Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 11 of 11 for “"intrafractional motion"”

  1. Real Time Prostate Motion Tracking Using the Portal Imaging Device in Radiation Therapy

    Intrafractional motion management is the key step in image-guided radiation therapy. Prostate location can change vastly during treatment. This work is to provide a way to implement and facilitate real-time MV tumor surrogate tracking of the fiducial marker implanted for prostate cancer treatment. …

    buffalo Repository record for Real Time Prostate Motion Tracking Using the Portal Imaging Device in Radiation Therapy (opens in a new tab)

  2. New Methods for Motion Management During Radiation Therapy

    … new image-based techniques for the management of intrafractional motion during radiation therapy are presented. Intra-fractional motion describes all kinds of anatomy changes - most prominently respiration - that occur during a single treatment session. Spatially confining the radiation dose to …

    heid-diss Repository record for New Methods for Motion Management During Radiation Therapy (opens in a new tab)

  3. Dosimetric Verification of Respiratory-Gated Radiation Therapy using a Dynamic Phantom for Commissioning the Varian Real-Time Position Management System

    … abdominal cavities are subject to respiratory motion which can cause the undesired effect of moving the target out of the radiation field. A possible result from this type of motion is under-dosing the target and over-dosing the surrounding normal tissue. Respiratory-Gated Radiotherapy (RGRT) …

    ohiolink Repository record for Dosimetric Verification of Respiratory-Gated Radiation Therapy using a Dynamic Phantom for Commissioning the Varian Real-Time Position Management System (opens in a new tab)

  4. Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct

    Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and …

    uthsc Repository record for Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct (opens in a new tab)

  5. Real-Time Ultrasound Image-Guidance and Tracking in External Beam Radiotherapy

    … probe position. - To evaluate the intrafraction motion of prostate by collecting and analyzing ultrasound monitoring data from some patients. - To evaluate the accuracy of Clarity (Anticosti) system by using 3D phantom programmed with sinusoidal and breathing movement patterns to simulate …

    heid-diss Repository record for Real-Time Ultrasound Image-Guidance and Tracking in External Beam Radiotherapy (opens in a new tab)

  6. Comparative Motion and Dosimetric Analysis of Organs at Risk near Pancreatic Tumors Treated with Stereotactic Body Radiation Therapy with and without Abdominal Compression using 4DCT Datasets

    … compression (AC) may be used to control tumor motion during radiation therapy treatments for patients with tumors near the diaphragm. Inadvertently treating with AC using plans designed without AC, or vice versa, may result in differences in planned dose to normal tissue and target coverage. …

    ohiolink Repository record for Comparative Motion and Dosimetric Analysis of Organs at Risk near Pancreatic Tumors Treated with Stereotactic Body Radiation Therapy with and without Abdominal Compression using 4DCT Datasets (opens in a new tab)

  7. Surface guided radiotherapy

    … In turn, accurate patient localization and motion management becomes more important. Several image guidance systems are available for radiotherapy (RT), with 3-dimensional (3D) volumetric images with cone beam computed tomography (CBCT) as a gold standard. In recent years, surface imaging …

    lund Repository record for Surface guided radiotherapy (opens in a new tab)

  8. Clinical implementation of quality-assured and optimized pencil beam scanning proton therapy for moving targets

    … therapy for targets undergoing respiratory motion is limited due to uncertainties in the delivered dose caused by motion and interplay effects. The assessment of the delivered dose distributions including these motion effects as well as treatment planning with sufficient robustness against …

    qucosa-diss Repository record for Clinical implementation of quality-assured and optimized pencil beam scanning proton therapy for moving targets (opens in a new tab)

  9. Experimental assessments of intrafractional prostate motion on radiation boosts to a dominant intra-prostatic cancer lesion

    We investigated the impact of intrafractional prostate motion on radiation dose distributions to the whole prostate with boosts to a dominant intra-prostatic cancer lesion (DIL) from sequential boost plans (separate prostate and boost plans) and simultaneous boost plans (single prostate and boost …

    uwo Repository record for Experimental assessments of intrafractional prostate motion on radiation boosts to a dominant intra-prostatic cancer lesion (opens in a new tab)

  10. Tumor Autocontouring and Motion Prediction for Non-Invasive Intrafractional Tumor-Tracked Radiotherapy on a Linac-MR

    Intrafractional tumor motion presents a significant challenge to delivering conformal doses to the tumor while maximizing the sparing of the surrounding healthy tissues. The recently developed hybrid linac-MR systems are capable of intrafractional MR imaging and concurrent delivery of therapeutic …

    alberta Repository record for Tumor Autocontouring and Motion Prediction for Non-Invasive Intrafractional Tumor-Tracked Radiotherapy on a Linac-MR (opens in a new tab)