Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"intraoral scan"”.

  1. New Impressions of the Intraoral Scan in Oral & Maxillofacial Surgery

    The intraoral scanner (IOS) is increasingly used in dentistry. Instead of a traditional dental impression, the IOS creates an accurate 3D representation of teeth and gums. This thesis shows that the scanner can precisely and reliably measure not only dental structures but also color and shape …

    radboud Repository record for New Impressions of the Intraoral Scan in Oral & Maxillofacial Surgery (opens in a new tab) Download PDF for New Impressions of the Intraoral Scan in Oral & Maxillofacial Surgery (opens in a new tab)

  2. A Comparison of Orthodontic Intraoral Scan Results Between Staff and Volunteers

    … first to assess and compare a trained staff’s intraoral scan to a clinical examination by comparing the overbite, overjet, Angle canine and molar classification, and gingival health. The second part of this study is to determine if the self-scan scan from a patient is as reliable to the staff’s …

    unlv Repository record for A Comparison of Orthodontic Intraoral Scan Results Between Staff and Volunteers (opens in a new tab) Download PDF for A Comparison of Orthodontic Intraoral Scan Results Between Staff and Volunteers (opens in a new tab)

  3. An Evaluation of Root Length Change Measurements using Intraoral Scan and Panoramic Radiographs

    … over the course of orthodontic treatment, using intraoral scans of crowns, and a mathematical model to account for distortions in the radiographs. The study additionally evaluated whether a best-fit equation could be created from the calculated data to minimize differences to the measurements of …

    loma-linda Repository record for An Evaluation of Root Length Change Measurements using Intraoral Scan and Panoramic Radiographs (opens in a new tab)

  4. Characteristics of intraoral scan bodies and their influence on impression accuracy: A systematic review

    Σκοπός της παρούσας συστηματικής ανασκόπησης είναι να αξιολογήσει την επίδραση των διαφόρων χαρακτηριστικών των αξόνων ενδοστοματικής σάρωσης (ΑΕΣ) στην αποτυπωτική ακρίβεια της ψηφιακής ενδοστοματικής σάρωσης. Υλικά και Μέθοδος: Πραγματοποιήθηκε ηλεκτρονική αναζήτηση στις επιστημονικές βάσεις …

    athens Repository record for Characteristics of intraoral scan bodies and their influence on impression accuracy: A systematic review (opens in a new tab)

  5. Digital scan to enhance patient education

    … of this study was to evaluate if the use of a 3D intraoral scan as a visual aid improves a patient’s communication self-efficacy and risk-literacy concerning their periodontal disease status. Methods: This study used a parallel experimental research design and collected quantitative data through a …

    eastern-wash Repository record for Digital scan to enhance patient education (opens in a new tab)

  6. THE HARD AND SOFT TISSUE DIMENSIONAL CHANGES FOLLOWING EXTRACTION AND RIDGE PRESERVATION WITH DIFFERENT MEMBRANES – A PILOT STUDY

    … amnion-chorion membrane (DHDA-C). An intraoral scan was obtained before the extraction. Immediately following the extraction, a Cone Beam CT was taken to evaluate the extraction socket (Initial-CT). 4 months after ARP, a second CBCT(Post-CT) and an intraoral scan were obtained. …

    penn Repository record for THE HARD AND SOFT TISSUE DIMENSIONAL CHANGES FOLLOWING EXTRACTION AND RIDGE PRESERVATION WITH DIFFERENT MEMBRANES – A PILOT STUDY (opens in a new tab)

  7. Impact of Maximal and Minimal Mouth Opening on Mandibular Flexure via Scanning

    … affects prosthodontic outcomes, but digital scanner research is limited. Methods: Seventy dental students (35 males, 35 females) had two impressions taken: one with maximum and one with minimum mouth opening. Results: First molars showed higher deviations than premolars. Females had larger …

    loma-linda Repository record for Impact of Maximal and Minimal Mouth Opening on Mandibular Flexure via Scanning (opens in a new tab)

  8. Invisalign ClinCheck Prescribed versus Performed Interproximal Reduction

    … For 32 of 57 subjects with an additional intraoral scan prior to refinement, mesiodistal tooth width measurements were recorded using OrthoCAD software and digital caliper. Measurement difference between pre-treatment and refinement indicated the amount of interproximal reduction …

    temple Repository record for Invisalign ClinCheck Prescribed versus Performed Interproximal Reduction (opens in a new tab)

  9. Effect of Splinting Implant Scan Bodies Intraorally on The Trueness of Complete Arch Digital Impressions: A Clinical Study

    … study was to investigate the effect of splinting scan bodies intraorally on the trueness and scan time of implant digital impressions of the edentulous arch. Materials and Methods: Nineteen edentulous jaws undergoing fixed complete denture treatment with a minimum of 4 implants were selected for …

    loma-linda Repository record for Effect of Splinting Implant Scan Bodies Intraorally on The Trueness of Complete Arch Digital Impressions: A Clinical Study (opens in a new tab)

  10. Optical accuracy assessment of fully guided Yomi implant surgery in partially edentulous cases

    … using both pre-operative and post-operative CBCT scans to compare deviations. This study introduces a new method of intraoral scanning to evaluate the accuracy of implant positioning. The objective was to design a reproducible and quantifiable method for evaluating implant placement with the …

    bu Repository record for Optical accuracy assessment of fully guided Yomi implant surgery in partially edentulous cases (opens in a new tab)

  11. EFFICACY OF CARIES DETECTION AND CHARACTERIZATION USING NEAR-INFRARED IMAGING TECHNOLOGY IN THE ITERO ELEMENT 5D INTRAORAL SCANNER IN COMPARISON TO CLINICAL-REFERENCE STANDARD BITEWING RADIOGRAPHS IN A PEDIATRIC POPULATION

    … radiographic detection. The new iTero Element 5D intraoral scanner (Align Technology) has integrated NIRI capture and viewing technology but has not been specifically studied in a pediatric population. Therefore, the goal of this study was to assess clinicians’ abilities to detect and characterize …

    u-pacific Repository record for EFFICACY OF CARIES DETECTION AND CHARACTERIZATION USING NEAR-INFRARED IMAGING TECHNOLOGY IN THE ITERO ELEMENT 5D INTRAORAL SCANNER IN COMPARISON TO CLINICAL-REFERENCE STANDARD BITEWING RADIOGRAPHS IN A PEDIATRIC POPULATION (opens in a new tab)

  12. Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient preference

    … made from alginate impressions, which are either scanned directly or poured in plaster and then scanned. The development of chairside oral scanners now allows direct intraoral scanning of the dentition, but questions remain regarding the accuracy of full-arch digital models acquired using this …

    umn Repository record for Clinical use of a direct chairside oral scanner: an assessment of accuracy, time, and patient preference (opens in a new tab)

  13. Reliability and Accuracy of a Novel Photogrammetric Orthodontic Monitoring System

    … an established reference. Materials and Methods: Intraoral scans (True Definition Scanner, 3MTM) and video scans (iPhone 7, AppleTM) were taken of 30 subjects undergoing comprehensive orthodontic treatment at Loma Linda University’s Graduate Orthodontic Clinic at T1 (initial) and T2 (3 months …

    loma-linda Repository record for Reliability and Accuracy of a Novel Photogrammetric Orthodontic Monitoring System (opens in a new tab)

  14. Assessment of Surgical Guide Accuracy Utilizing a Digital Workflow

    … using two methods: a post-operative CBCT scan and an intraoral scan of implant scan bodies. Each set of files were overlapped with the treatment evaluation tool of the coDiagnostiX software, to compare the planned to the resulting implant position.;Results: The average error was more …

    wvu Repository record for Assessment of Surgical Guide Accuracy Utilizing a Digital Workflow (opens in a new tab)

  15. Palatal Volumetric Change Analysis Following Subepithelial Connective Tissue Graft Harvesting with Donor Site Augmentation: A Randomized Controlled Trial

    … changes were assessed by superimposing the intraoral scan of the palate pre-operatively, 2-, 4-, and 6- month post-operatively. Based on the power analysis, the aim is to have 40 participants in total (minimum of 12 per group). Inter-group and intra-group statistical analysis was conducted …

    tamu Repository record for Palatal Volumetric Change Analysis Following Subepithelial Connective Tissue Graft Harvesting with Donor Site Augmentation: A Randomized Controlled Trial (opens in a new tab) Embargoed until 2027-05-01

  16. Accuracy of Intraoral Scanners with Different Total Occlusal Convergence Angles: An In-Vitro Study

    Digital intraoral imaging has become more utilized in contemporary dental practice. This is performed using an intraoral scanner and it can be used as an alternative to making conventional impressions when indicated. This technology has many advantages, such as decreasing the number of appointments …

    loma-linda Repository record for Accuracy of Intraoral Scanners with Different Total Occlusal Convergence Angles: An In-Vitro Study (opens in a new tab)

  17. A randomized controlled trial to compare the histomorphometric and clinical outcomes of soft tissue augmentation at the time of lateral ridge augmentation procedures

    … A cone beam computed tomography (CBCT) scan and intraoral scan were obtained prior to both surgical procedures. Surgery 1 involved GBR and soft tissue grafting, if applicable. After a healing period of at least 6 months, surgery 2 involved a soft tissue biopsy from the augmented site and …

    uab Repository record for A randomized controlled trial to compare the histomorphometric and clinical outcomes of soft tissue augmentation at the time of lateral ridge augmentation procedures (opens in a new tab)

Page 1 of 2