Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 73 for “"ion chamber"”.

  1. Design and optimization of 6li neutron-capture pulse mode ion chamber

    … inexpensive 6Li neutron-capture pulse-mode ion chamber (LiPMIC) for neutron detection that overcomes the fill-gas contamination stemming from outgas of detector components. This research also provides a demonstration of performance of LiPMICs. Simulations performed with GARFIELD, a …

    tamu Repository record for Design and optimization of 6li neutron-capture pulse mode ion chamber (opens in a new tab)

  2. Examination of Ionization in Cesium Diode Pumped Alkali Lasers with an Ion Chamber Diagnostic

    … leading candidates for future high power applications, with many potential utilities for the military, aerospace, communications, and scientific diagnostics. A critical step in their development is measurement and understanding of unwanted ionization processes that occur inside the laser, which …

    unm Repository record for Examination of Ionization in Cesium Diode Pumped Alkali Lasers with an Ion Chamber Diagnostic (opens in a new tab)

  3. Dose verification of a stereotactic IMRT treatment planning system

    In this project, ion chamber measurement and film dosimetry were used to verify dose distributions for a new stereotactic IMRT (Intensity Modulated Radiation Therapy) treatment planning system. This technique combines the principles of stereotactic radiosurgery and IMRT to significantly increase …

    ubc Repository record for Dose verification of a stereotactic IMRT treatment planning system (opens in a new tab) Download PDF for Dose verification of a stereotactic IMRT treatment planning system (opens in a new tab)

  4. Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode

    Respiratory gating limits the radiation to a specific part of the breathing cycle and reduces the size of the Planning Target Volume (PTV). This thesis describes a novel quality assurance method for amplitude gating of Stereotactic ABlative Ra- diotherapy (SABR) treatments of liver delivered using …

    uvic Repository record for Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode (opens in a new tab)

  5. Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61

    … an in-water measurement which is based on ionization chambers calibrated in air in terms of air kerma. The variation of the overall correction factor (PQ;cham) and its components (known as corrections for the change in the chamber response due to the change in the spectrum distribution in …

    carleton Repository record for Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61 (opens in a new tab)

  6. Charged Particle Transport in Magnetic Fields in the EGSnrc Monte Carlo Code System

    The advent of magnetic resonance guided radiation therapy provides a promising technology for dealing with tumour motion and anatomical variations during treatment. These machines possess a variety of beam energies, geometrical configurations, and different magnetic field strengths. Although photon …

    carleton Repository record for Charged Particle Transport in Magnetic Fields in the EGSnrc Monte Carlo Code System (opens in a new tab)

  7. The disintegration of neon by fast neutrons

    … bombarded with 2.68 Mev. neutrons from the reaction H²(dn)He³ . A gridded ion chamber, with 1 litre sensitive volume, filled with neon to 6¼ atmospheres pressure, was used to detect disintegrations. Pulses from the ion chamber were amplified, arid recorded on an 18-channel kicksorter. The …

    ubc Repository record for The disintegration of neon by fast neutrons (opens in a new tab) Download PDF for The disintegration of neon by fast neutrons (opens in a new tab)

  8. Dosimetric properties of a prototype high field parallel MRI-Linac

    … goal of treating a patient. Accurate determination of dose is required to ensure good patient outcomes and minimise the potential of harmful side effects from radiotherapy treatments. For MRI-linacs, the magnetic field can impact both the dose deposition and the ion chamber response, …

    unsw Repository record for Dosimetric properties of a prototype high field parallel MRI-Linac (opens in a new tab)

  9. An Evaluation of The Consistency of Imrt Patient-Specific Qa Techniques

    … the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard …

    uthsc Repository record for An Evaluation of The Consistency of Imrt Patient-Specific Qa Techniques (opens in a new tab)

  10. Optimizing Of Spoiler Thickness For Total Body Irradiation (TBI) Utilizing Tomotherapy Technology

    Delivering total body irradiation (TBI) with a Tomotherapy unit presents a unique challenge: minimizing lung dose while achieving a high skin dose. Acrylic spoilers offer a potential solution by slightly attenuating the incident photon beam, and therefore, reduce the lung dose. The spoilers can …

    gatech Repository record for Optimizing Of Spoiler Thickness For Total Body Irradiation (TBI) Utilizing Tomotherapy Technology (opens in a new tab)

  11. An evaluation of patient-specific IMRT verification failures

    … Island Centre (VIC), the clinical verification of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) …

    uvic Repository record for An evaluation of patient-specific IMRT verification failures (opens in a new tab)

  12. Detectors in Medical Physics Measuring Dose by Detectors

    … the depth dose curve for both energies. In addition the doses were obtained by using three method of detectors suck as the ion chamber, TLDs, and films. Approximately the same results of doses were obtained for all measurement by using different detectors. Therefore, these detectors are reliable …

    south-carolina Repository record for Detectors in Medical Physics Measuring Dose by Detectors (opens in a new tab)

  13. The design, construction, and testing of a reactimeter

    … The reactimeter is comprised of a compensated ion chamber that measures the neutron flux of the reactor and a microcomputer that performs the reactivity calculations. The calculations are based on the six group, point reactor kinetics equations. To simplify the algorithm programming into the …

    vt Repository record for The design, construction, and testing of a reactimeter (opens in a new tab)

  14. Commissioning of an Upgraded Equinox-100 Cobalt-60 Radiation Therapy Unit in the Varian Eclipse Treatment Planning System

    The introduction of Cobalt 60 (Co 60) units in the 1950s established megavoltage radiation therapy worldwide. Unfortunately, advances for the Co 60 radiation treatment units were not heavily pursued over the years and Co 60 units have been steadily replaced by clinical linear accelerators (linacs) …

    queens Repository record for Commissioning of an Upgraded Equinox-100 Cobalt-60 Radiation Therapy Unit in the Varian Eclipse Treatment Planning System (opens in a new tab)

  15. Modification and Implementation of The Rpc Heterogeneous Thorax Phantom For Verification of Proton Therapy Treatment Procedures

    … phantoms that are used to evaluate radiation treatment procedures as part of a comprehensive quality assurance program for institutions participating in clinical trials. It was hypothesized that the existing RPC heterogeneous thorax phantom can be modified to assess lung tumor proton beam …

    uthsc Repository record for Modification and Implementation of The Rpc Heterogeneous Thorax Phantom For Verification of Proton Therapy Treatment Procedures (opens in a new tab)

  16. Development and Commissioning of An Independent Peer Review System For A Small Animal Irradiator

    … small animal irradiators lacks the standardization of clinical radiotherapy practice, yet plays a central translational role in human trial design. The purpose of this work was to improve the dosimetric accuracy and consistency of animal studies by developing an independent peer review system to …

    uthsc Repository record for Development and Commissioning of An Independent Peer Review System For A Small Animal Irradiator (opens in a new tab)

  17. Advanced neutron irradiation system using Texas A&M University Nuclear Science Center Reactor

    A heavily filtered fast neutron irradiation system (FNIS) was developed for a variety of applications, including the study of long-term health effects of fast neutrons by evaluating the biological mechanisms of damage in cultured cells and living animals such as rats or mice. This irradiation …

    tamu Repository record for Advanced neutron irradiation system using Texas A&M University Nuclear Science Center Reactor (opens in a new tab)

Page 1 of 4