Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 1,192 for “"intraocular"”

  1. Intraocular Pressure Dynamics

    … over 70 million people worldwide [1]. Elevated intraocular pressure (IOP) and age are the primary risk factors for glaucoma [2] and lowering IOP is the only proven treatment for the disease [3]. IOP and its fluctuations affect nearly every aspect of ocular physiology and homeo-stasis, as well as …

    uab Repository record for Intraocular Pressure Dynamics (opens in a new tab)

  2. Accommodation and intraocular pressure

    The relationship between accommodation and intraocular pressure (lOP) has not been addressed as a research question for over 20 years, when measurement of both of these parameters was less advanced than today. Hence the central aim of this thesis was to evaluate the effects of accommodation on lOP. …

    aston Repository record for Accommodation and intraocular pressure (opens in a new tab)

  3. Beta-adrenoceptors and intraocular pressure

    … world. This disease is characterised by raised intraocular pressure (I. O. P. ) leading to progressive vision loss. Topical beta blockers decrease aqueous production and therefore lower I. O. P. How beta blockers decrease aqueous production is not known. It is presumed they exert their I. O. P. …

    glasgow Repository record for Beta-adrenoceptors and intraocular pressure (opens in a new tab)

  4. Evaluation of modern intraocular lenses

    Accommodating Intraocular Lenses (IOLs), multifocal IOLs (MIOLs) and toric IOLs are designed to provide a greater level of spectacle independency post cataract surgery. All of these IOLs are reliant on the accurate calculation of intraocular lens power determined through reliable ocular biometry. A …

    aston Repository record for Evaluation of modern intraocular lenses (opens in a new tab)

  5. Intraocular light scattering and glare testing

    … we can explain the disagreements whether the intraocularly scattered light has a wavelength dependence or not. A wavelength dependency with opposite sign was found in agreement with psychophysical findings. Correlation between angular distribution and wavelength was found only when compared to …

    goteborg Repository record for Intraocular light scattering and glare testing (opens in a new tab)

  6. Aspheric intraocular lens in cataract surgery

    … critical analysis of 6 publications on aspheric intraocular lenses (IOLs) carried out at St. Thomas’ Hospital, Guy’s & St. Thomas’ NHS Foundation Trust, London between 2006 2012. The focus is on two areas: the visual and optical performance of aspheric IOLs with different values of asphericity, …

    city-london Repository record for Aspheric intraocular lens in cataract surgery (opens in a new tab)

  7. Analysis of the intraocular pressure pulse

    … hypothesis were attempted. 3. The nature of the intraocular pressure pulse in health and disease and its relation to systemic cardiovascular variables. Fourier analysis and traditional parameters were applied to the IOP pulse measurements taken on diseased and healthy eyes. Only the derived …

    aston Repository record for Analysis of the intraocular pressure pulse (opens in a new tab)

  8. Microfabrication of an intraocular pressure sensor

    Thesis (M.S.)--Michigan State University. Department of Electrical and Computer Engineering, 2005

    msu Repository record for Microfabrication of an intraocular pressure sensor (opens in a new tab)

  9. Eye modelling for personalised intraocular lens design

    … cataractous lens and implanting an artificial intraocular lens (IOL). Modern technologies used to treat cataract are highly sophisticated and the operation involves remarkable skills; however the IOL power calculation in certain circumstances can be unsatisfactory. Currently the calculation of …

    galway Repository record for Eye modelling for personalised intraocular lens design (opens in a new tab)

  10. Síntese de Implantes Biodegradáveis para Aplicação Intraocular

    … de fármaco (SLCF) para posterior aplicação intraocular. Para a síntese de implantes biodegradáveis foram utilizados polímeros como a poli-ε-caprolactona (PCL) e o Lutrol F127, ambos promissores na área da medicina quando aplicados em SLCF. O desenvolvimento de SLCF biodegradáveis tem sido …

    coimbro Repository record for Síntese de Implantes Biodegradáveis para Aplicação Intraocular (opens in a new tab)

  11. Transcriptional plasticity of microglia during intraocular inflammation

    Microglia are a tissue-resident immune cell of the central nervous system known to possess functions involved in immune surveillance and tissue homeostasis. Transcriptomics has characterised microglia and enabled discovery of microglial heterogeneity in addition to core microglial transcriptional …

    bristol Repository record for Transcriptional plasticity of microglia during intraocular inflammation (opens in a new tab)

  12. Hialuronidasa y presión intraocular. Trabajo clínico – Experimental

    … como es la fisiopatología de la hipertensión intraocular, al que tanto trabajo y atención se viene dedicando en la Clínica Universitaria oftalmológica de Sevilla, desde hace más de quince años. Consta de dos partes, una primera de carácter clínico, en la que es estudió el comportamiento de la …

    sevilla Repository record for Hialuronidasa y presión intraocular. Trabajo clínico – Experimental (opens in a new tab)

  13. Optical Performance Test & Analysis of Intraocular Lenses

    … and implantation of an artificial lens called an intraocular lens(IOL). The designs of the IOLs have shown improvements over the years to further imitate natural human vision. A need for an objective testing and analysis tool for the latest IOLs grow with the advancements of the IOLs.In this …

    arizona-thes Repository record for Optical Performance Test & Analysis of Intraocular Lenses (opens in a new tab)

  14. Intraocular Pressure Sensing and Control for Glaucoma Research

    … with experimental costs. Available methods of intraocular pressure (IOP) elevation are not always successful, the amplitude and time course of IOP changes are unpredictable and irreversible, and IOP measurement by tonometry is laborious. This dissertation focuses on the development and …

    usf Repository record for Intraocular Pressure Sensing and Control for Glaucoma Research (opens in a new tab)

  15. Toward a drug delivery coating for intraocular lenses

    … used to create a multi-drug delivery coating for intraocular lenses (IOL). The establishment of a drug delivery coating for intraocular lenses required key advances in ultrathin film technology. This thesis focused on rational polymer design for tailored release, incorporation of hydrophobic small …

    mit Repository record for Toward a drug delivery coating for intraocular lenses (opens in a new tab)

  16. Treatment of Intraocular Lymphoma Using Biodegradable Microneedle Implant

    Intraocular lymphoma (IOL) needs a long term therapy and its treatment protocol has not been well established. A controlled drug release micro-implant, implantable in scleral pocket in the pars plana region of the eye, is considered to treat IOL as it allows sustained release of therapeutic levels …

    ohiolink Repository record for Treatment of Intraocular Lymphoma Using Biodegradable Microneedle Implant (opens in a new tab)

Page 1 of 60