Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 160 for “"ion current"”.

  1. Ion current modulation in bio-mimetic channel systems

    Ion channels form information processing in living cells by facilitating electrical signals across and along cellular membranes. Applying the same principles to man-made systems requires synthetic ion channels that can alter their conductance in response to various external manipulations. And the …

    uiuc Repository record for Ion current modulation in bio-mimetic channel systems (opens in a new tab)

  2. Theory of Ion Transport and Ion Current Rectification in Nanofluidic Diodes

    … A comprehensive theory was constructed for ion current rectification (ICR) in nanofluidic systems, written from an engineering and physics perspective. The primary goal of this work was to clarify the fundamental theory of ICR through the interpretation and consideration of various …

    clemson Repository record for Theory of Ion Transport and Ion Current Rectification in Nanofluidic Diodes (opens in a new tab)

  3. Ion Current Analysis And Misfire Prediction During Cold Start In A Compression Ignition Engine

    In future, compression ignition engines are anticipated to continue powering heavy-duty trucks and certain machinery, while passenger vehicles and light-duty vehicles will increasingly be battery powered. However, compression ignition engines face challenges such as combustion instability, …

    wayne-thes Repository record for Ion Current Analysis And Misfire Prediction During Cold Start In A Compression Ignition Engine (opens in a new tab)

  4. Enhancing Knock Detection and Combustion Diagnostics : A Machine Learning Approach with Ion Current Sensors

    … robust and efficient control of internal combustion engines is critical for meeting stringent environmental regulations and reducing greenhouse gas emissions. Natural gas engines, in particular, offer significant potential for cleaner energy but present unique challenges due to variations in fuel …

    lund Repository record for Enhancing Knock Detection and Combustion Diagnostics : A Machine Learning Approach with Ion Current Sensors (opens in a new tab) Download PDF for Enhancing Knock Detection and Combustion Diagnostics : A Machine Learning Approach with Ion Current Sensors (opens in a new tab)

  5. Ion Current Rectification in NanoMicro-Fluidic Interfaces and Pulsed Glow Discharge Time-of-Flight Mass Spectrometric Chemical Speciation

    … disposability, portability, low sample consumption, fast analysis time, and parallel analysis potential for multiple samples in a single device. To improve microfluidic device functionality, integrated systems-nanofluidic/microfluidic interfaces (NMIs) have been fabricated for concentrating …

    wvu Repository record for Ion Current Rectification in NanoMicro-Fluidic Interfaces and Pulsed Glow Discharge Time-of-Flight Mass Spectrometric Chemical Speciation (opens in a new tab)

  6. Studies on the Load Range of an HCCI Engine using In-Cylinder Pressure, Ion Current and Optical Diagnostics

    Internal combustion engines are continuously developed towards decreased hazardous emissions and lower fuel consumption. The homogeneous charge compression ignition (HCCI) engine is a promising concept which combines the best features of the Diesel engine and the spark ignition (SI) engine. The …

    lund Repository record for Studies on the Load Range of an HCCI Engine using In-Cylinder Pressure, Ion Current and Optical Diagnostics (opens in a new tab) Download PDF for Studies on the Load Range of an HCCI Engine using In-Cylinder Pressure, Ion Current and Optical Diagnostics (opens in a new tab)

  7. Ion Current Rectification in Nano/Micro-Fluidic Interfaces and Pulsed Glow Discharge Time-of-Flight Mass Spectrometric Chemical Speciation

    … disposability, portability, low sample consumption, fast analysis time, and parallel analysis potential for multiple samples in a single device. To improve microfluidic device functionality, integrated systems-nanofluidic/microfluidic interfaces (NMIs) have been fabricated for concentrating …

    wvu Repository record for Ion Current Rectification in Nano/Micro-Fluidic Interfaces and Pulsed Glow Discharge Time-of-Flight Mass Spectrometric Chemical Speciation (opens in a new tab)

  8. Spectroscopic investigations of detachment on TCV: Investigating the role of atomic physics on the ion current roll-over and the dynamics of detachment in TCV

    … is required to reduce heat loading and erosion in a magnetic fusion reactor. In this thesis the physics leading to the decrease of the divertor ion current It, or ‘roll-over’, is experimentally explored on the TCV tokamak through characterization of the location, magnitude and role of the …

    whiterose Download PDF for Spectroscopic investigations of detachment on TCV: Investigating the role of atomic physics on the ion current roll-over and the dynamics of detachment in TCV (opens in a new tab)

  9. Ionization in diesel combustion: Mechanism, new instrumentation and engine applications

    … particulate smoke (Soot). To reduce these emissions, close loop engine control strategies are required. Therefore, there is a need for an in-cylinder combustion sensor. The ion current sensor has been used for combustion sensing in gasoline engines for which ionization mechanisms have been …

    wayne-thes Repository record for Ionization in diesel combustion: Mechanism, new instrumentation and engine applications (opens in a new tab)

  10. Combustion, Ionization And Sporadic Pre-Ignition In A Turbocharged Gasoline Direct Injection Engine.

    This research is focused on the use of ionization of combustion products in hydrocarbons-air flames to gain a better understanding of the combustion process in turbocharged gasoline direct injection engines. A GM 2.0 L Ecotec GDI-T engine is used in this investigation. The ion current is measured …

    wayne-thes Repository record for Combustion, Ionization And Sporadic Pre-Ignition In A Turbocharged Gasoline Direct Injection Engine. (opens in a new tab)

  11. The precise measurement of mass spectrometer ion currents

    … involved in making precise mass spectrometer ion current measurements. A survey of the literature of the past decade shows that until the new type of system discussed in Chapter 3 was presented by R.D. Russell and F. Kollar, remarkably few developments were made in improving the precision of …

    ubc Repository record for The precise measurement of mass spectrometer ion currents (opens in a new tab) Download PDF for The precise measurement of mass spectrometer ion currents (opens in a new tab)

  12. Ionization In Diesel Combustion For On-Board Diagnostics And Engine Control

    … about engine-out NOx and particulate matter emissions. To meet the current emission standards, advanced diesel engines are fitted with electronically controlled fuel injection systems and sophisticated and expensive after-treatment devices. Further improvements are still needed to meet future …

    wayne-thes Repository record for Ionization In Diesel Combustion For On-Board Diagnostics And Engine Control (opens in a new tab)

  13. Rationally Designed DNA Origami Carriers for Quantitative Single Molecule Detection with Nanopipettes

    The ability to detect small concentrations of biomarkers in patient samples is one of the cornerstones of modern healthcare. In general, biosensing approaches employed to address this need are based on measuring signals resulting from the interaction of a large ensemble of molecules with the …

    whiterose Download PDF for Rationally Designed DNA Origami Carriers for Quantitative Single Molecule Detection with Nanopipettes (opens in a new tab)

  14. Flush probe studies of plasma flow over a flat plate

    … continuum plasma and observing the relaxation of the ion current to flush probes mounted in the plate. The time it takes to relax to a new equilibrium ion current equals the flow time along the ion sheath edge from the flat plate's leading edge to the flush probe. A simplified theory was …

    uvic Repository record for Flush probe studies of plasma flow over a flat plate (opens in a new tab)

  15. High current coaxial ion beam/laser beam spectrometer

    The construction and operation of a new apparatus for making spectroscopic investigations of molecular ions is described. In the new ion beam machine, the ion beam and laser beam overlap in a coaxial geometry. The machine has much higher ion current than an apparatus previous used. The laser beam …

    unlv Repository record for High current coaxial ion beam/laser beam spectrometer (opens in a new tab) Download PDF for High current coaxial ion beam/laser beam spectrometer (opens in a new tab)

Page 1 of 8