Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 9 of 9 for “"inversion-recovery method"”.
-
Development of Dual-Scan Nuclear Magnetic Resonance (NMR) Pulse Programs for Spin-Lattice Relaxation Measurements
This research develops and refines the Split Inversion Pulse and Recovery (SIP R) methodology for spin-lattice relaxation (T₁) measurements in NMR spectroscopy. SIP R introduces a two-scan difference technique using a split inversion pulse sequence, where the 180° pulse is split into two 90° pulses …
-
A Study of Conformation in Disubstituted Cyclohexanes
… determined for the methy!cyclohexanol isomers by Inversion Recovery Method and the results were compared with the Freeman-Hill Method. 13C or : 1H T1 values were used to give an estimate of the strength of intermolecular hydrogen bonding in the methylcyclohexanols.<br/><br/>The axial and …
-
Spatially localized nuclear magnetic resonance
… and experimental implementation of a new method incorporating Nuclear Magnetic Resonance (NMR) methodology, and which enables a volume to be accurately defined and non-invasively interrogated within a larger object, by a sequence of radiofrequency (RF) and linear magnetic field gradient …
-
Lanthanide Functionalised gold nanoparticles as MRI contrast agents
… loaded gold nanoparticles were studied using inversion recovery method and compared with commercially available MRI contrast agents (i.e. Gd-DTPA). The Gd-loaded AuNPs showed only a moderate increase in their relaxivity as compared to the Gd-DTPA complex. The factors limiting the relaxivity of …
-
Quantitative NMR imaging and its applications in vivo
… paramagnetic species were determined using the inversion-recovery method. Intensity was measured directly from images as a function of tau and T₁ obtained from a three parameter exponential fit of the data. The effects of varying imaging conditions on the values of T₁ obtained, were also …
-
⁵¹V, ¹³C and ¹H FT-NMR Studies on Vanadium (V) Species in Aqueous Solutions
… relaxation times (ᴛ₁) are measured using the inversion recovery method for several vanadium (V) species present in solution in the pH range 14 to 1.0. At pH = 14, VO₄³⁻ is the only species present; ⁵¹V ᴛ₁ value for this species is 340 msec, while at pH 1.0 - where only VO₂(H₂O)₄⁺ is present - …
-
Design of portable CMOS NMR system
… To solve this problem, the phase detection method by capturing the phase alignment of two clocks is proposed. The phase detector circuit triggers the on-chip timer that controls the NMR operation. This way, the output phase can remain constant. Second, the slow settling of the receiver …
-
Měření relaxačních konstant technikami MR
… Relaxační časy byly měřeny metodami Inversion Recovery (IR), Hahn Echo (HE) a metodou pološířky.
-
Způsoby váhovaní primárního parametru signálu magnetické rezonance
Cílem této práce je seznámení se základním principem magnetické rezonance a základními měřicími metodami používanými v MR. Dále je zde popsáno, jak nastavovat parametry pulsní sekvence jednotlivých měřících metod, abychom získali obraz váhovaný relaxací T1, relaxací T2, difúzí a případně protonovou …