  1. Comparing effectiveness of intraoral scanner in caries detection

    … who is interpreting them. That is where digital intraoral scanners (IOS) come in. These scanners offer high-resolution imaging and real-time analysis, making them a promising tool for spotting cavities more accurately. However, concerns regarding their diagnostic accuracy, specificity, and …

    temple Repository record for Comparing effectiveness of intraoral scanner in caries detection (opens in a new tab)

  2. Reproducibility of Dental Bite Registrations Using A Direct Intraoral Scanner

    … aim of this study was to determine if a direct intraoral scanner is a reliable method to record dental bite registrations. Methods: Intraoral scans and bite registrations were taken on 41 adult patients at an initial time point (T1) and at a second time point (T2), one week later, using the …

    umn Repository record for Reproducibility of Dental Bite Registrations Using A Direct Intraoral Scanner (opens in a new tab)

  3. Detecting erosive wear using an intraoral scanner and different methods of scan alignment

    Σκοπός: Η αξιολόγηση διαβρωτικών βλαβών που προκλήθηκαν από διαφορετικά ενεργειακά ποτά με τη βοήθεια ενδοστοματικού σαρωτή και κλινικών δεικτών. Επίσης, η σύγκριση διαφορετικών μεθόδων αλληλεπίθεσης μοντέλων. Μέθοδος: Εξαγμένα ανθρώπινα δόντια χωρίς βλάβες εγκιβωτίστηκαν σε έξι μοντέλα δίκην μισής …

    athens Repository record for Detecting erosive wear using an intraoral scanner and different methods of scan alignment (opens in a new tab)

  4. Influence of gingival retraction on the accuracy of an intraoral scanner for subgingival finish lines

    … gingival displacement on the accuracy of an intraoral scanner (IOS) with 0.5 and 1mm subgingival finish lines. Materials and Methods: A 3D printed resin dental model was fabricated with a removable milled zirconia die of tooth #46 full crown preparation and 3D printed resin gingiva. A …

    ubc Repository record for Influence of gingival retraction on the accuracy of an intraoral scanner for subgingival finish lines (opens in a new tab) Download PDF for Influence of gingival retraction on the accuracy of an intraoral scanner for subgingival finish lines (opens in a new tab)

  5. Accuracy of scanning partially edentulous mandibular arches using an intraoral scanner : an in-vitro pilot study

    Purpose: The study examined the accuracy of intraoral scanning of partially edentulous dental models. Materials and Methods: A mandibular dentoform with 16 individual acrylic teeth was used to remove specific dental units to create the four models of partially edentulous Kennedy classes. In all …

    ubc Repository record for Accuracy of scanning partially edentulous mandibular arches using an intraoral scanner : an in-vitro pilot study (opens in a new tab) Download PDF for Accuracy of scanning partially edentulous mandibular arches using an intraoral scanner : an in-vitro pilot study (opens in a new tab)

  6. Investigation of an Intraoral Scanner and Analysis Workflows for Measuring Surface Loss on Planar and Freeform Surfaces <i>in vitro</i>

    … the accuracy and measurement thresholds of an intraoral scanner, IOS-TD (True Definition, Midmark Corp., Ohio, USA) for measuring surface change on planar and freeform surfaces such as seen in polished and natural enamel.<br/><br/><b>Methods</b> – The IOS-TD’s accuracy for measuring a groove on …

    kings Repository record for Investigation of an Intraoral Scanner and Analysis Workflows for Measuring Surface Loss on Planar and Freeform Surfaces <i>in vitro</i> (opens in a new tab) Download PDF for Investigation of an Intraoral Scanner and Analysis Workflows for Measuring Surface Loss on Planar and Freeform Surfaces <i>in vitro</i> (opens in a new tab)

  7. Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática

    … models generated by two scanning techniques (intraoral scanner - Itero 5d Element® - and desktop scanner -Straumann ®) of an experimental model of the upper arch (Nacional Ossos ®) made of polyurethane and the plaster model obtained from this arch. Points A – 3mm above element 17; B – 3mm …

    brazil-ufrn Repository record for Avaliação da acurácia dos modelos dentários digitais obtidos para cirurgia ortognática (opens in a new tab)

  8. EFFICACY OF CARIES DETECTION AND CHARACTERIZATION USING NEAR-INFRARED IMAGING TECHNOLOGY IN THE ITERO ELEMENT 5D INTRAORAL SCANNER IN COMPARISON TO CLINICAL-REFERENCE STANDARD BITEWING RADIOGRAPHS IN A PEDIATRIC POPULATION

    … radiographic detection. The new iTero Element 5D intraoral scanner (Align Technology) has integrated NIRI capture and viewing technology but has not been specifically studied in a pediatric population. Therefore, the goal of this study was to assess clinicians’ abilities to detect and characterize …

    u-pacific Repository record for EFFICACY OF CARIES DETECTION AND CHARACTERIZATION USING NEAR-INFRARED IMAGING TECHNOLOGY IN THE ITERO ELEMENT 5D INTRAORAL SCANNER IN COMPARISON TO CLINICAL-REFERENCE STANDARD BITEWING RADIOGRAPHS IN A PEDIATRIC POPULATION (opens in a new tab)

  9. Accuracy of Digital Impressions at Varying Implant Depths: An In-vitro Study

    … of visible scannable surface of a scan body. Intraoral scanner technology uses advanced optical principles to record the surface of the scan body to accurately capture the implant position. Purpose: To investigate the effect implant placement depth has on the accuracy of digital implant …

    wvu Repository record for Accuracy of Digital Impressions at Varying Implant Depths: An In-vitro Study (opens in a new tab)

  10. Accuracy of Intraoral Scanners with Different Total Occlusal Convergence Angles: An In-Vitro Study

    Digital intraoral imaging has become more utilized in contemporary dental practice. This is performed using an intraoral scanner and it can be used as an alternative to making conventional impressions when indicated. This technology has many advantages, such as decreasing the number of appointments …

    loma-linda Repository record for Accuracy of Intraoral Scanners with Different Total Occlusal Convergence Angles: An In-Vitro Study (opens in a new tab)

  11. A Digital Assessment of Centric Relation Precision

    … virtual recordings of these methods taken by an intraoral scanner. The purpose of this study was to assess the digital precision of the swallow, chin-point guidance, and bimanual manipulation centric relation positioning techniques.Materials and Methods: Ten participants were included in the …

    marquette Repository record for A Digital Assessment of Centric Relation Precision (opens in a new tab)

  12. New Impressions of the Intraoral Scan in Oral & Maxillofacial Surgery

    The intraoral scanner (IOS) is increasingly used in dentistry. Instead of a traditional dental impression, the IOS creates an accurate 3D representation of teeth and gums. This thesis shows that the scanner can precisely and reliably measure not only dental structures but also color and shape …

    radboud Repository record for New Impressions of the Intraoral Scan in Oral & Maxillofacial Surgery (opens in a new tab) Download PDF for New Impressions of the Intraoral Scan in Oral & Maxillofacial Surgery (opens in a new tab)

  13. Occlusal Harmony of Hand Articulated Digitally Mastered Definitive Casts Mounted in Maximal Intercuspal Position

    … the accuracy of dental restorations. The iTero intraoral scanner is emerging as a popular system in clinical practice, however the accuracy of the digitally mastered (DM) casts acquired with this system has not been evaluated. In this study, 20 scans were acquired of a simulated patient …

    tamu Repository record for Occlusal Harmony of Hand Articulated Digitally Mastered Definitive Casts Mounted in Maximal Intercuspal Position (opens in a new tab)

  14. A Comparison of Orthodontic Intraoral Scan Results Between Staff and Volunteers

    … first to assess and compare a trained staff’s intraoral scan to a clinical examination by comparing the overbite, overjet, Angle canine and molar classification, and gingival health. The second part of this study is to determine if the self-scan scan from a patient is as reliable to the staff’s …

    unlv Repository record for A Comparison of Orthodontic Intraoral Scan Results Between Staff and Volunteers (opens in a new tab) Download PDF for A Comparison of Orthodontic Intraoral Scan Results Between Staff and Volunteers (opens in a new tab)

  15. Evaluation of certai influence the durab n factors that ility of CAD/CAM restorations

    … (hybrid versus feldspar), and different scanners (extraoral and intraoral) using a micro- CT scanner and the associated software. Project 2: Crown dies were divided into two groups based on the design of the preparations to compare a modified design with round line angles to a more …

    adelaide Repository record for Evaluation of certai influence the durab n factors that ility of CAD/CAM restorations (opens in a new tab)

  16. Development of a fully digital workflow for fabricating custom nasoalveolar molding appliances

    … and palate, integrating commercially available intraoral scanning (IOS), computer-aided design/computer-aided manufacturing (CAD/CAM), and 3D printing tools. Methods: Digital dental models of three infants with cleft lip and palate were obtained using a direct intraoral scanner and compared to …

    umn Repository record for Development of a fully digital workflow for fabricating custom nasoalveolar molding appliances (opens in a new tab)

  17. Retention Of Resin Composite Cam Crowns Following Different Bonding Protocols

    … microscopy and preparations were scanned with an intraoral scanner. Crowns were milled from an experimental com-posite material with 4mm occlusal height. Teeth were randomly allocated to 12 groups (n= 10) based on the possible combinations of three surface treatments (Control, Alumina air abrasion …

    uab Repository record for Retention Of Resin Composite Cam Crowns Following Different Bonding Protocols (opens in a new tab)

  18. Effect of impression technique, connection type and implant angulation on accuracy of implant impressions for edentulous patients

    … Digital impressions were taken with an optical intraoral scanner after connecting plastic scan bodies. Standard tessellation language (STL) datasets from the 5 test groups were superimposed with STL dataset from the control cast to assess the 3-D deviations, in regards to angulation, connection …

    greece Repository record for Effect of impression technique, connection type and implant angulation on accuracy of implant impressions for edentulous patients (opens in a new tab)

  19. Evaluating the efficiency of the different resilient overdenture attachments in implant-assisted cast partial dentures

    … scanned using Prime Scan (Dentsply Sirona) intraoral scanner after hand tightened. Three models were printed, one for each attachment type, and the cast IARPDs were designed on the models. The IARPDs were constructed in the laboratory. The attachments were placed in the IARPDs. The …

    manitoba Repository record for Evaluating the efficiency of the different resilient overdenture attachments in implant-assisted cast partial dentures (opens in a new tab)

  20. Accuracy of Two Indirect Bonding Transfer Methods: A Three-Dimensional, In-vivo analysis

    … group and 99 teeth for the opaque tray group. An intraoral scanner was used to generate three-dimension .stl models of each indirect set-up ("pre-transfer"� model) and each corresponding in-vivo bracketed patient arch ("post-transfer"� model). A comparison software was used to superimpose these …

    umn Repository record for Accuracy of Two Indirect Bonding Transfer Methods: A Three-Dimensional, In-vivo analysis (opens in a new tab)