Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 23 for “"intrafraction"”

  1. The effects of intrafraction motion on dose heterogeneity

    Intrafraction motion has long been suspected of causing inaccuracies in the resultant dose delivered to the patient. This study attempts to determine how breathing motion affects intact-breast cancer patients for three different treatment techniques commonly used in the clinic: physical wedge …

    sask Repository record for The effects of intrafraction motion on dose heterogeneity (opens in a new tab)

  2. Dosimetric impact of prostate intrafraction motion during hypofractionated prostate cancer radiotherapy

    … d’un dispositif pour contrôler les mouvements intrafraction de la prostate pourrait contribuer à réduire ces marges de traitement, diminuant ainsi le risque de toxicité. Les incertitudes géométriques liées aux changements anatomiques et aux mouvements inter et intrafraction de la prostate …

    star-france Repository record for Dosimetric impact of prostate intrafraction motion during hypofractionated prostate cancer radiotherapy (opens in a new tab)

  3. Quantifying intrafraction organ motion and its impact on prostate and lung radiotherapy

    It is well known, that intrafractional tumor motion can be remarkable in prostate and lung radiotherapy, but the clinical impact on single patients and patient populations is still under investigation. In this work, real-time motion data of implanted transponders gathered with an electromagnetic …

    heid-diss Repository record for Quantifying intrafraction organ motion and its impact on prostate and lung radiotherapy (opens in a new tab)

  4. Inter- and Intrafraction Motion Management for MR guided Proton Therapy of Pancreatic Carcinoma

    Hintergrund: Patienten mit Bauchspeicheldrüsenkrebs könnten von der Protonentherapie (PT) profitieren, aufgrund ihres Potentials der Schonung von Risikoorganen. Jedoch führen die inter- und intrafraktionelle Beweglichkeit der Bauchspeicheldrüse zu hohen Unsicherheiten bei der Dosisapplikation und …

    qucosa-diss Repository record for Inter- and Intrafraction Motion Management for MR guided Proton Therapy of Pancreatic Carcinoma (opens in a new tab)

  5. A method for validating a transperineal ultrasound system for intrafraction monitoring of the prostate during external beam radiotherapy

    Introduction: The Clarity Autoscan 40 transperineal ultrasound (TPUS) system (Eiekta, Sweden) for prostate motion management employs a vertically-oriented 20 ultrasound array that is continuously swept mechanically to repeatedly produce 30 images containing the prostate [1]. The target position …

    adelaide Repository record for A method for validating a transperineal ultrasound system for intrafraction monitoring of the prostate during external beam radiotherapy (opens in a new tab)

  6. Automated review of patient position during DIBH breast hybrid IMRT using EPID images

    … at the lung-rib interface. The setup error and intrafraction motion were measured for all fractions of 20 left-sided breast patients, 10 treated with fields with no multi-leaf collimator (MLC) shielding and 10 with MLCs used for shielding. Setup error measurements were also collected for the …

    manitoba Repository record for Automated review of patient position during DIBH breast hybrid IMRT using EPID images (opens in a new tab)

  7. Effective Dose Gradients in Lung Radiotherapy: Setting Target Margins and Monitoring Dose Deviations for Image-Guided Adaptive Strategies

    … delivery of radiation therapy is referred to as intrafraction organ motion. Intrafraction motion is most predominant in the lungs due to the respiratory motion of the diaphragm and lungs. This intrafraction motion presents a substantial challenge to physicists and clinicians interested in the …

    waterloo Repository record for Effective Dose Gradients in Lung Radiotherapy: Setting Target Margins and Monitoring Dose Deviations for Image-Guided Adaptive Strategies (opens in a new tab)

  8. Real-time tumor localization with electromagnetic transponders for image-guided radiotherapy applications

    The detection of intrafraction organ motion, necessary for the minimization of treatment errors, is a remaining challenge in radiotherapy. A novel technology for the dynamic monitoring of tumor motion uses tumor-implanted electromagnetic (EM) transponders. In the present thesis, concepts and …

    heid-diss Repository record for Real-time tumor localization with electromagnetic transponders for image-guided radiotherapy applications (opens in a new tab)

  9. A Novel Collimator Concept for Fast Rotational IMRT

    … of the collimator on the one hand, and to intrafraction motion on the other hand. Both aspects have been investigated in additional MC studies. The results of the planning studies showed that the 2D-bMLC concept is in principal adequate for rotational radiotherapy treatments with potential …

    heid-diss Repository record for A Novel Collimator Concept for Fast Rotational IMRT (opens in a new tab)

  10. Real-Time Ultrasound Image-Guidance and Tracking in External Beam Radiotherapy

    … and some probe position. - To evaluate the intrafraction motion of prostate by collecting and analyzing ultrasound monitoring data from some patients. - To evaluate the accuracy of Clarity (Anticosti) system by using 3D phantom programmed with sinusoidal and breathing movement patterns to …

    heid-diss Repository record for Real-Time Ultrasound Image-Guidance and Tracking in External Beam Radiotherapy (opens in a new tab)

  11. Validation of calypso surface beacons for deep inspiration breath hold radiotherapy

    … considered clinically insignificant. Volunteer intrafraction error was dominated by inconsistency in achieving target DIBH levels. No statistically significant difference in breath hold consistency or variance was found across the volunteers between coaching methods. Mean intrafraction errors in …

    manitoba Repository record for Validation of calypso surface beacons for deep inspiration breath hold radiotherapy (opens in a new tab)

  12. Residual Set-up Error for Canine Brain Radiation Therapy

    … to account for interfraction (set-up errors) and intrafraction motion (such as motion due to respiration). The size of the PTV margin is an estimate of the targeting accuracy that can be achieved using immobilization devices and image guidance. The PTV margin reported for stereotactic radiation …

    sask Repository record for Residual Set-up Error for Canine Brain Radiation Therapy (opens in a new tab)

  13. Improving the accuracy of Particle Therapy in lung cancer through the development of integrated-mode particle imaging technology

    … are very susceptible to degradation from intrafraction organ motion particularly in the treatment of lung cancer. This work proposes that particle imaging, a technique that uses the transmission of particle beams to form radiological images, could be used to reduce this impact. An …

    ucl Repository record for Improving the accuracy of Particle Therapy in lung cancer through the development of integrated-mode particle imaging technology (opens in a new tab)

  14. Real-time organ motion management in MRI-guided radiotherapy

    … modeling and optimization approaches for intrafraction motion management in the literature, the previously developed approaches are not designed to take advantage of the real-time anatomical information to continuously monitor the dose delivery and, if warranted, correct for any potential …

    wichita-thes Repository record for Real-time organ motion management in MRI-guided radiotherapy (opens in a new tab)

  15. Cardiac synchronized volumetric modulated arc therapy

    … and efficient treatment option for arrhythmias. Intrafraction heart motion, however, must be accounted for to ensure accurate dose delivery to the target region. Our technique aims to minimize the dose delivered to normal tissues by synchronizing beam delivery with a cardiac signal, irradiating …

    ubc Repository record for Cardiac synchronized volumetric modulated arc therapy (opens in a new tab)

  16. Making The Right Decisions for Adaptive Radiotherapy

    … were evaluated per fraction: displacement, intrafraction Dice, interfraction Dice, objective scores for targets and organs at risk (OARs), and a radiobiology score, with a composite radar area summarizing overall deviation. Results: Verification demonstrated strong agreement between the …

    lsu-thes Repository record for Making The Right Decisions for Adaptive Radiotherapy (opens in a new tab)

  17. Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning and Delivery of Early-Stage Non-Small Cell Lung Cancer

    … to accurately predict internal target motion. Intrafraction triggered kV imaging was validated in a programmable motion phantom study as a method to determine how correlated the internal and external motion are during ungated and gated VMAT deliveries and to identify potential phase shifts …

    uwo Repository record for Optimizing Respiratory Gated Intensity Modulated Radiation Therapy Planning and Delivery of Early-Stage Non-Small Cell Lung Cancer (opens in a new tab)

  18. Respiratory and Breath Hold Motion in Contemporary Breast Irradiation: Dosimetric Impact and Management Techniques

    … tomography image that does not account for intrafraction motion during treatment. Motion during breast radiotherapy can result in suboptimal plan quality, decreased target coverage, and increased dose to organs at risk. This thesis examines two sources of respiratory motion during breast …

    calgary Repository record for Respiratory and Breath Hold Motion in Contemporary Breast Irradiation: Dosimetric Impact and Management Techniques (opens in a new tab)

  19. Patient Motion Management with 6DOF Robotics for Frameless and Maskless Stereotactic Radiosurgery

    … Our solution is to monitor and compensate for intrafraction head motion in 6 degrees-of-freedom (6DOF) in real-time using an in-house designed and built parallel kinematics robotic motion compensation system. To that end, we present the research and set of experiments required to reach this …

    chicago-thes Repository record for Patient Motion Management with 6DOF Robotics for Frameless and Maskless Stereotactic Radiosurgery (opens in a new tab)

Page 1 of 2