Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 151 for “"invasive measurement"”.
-
Non-invasive measurement of fluvial bedload transport velocity
A new method for measurement of bedload transport velocity using an acoustic Doppler current profiler (aDcp) is evaluated. Conventional bedload sampling involves physical samplers that are notoriously inaccurate and of limited use for characterizing the spatial and temporal distribution of bedload. …
-
Non-invasive measurement of transport effects on tigers
Thesis (M.S.)--Michigan State University. Department of Zoology, 2004
-
Non-invasive measurement techniques to monitor acoustic cavitation activity
… technologies are not suitable for this type of measurement because the sensor can be damaged and change the acoustic field in the presence of cavitation generated by the high power ultrasound. This Thesis describes the development of a non-invasive technique used to monitor acoustic cavitation …
-
Non-invasive measurement of trigeminal nerve somatosensory evoked potentials
… and 19 female) were utilized to develop a non-invasive recording capability for TSEPs. Stimulus intensity and artifact, cortical recording sites, stimulation electrode design and placement were explored. Statistically significant differences in amplitude of TSEP waveform components at 13, 19 …
-
Non-invasive measurement of respiratory mechanics and work of breathing
… in patients with airways obstruction. The direct measurement of mechanical properties is of interest as they have an obvious physical interpretation but their usefulness has as yet not been systematically tested. Resistance aside, their measurement is rarely performed as it is invasive, requiring …
-
Non-invasive measurement of markers of oxidative stress in asbestos-related lung diseases and pulmonary fibrosis
… condensate (EBC) collection is a novel, non-invasive technique to collect samples from the lung for investigating inflammatory biomarkers of lung diseases. This technique is harmless, rapid and easily repeatable which leads itself to the investigation of lung diseases such as asbestos-related …
-
Non-invasive Measurement of Cholesterol in Human Blood by Impedance Technique: an Investigation by Finite Element Field Modelling
… cholesterol levels in human blood non-invasively by electrical impedance technique. The main part of this research is focused on the development of methodologies for numerical finite element (FE) modelling of simplified blood-cholesterol system, representing a real measurement system. …
-
Effect of dense heat exchanging internals on the hydrodynamics of bubble column reactors using non-invasive measurement techniques
"Given their efficiency and capital cost reduction, bubble/slurry bubble column reactors are the reactors of choice for Fischer-Tropsch (FT) synthesis, offering clean alternative fuels and chemicals. FT synthesis is an exothermic process that requires many heat exchanging tubes in order to remove …
-
Scale-up investigation and hydrodynamics study of gas-solid fluidized bed reactor using advanced non-invasive measurement techniques
… reactors (FBRs) by implementing our advanced non-invasive measurement techniques which are gamma ray computed tomography (CT) and radioactive particle tracking (RPT) that measure local hydrodynamic parameters. Experiments were carried out in two fluidized beds of 14 cm and 44 cm in diameter using …
-
A validation and feasibility study of the non-invasive measurement of oxygen delivery and consumption after elective major abdominal surgery.
… employed in these historical studies were invasive and inconsistent with contemporary practice. V̇O2 can be measured non-invasively with indirect calorimetery, and DO2 calculated from non-invasive cardiac output monitors, and haemoglobin and oxygen saturation measurement devices. This …
-
Non-Invasive Measurement of Atherosclerosis in relation to cardiovascular risk factors. A study in the general population & Familial Combined Hyperlipidemia.
Contains fulltext : 74941.pdf (Publisher’s version ) (Open Access)
-
A Smartphone-Based Non-Invasive Measurement System for Blood Constituents from Photoplethysmography (PPG) and Fingertip Videos Illuminated with the Near-Infrared LEDs
… blood samples in laboratories. A non-invasive, cheap, point-of-care, and accurate test is needed everywhere. We started with Hgb measurement, and after an extensive literature survey, we came up with a non-invasive solution with 10-second Smartphone videos of the index fingertips using …
-
Non-invasive measurement of stress and pain in cattle using infrared thermography : a thesis submitted in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Animal Science at Massey University, Palmerston North, New Zealand
… the use of infrared thermography (IRT) to non-invasively measure stress and/or pain in cattle. The main approach was to measure changes in heat emitted from superficial capillaries around the eye (referred to as eye temperature) in response to various aversive husbandry procedures used …
-
Experimental Measurement of Blood Pressure in 3-D Printed Human Vessels
A pulsatile flow loop can be suitable for measurement of in vitro blood pressure. The pressure data collected from such a system can be used for evaluating stenosis in human arteries, a condition in which the arterial lumen size is reduced. The objective of this work is to develop an experimental …
Page 1 of 8