Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 42 for “"interstorey drift"”

  1. Interstorey Drift Performance of Timber Beam-Hanger Connections

    … loading protocol to allow for the application of interstorey drifts, and the details of the two specific beam-hanger connections tested for this research (“dove tail” and “bolted plate”). The structural design of a testing frame is then described and the final product of a steel wide flange …

    queens Repository record for Interstorey Drift Performance of Timber Beam-Hanger Connections (opens in a new tab)

  2. Investigation of seismic isolation efficiency for building structures

    … employed for efficacy assessment will be the interstorey drift ratio and floor acceleration since both structural and non-structural damage to be occured in a system are directly related to these two parameters. To assess the variations in interstorey drift ratio and floor accelerations between …

    metu Repository record for Investigation of seismic isolation efficiency for building structures (opens in a new tab)

  3. Cyclic Testing of Pre-engineered Beam-Hanger Connections & Reinforcement of Holes in Glulam Beams Using Self-tapping Screws

    … 430x150x50 beam-hanger connector under applied interstorey drift deflections based on a modified version of the CUREE loading protocol. The performance of the Megant 430x150x50 connector was evaluated and it was determined that the connector surpassed interstorey drift limits of 2.5%, outlined …

    queens Repository record for Cyclic Testing of Pre-engineered Beam-Hanger Connections & Reinforcement of Holes in Glulam Beams Using Self-tapping Screws (opens in a new tab)

  4. Δυναμική ανάλυση τρισδιάστατων μεταλλικών κατασκευών με χρήση του συστήματος Seesaw

    … involve height wise distributions for peak interstorey drift ratios (IDR), peak residual interstorey drift ratios (RIDR) and plastic hinge formations in frame elements as well as peak forces to spiral strand ropes and viscous dampers of the seesaw system. For the foundation of the steel …

    greece Repository record for Δυναμική ανάλυση τρισδιάστατων μεταλλικών κατασκευών με χρήση του συστήματος Seesaw (opens in a new tab)

  5. Effects of Connections Detailing and Friction Dissipation Devices on the Seismic Response of a Hospital Steel Braced Frame Building

    … should be designed with Rd> 2.0, while the interstorey drift at each floor is limited to 1.0%hs. Herein, Rd is the ductility-related force modification factor and hs is the storey height. Although the non-structural components and the hospital contents are not part of this research, they …

    concordia

  6. Seismic Fragility Assessment of Pre- and Post-Retrofit 1980s Concentrically Braced Frame Office Buildings in Moderate Seismic Zones

    … the engineering demand parameter (e.g. peak interstorey drift) were obtained. The analytical fragility curves of studied buildings have a lognormal distribution and are defined as a function of spectral acceleration (Sa). Both aleatoric and epistemic uncertainties were considered. The seismic …

    concordia

  7. Proposed shear wall and column areas for earthquake resistant reinforced concrete buildings

    … ductility is lower than assumed, excessive interstorey drift causes severe damage. To reduce reliance on inelastic deformation, this thesis determines the structural wall and column areas required to limit the maximum interstorey drift ratio to 1.0% under the DD-2 design earthquake. A …

    metu Repository record for Proposed shear wall and column areas for earthquake resistant reinforced concrete buildings (opens in a new tab)

  8. Inelastic drift-based approaches for preliminary seismic assessment of buildings

    … flexural-shear cantilever. Then an inelastic interstorey drift ratio model is derived from the principle of capacity spectrum analysis and modified modal pushover analysis for the assessed buildings. Numerical investigations on the representative tall wall-frame structures show that the …

    hkust Repository record for Inelastic drift-based approaches for preliminary seismic assessment of buildings (opens in a new tab)

  9. Seismic Response of Steel Frames with Bilinear and Flag Shaped Hysteretic Braces

    … Increasing these parameters generally decreased interstorey drift, residual interstorey drift, column ductility demand, beam ductility demand, and absorbed energy. However, this also had the effect of increasing acceleration and base shear. The energy dissipation parameter, β, had little effect …

    mcmaster Repository record for Seismic Response of Steel Frames with Bilinear and Flag Shaped Hysteretic Braces (opens in a new tab)

  10. Parametric study on seismic behaviour of dual-concentrically braced steel frames

    … of i) maximum floor acceleration, ii) maximum interstorey drift ratio, iii) residual interstorey drift ratio and iv) maximum beam rotation ratio (at the exterior, one-side beam-column joints) at three performance levels: design (D), near collapse (NC) and twice near collapse (2xNC). As main …

    coimbro Repository record for Parametric study on seismic behaviour of dual-concentrically braced steel frames (opens in a new tab)

  11. Fragility Assessment of Combined Heavy Timber-Steel Bracing System Through Hybrid Simulation

    … show good agreement up to 2.0 percent maximum interstorey drift. The modeling system exhibits predictable behaviour and experimental results indicate the model is conservative.

    carleton Repository record for Fragility Assessment of Combined Heavy Timber-Steel Bracing System Through Hybrid Simulation (opens in a new tab)

  12. Seismic isolation of foundations by composite liners

    … significant reduction in the accelerations and interstorey drift ratios of structures under harmonic motions while signifant drop is obtained in the spectral accelerations under earthquake motions which provide noticeable improvement in the durability of structures under dynamic effects at the …

    metu Repository record for Seismic isolation of foundations by composite liners (opens in a new tab)

  13. Evaluation of shear wall indexes for reinforced concrete buildings

    … were performed by SAP2000. Variation of roof drift and interstorey drift with shear wall ratio was obtained and results were compared with the results of approximate procedures in the literature. Additionally, performance evaluation of building models was carried out according to the linearly …

    metu Repository record for Evaluation of shear wall indexes for reinforced concrete buildings (opens in a new tab)

  14. Numerical Simulations of Steel Frames Equipped with Friction-Damped Diagonal-Bracing Devices

    … the demand of the primary frame system, the interstorey drift, and control the damage of non-structural components as building envelope. Regarding to their mechanical behavior, friction dampers dissipate energy through the relative sliding of plates clamped with post-tensioned bolts, while …

    concordia

  15. Design of gravity-load frames for seismic deformation demands in highrise concrete buildings with shear walls in Canada

    … explores various methods to apply the specified interstorey drift envelope from CSA A23.3 to shear wall buildings' GLRF. It offers practical recommendations for using the computer program ETABS to impose the necessary lateral displacements. The thesis includes a comprehensive building design case …

    ubc Repository record for Design of gravity-load frames for seismic deformation demands in highrise concrete buildings with shear walls in Canada (opens in a new tab)

  16. Timber vertical additions for improving seismic resilience of existing buildings

    … tuned configurations can achieve reductions in interstorey drift of up to 20%, while maintaining robustness against record-to-record variability.

    trento Repository record for Timber vertical additions for improving seismic resilience of existing buildings (opens in a new tab) Embargoed

  17. The Effects of Ground Motions Characteristics and Higher Modes on the Seismic Response of Steel Strongback Braced Frame Buildings

    … of buildings were expressed in terms of interstorey drift (ISD), residual interstorey drift (RISD), floor acceleration (FA) and storey shear. To identify the types of failure mechanism, the incremental dynamic analysis (IDA) was employed and the IDA curves were developed considering both …

    concordia

  18. Clt infill panels in steel moment resisting frames as a hybrid seismic force resisting system

    … to examine the effect of infill panels on the interstorey drift of the three, six, and nine storey. The ultimate and yield strength and drift capacity are determined and used to determine the overstrength and ductility factors as described in the National Building Code of Canada 2010.

    ubc Repository record for Clt infill panels in steel moment resisting frames as a hybrid seismic force resisting system (opens in a new tab)

  19. Design, Modelling, and Seismic Performance of Outrigger Braced Frame Steel Buildings Subjected to Crustal and Subduction Earthquakes

    … MD-CBF buildings, and they experienced lower interstorey drift and residual interstorey drift than the MD-CBF buildings. In all case studies considered here, the collapse margin ratio (CMR) is greater for buildings subjected to crustal ground motions than subduction ground motions. Evaluation …

    concordia

  20. Torsional response of reinforced concrete frame buildings subjected to blast loading

    … of structure was evaluated by considering interstorey drift, floor rotations, lateral displacements, and P-M capacity/demand ratios for columns. The results indicate that the perimeter columns, especially the corner columns are affected most when the building is subjected to blast loadings. …

    ottawa-retro Repository record for Torsional response of reinforced concrete frame buildings subjected to blast loading (opens in a new tab)

Page 1 of 3