Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 18 of 18 for “"ion gun"”.
-
Ion gun operations at high altitudes
… at high altitudes. Experiments with the SCATHA ion gun were monitored by charged particle detectors and the electric field experiment. It was found that the electric field experiment could be used to measure satellite potential during ion beam emission in sunlight and eclipse. Unneutralized ion …
-
Investigation of a low energy alkali ion gun.
… by Simpson and Kuyatt for a multistage electron gun has been modified for use with ions. In the work reported here a thermal emitter of Lithium ions using the mineral ß-eucryptite was employed as a source of ions. While the electron gun yielded a space charge limited beam, practical and …
-
Characterization modeling of the flow through ion gun: applications to nitride processing
Includes bibliographical references (pages 157-169).
-
Transmission Electron Microscopic Observation of the Imperfection Structure of As-Grown Rutile Single Crystals Thinned by Ionic Bombardment
Thin sections of rutile have been produced for transmission electron microscopy using ionic bombardment as the last stage or the thinning process. The surface of the specimens were (100), (110), and (001) planes. The orientations are substantiated by selected area diffraction patterns. The optimum …
-
Parallel Plasma Field Directed Sputter Sharpening of Field Emitters
… emitters using a DC glow discharge plasma as the ion source in conjunction with field directed sputter sharpening methodology. With field directed sputter sharpening, a positive voltage bias is applied to the field emitter and impinging ions are repelled away from the apex of the tip to the shank …
-
A study of ion acceleration at rocket altitudes and development and calibration of pitch angle imaging charged particle detectors
… presented. It has been found that four types of ion populations were observed during this flight. During the early portions of the upleg and late portions of the downleg numerical fits of the plasma will be compared with in-situ data to show the Maxwellian behavior and derived plasma parameters. …
-
Experimental and Modeling Studies of Low-Energy Ion Sputtering for Ion Thrusters
… xenon-molybdenum (Xe+-Mo) sputtering yields for ion energies of 100 eV and less. Sputtering yield data at these energies are important for ion thruster design and lifetime prediction. The basic principles of sputtering phenomena are discussed. An overview of various popular types of experimental …
-
ION-INDUCED PROCESSES IN OPTICAL COATINGS (BOMBARDMENT, THIN FILMS).
Nearly all the deficiencies of conventional vacuum evaporated coatings trace to a single physical property of condensed films: low packing density. One way to increase packing density is to bombard the growing film with ions during deposition, called ion-assisted deposition (IAD). The beginning …
-
The Effect of Ion Energy and Substrate Temperature on Deuterium Trapping in Tungsten
… candidate plasma facing material for next generation magnetic fusion devices such as ITER and there are major operational and safety issues associated with hydrogen (tritium) retention in plasma facing components. An ion gun was used to simulate plasmamaterial interactions under various conditions …
-
The Application of Resonance Ionisation Mass Spectrometry to Trace Analysis in Solids
Resonant ionisation mass spectrometry (RIMS) is a laser based technique which can detect gas phase atoms with a very high degree of selectivity and sensitivity. The basic concepts of the technique are detailed. For RIMS to be applied to the detection of trace quantities of elements in solid samples …
-
Experimental and computational investigation of tin interaction with hydrogen gas
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2022-11-15 without embargo terms
-
The Application of Resonance Ionisation Spectroscopy to III-V Semiconductor Surface and Depth Analysis
Resonance Ionisation Spectroscopy (RIS) is a relatively new analytical technique which is gaining increasing significance in the field of quantitative trace analysis. This work is principally concerned with the particular application of Resonance Ionisation Spectroscopy to surface and depth …
-
A Neutral Beam Probe for the Helimak plasma experiment
… plasma of the Helimak. After some fraction of the atoms underwent electron impact ionization, the resulting ion beam followed a path to an energy analyzer where the change of energy was detected along with the total ion current. The measurement of the change of energy implies a change of …
-
LEEDS studies of adsorbate-induced reconstruction of metal surfaces
… the technique of low-energy electron diffraction (LEED), the structures of three systems have been investigated, where small, electronegative atoms chemisorb and induce reconstruction at a metal surface; these surfaces are designated Ni(111)-(2x2)-0,Cu(110)-(2x3)-N, and Pd(100)-(V5x45)R27°-0. …
-
LEED crystallographic studies for chemisorption on the Cu(100) surface
… studies with low-energy electron diffraction (LEED) for the surface structures designated Cu(100)-(2x2)-S, Cu(100)-c(2x2)-N, Cu(100)-(√2x√2)45°-O and Cu(100)-(2x√2x√2)45°-O formed by chemisorption on the (100) surface of copper. In each case the intensity-versus-energy curves (I(E) curves) …
-
Laser Ionisation Spectroscopy of Alkalis: Applications to Resonance Ionisation Mass Spectrometry
Resonance ionisation spectroscopy (RIS) at Glasgow University began as a result of the need to calibrate large gas-filled multiwire proportional counters (MWPCs) currently being built at CERN, specifically the ALEPH time projection chamber. From this work the direction shifted towards the …
-
Metodika stanovení tloušťky odprášených vrstev při využití XPS hloubkového destruktivního profilování
… fotoelektronového spektrometru (XPS) vybaveného iontovým dělem. Výzkum zahrnuje přípravu vzorků oceli v různých korozních prostředích, které jsou pak analyzovány a vyhodnoceny. Dle zjištěných dat je stanovena tloušťka korozních vrstev oceli.