35 female) healthy well adapted contact lens wearers between 18 – 55 years (M = 38.90, SD = 9.23) …

    aston Download PDF for Tonometry and biomechanics of the cornea in contact lens wear (opens in a new tab)

  14. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … or equal to 4 indicated "confident detection." Interobserver reliability was assessed with Krippendorff's a and quadratic-weighted k. Logistic regression modeled detection probability versus diameter, with thresholds derived for 80% (D80) and 90% (D90) detection. Descriptive bin analysis and ROC …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

  15. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … or equal to 4 indicated "confident detection." Interobserver reliability was assessed with Krippendorff's a and quadratic-weighted k. Logistic regression modeled detection probability versus diameter, with thresholds derived for 80% (D80) and 90% (D90) detection. Descriptive bin analysis and ROC …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

  16. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … or equal to 4 indicated "confident detection." Interobserver reliability was assessed with Krippendorff's a and quadratic-weighted k. Logistic regression modeled detection probability versus diameter, with thresholds derived for 80% (D80) and 90% (D90) detection. Descriptive bin analysis and ROC …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

  17. Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study

    … or equal to 4 indicated "confident detection." Interobserver reliability was assessed with Krippendorff's a and quadratic-weighted k. Logistic regression modeled detection probability versus diameter, with thresholds derived for 80% (D80) and 90% (D90) detection. Descriptive bin analysis and ROC …

    tamu Repository record for Detection Thresholds for Root Canal Visibility on High-Resolution CBCT: A Micro-CT Validation Study (opens in a new tab) Embargoed until 2027-12-01

Page 1 of 2