Showing 1 to 20 of 53 for “"inverted microscope"”.
-
Measuring Diffusion and Quenching in Microchannels
… was visualised under epi-illumination using an inverted microscope. Analyte diffusion occurred across the channel width, and its concentration profile was extracted and analysed by a custom-written Java plugin within ImageJ to give the diffusion coefficient and quenching constant of various …
-
Characterization of the Desorption Electrospray Ionization Mechanism Using Microscopic Imaging of the Sample Surface
… has led to studies of the DESI mechanism. An inverted microscope has been used to image interactions between the DESI spray and test analytes on a glass surface. Microscopic images recorded with millisecond time resolution have provided important insights into the processes governing analyte …
-
Temporal effects of cell adhesion on the mechanical characteristics of the single chondrocyte
… contact area and cell height, as measured using inverted microscope and confocal imaging, were found to increase and decrease respectively.
-
INVESTIGATING THE POTENTIAL APPLICATIONS OF A RAMAN TWEEZER SYSTEM
… an infrared (λ=1064 nm) laser directed into an inverted microscope with NA=1.4 oil immersion 100x objective lens that strongly focuses the laser light into a sample to function as a single-beam gradient force trap. The long term goal of this research program is to develop a single molecule Raman …
-
Design and implementation of full field-optical coherence tomography on an Olympus IX73 microscope
… designed to fit inside an Olympus IX73 inverted microscope. We describe the design, components, and implementation of this novel optical module in detail. The resulting FF-OCT setup (microscope and OCT optical module) can be used as either a Time-Domain system or a Fourier-Domain …
-
A development of the motile sperm sorting microfluidic devices
… microfluidic system are observed using an inverted microscope and recorded by a digital camera. Experiments on fluid flow and on the movement of small particles including cells are conducted. These experiments lead to the development of a Motile sperm Sorting Microfludic System (MSMS).
-
Analysis of Trace Amounts of Adulterants Found in Powders/Supplements Utilizing Direct Inject, Nanomanipulation, and Mass Spectrometry
… be determined. Both the AZ-100 and the TE2000 inverted microscope were used for visual characterizations, image collection and to help guide the extraction. Direct analyte-probed nanoextraction (DAPNe) technique and nanospray ionization mass spectrometry (NSI-MS) was the technique used for …
-
Microfluidic device for rapid detection of fibrinolysis of blood clots
… in the microfluidic device were observed in an inverted microscope to confirm the clot formation. In the study, the dimensions of the microfluidic devices and the sensing electrodes were optimized to improve the sensitivity and to ensure electrical contact between the electrodes and analyte. An …
-
Characterization of a Spiral Microfluidic Focusing Device for Continuous Single Cell Impedance-Based Cytometry Applications
… devices. Particles were observed through an inverted microscope via fluorescent illumination and photographed with a high-resolution digital SLR camera. Quantification of focusing effectiveness and separation distances versus varying flow rates and volume fractions was performed in MATLAB. …
-
Exploring Electric Field-Induced Changes in Astrocyte Behavior
… were recorded every three minutes with an inverted microscope equipped with DIC optics and a stage incubator. Electric fields were found to induce astrocyte responses similar to those observed during periods of neurodevelopment and regeneration. Changes in astrocyte movement, proliferation, …
-
Applications of Nanomanipulation Coupled to Nanospray Mass Spectrometry in Trace Fiber Analysis and Cellular Lipid Analysis.
… The nanomanipulator is mounted to an inverted microscope and consists of 4 nano-positioners; these nano-positioners hold end-effectors and other tools used for manipulation. This original coupling has been used to enhance the current abilities of cellular probing and trace fiber …
-
A Low-Cost Impedance-Based Detection System for Immune-Mediated Cytotoxicity Targeting Tumor Cells
… sensor was maintained within the incubator of an inverted microscope to provide optimal environmental conditions. To test this system, we conducted experiments using two types of immune cells (NK and γδT cells) against SKOV3 ovarian cancer cell line at varying ratios (1:1 and 10:1) and A549 lung …
-
Novel Device to Quantify the Mechanical Properties of Electrospun Nanofibers
… electrospun fibers within the focal plane of an inverted microscope. To limit the complications arising from the inherent random orientation of electrospun fibers, a method of manually depositing parallel electrospun poly(epsilon-caprolactone) (PCL) fibers was developed in this research. The …
-
Transport of Ultra-Fine Particles in Suspension through Structured Porous Media
… The setup consisted of the test cell, an inverted microscope, a high speed camera, a data processor, a precise actuating syringe pump, and spherical silica particles (0.2, 0.5 and 1.5 µm diameter) that encapsulated a fluorescent dye. The particle trajectories deviated from the streamlines …
-
Development of a TIRF Microscope for Single Molecule Binding Studies
… total internal reflection fluorescence microscope (TIRFM) is necessary to study the crucial interaction between PCNA and CAF-1 in replication-coupled nucleosome assembly to contribute to epigenetic inheritance. The microscope measures fluorescence following total internal reflection …
-
Acanthamoeba castellanii induces the in vitro cytotoxicity and cytokines release in human corneal epithelial cells
… The morphological changes of HCECs using an inverted microscope showed that HCECs changed into round shape, when cysts were co-cultured rather than only HCECs cultured. For cytotoxicity assay, high cytotoxicity against HCECs was observed in co-culture system with cysts. A. castellanii induced …
-
Functional study of Gap Junctional Intercellular Communication in Human Keratinocyte Cell Line
… the HaCaT cells and observed by the fluorescence inverted microscope. Captured images were analysed with image software and as a result, acetic acid, hydrogen peroxide, dexamethasone have down-regulated and epicatechin have up-regulated the GJIC function showing statistically significant …
-
A Framework to Understand the Biocompatibility and Motility of E. coli in a Synthetic Yield-Stress Fluid
… a framework for capturing their movement with an inverted microscope. These methods were then used to capture the movement of motile E. coli in Newtonian solutions of Polyethylene Glycol (PEG), and their motility parameters were calculated using DDM. Similarly, preliminary data on the motility of …
-
APPLICATION OF TRACK ETCHED GLASS MEMBRANES FOR SUBMICRON FABRICATION, LITHOGRAPHY AND ERROR RECTIFICATION
… This entire deposition system is housed on an inverted microscope to optically track and register the area of deposition so that if required it can be erased and rectified by agarose hydrogel erasers and PDMS pens. POSE can deposit, erase and rectify patterns with submicron resolution. Apart …
-
Induced Polarization Imaging and Other Topics Associated with the Solid Immersion Lens
… the SIL system. An experimental SIL near-field microscope setup is developed and demonstrated. A compact mechanical package is developed for a standard microscope that implements a SIL on a retractable bimorph swing arm. With the compact package mounted on an inverted microscope, far-field and …
Page 1 of 3