Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"ion neutral collision"”.

  1. Ion Mobility Spectrometry Coupled to Mass Spectrometry for Glycoanalysis: Ion-Neutral Collision Cross Section Calibration and Application to Glycopeptides

    … which when perturbed, may lead to dysfunction and disease. Specifically, protein glycosylation plays several key roles including cell-cell signaling, intermolecular recognition, protein folding, stability, and solubility. Protein glycosylation is non-template driven, and altered …

    nebraska Repository record for Ion Mobility Spectrometry Coupled to Mass Spectrometry for Glycoanalysis: Ion-Neutral Collision Cross Section Calibration and Application to Glycopeptides (opens in a new tab)

  2. High Resolution Ion Mobility Spectrometry with Increased Ion Transmission: Exploring the Analytical Utility of Periodic-Focusing DC Ion Guide Drift Cells

    Drift tube ion mobility spectrometry (IMS) is a powerful, post-ionization separation that yields structural information of ions through an ion-neutral collision cross section. The ion-neutral collision cross section is governed by the collision frequency of the ion with the neutral drift gas. …

    tamu Repository record for High Resolution Ion Mobility Spectrometry with Increased Ion Transmission: Exploring the Analytical Utility of Periodic-Focusing DC Ion Guide Drift Cells (opens in a new tab)

  3. Heating of ions by low-frequency Alfven waves in solar atmosphere

    … for heating the solar atmosphere in regions such as the chromosphere (partially ionized) and the corona (fully ionized) remain quantitatively unknown. This thesis demonstrates that the ions can be heated by Alfven waves with low frequencies in fully and partially ionized low beta …

    gatech Repository record for Heating of ions by low-frequency Alfven waves in solar atmosphere (opens in a new tab)

  4. Gas-phase and Solution-phase Peptide Conformations Studied by Ion Mobility-mass Spectrometry and Molecular Dynamics Simulations

    Ion mobility spectrometry (IMS) separates ions on the basis of ion-neutral collision cross-sections (CCS, [omega]), which are determined by the geometry or conformation of the ions. The size-based IM separation can be extended to distinguish conformers that have different shapes in cases where …

    tamu Repository record for Gas-phase and Solution-phase Peptide Conformations Studied by Ion Mobility-mass Spectrometry and Molecular Dynamics Simulations (opens in a new tab)

  5. Monitorying the Desolvaiton of Ions and Create Candidate Structure for the Ions Detected by Ion Mobility-Mass Spectrometry Study by Molecular Dynamics Simulations

    Electrospray ionization ion mobility mass spectrometry (ESI-IM-MS) has emerged in recent years as a tool to separate heterogeneous conformer populations and determine ion-neutral collision cross sections (CCS). However, IM cannot provide specific structural information such as atomic coordinates …

    tamu Repository record for Monitorying the Desolvaiton of Ions and Create Candidate Structure for the Ions Detected by Ion Mobility-Mass Spectrometry Study by Molecular Dynamics Simulations (opens in a new tab)

  6. DENSITY AND VELOCITY MEASUREMENT OF ARI AND ARII USING LASER INDUCED FLUORESCENCE (LIF) IN A LARGE-SCALE HELICON PLASMA

    … and therefore have significant densities of neutral particles. However, the role of neutrals in the overall plasma dynamics, such as ion flows, remains poorly understood. There are at least two possible mechanisms for neutrals to influence ion flows. One is an FxB drift, where F is the force …

    unm Repository record for DENSITY AND VELOCITY MEASUREMENT OF ARI AND ARII USING LASER INDUCED FLUORESCENCE (LIF) IN A LARGE-SCALE HELICON PLASMA (opens in a new tab)

  7. Microphysics of Ion and Electron Energization in the Topside Ionosphere

    Ionospheric ion and electron energization and field-aligned transport are critical processes of magnetosphere-ionosphere-thermosphere coupling. The Canadian Enhanced Polar Outflow Probe (e-POP) satellite carries particle and field instruments specifically designed to study micro-scale …

    calgary Repository record for Microphysics of Ion and Electron Energization in the Topside Ionosphere (opens in a new tab)

  8. Investigation on Gas-phase Structures of Biomolecules Using Ion Mobility-mass Spectrometry

    IM-MS is a 2-D technique which provides separations based on ion shape (ion-neutral collision cross-section, Ω) and mass (m/z ratio). Ion structures can be deduced from the measured collision cross-section (Ωmeas) by calculating the collision cross-sections (Ωcalc) of candidates generated by …

    tamu Repository record for Investigation on Gas-phase Structures of Biomolecules Using Ion Mobility-mass Spectrometry (opens in a new tab)

  9. Development of a biplanar micro multipole ion trap

    … this thesis a microfabricated biplanar multipole ion trap for experiments under ultra high vacuum conditions is developed. The basic design stems from a well known 22-pole ion trap, fabricated with conventional machining methods. High-order multipole ion traps have the advantage of large field …

    freiburg-diss Repository record for Development of a biplanar micro multipole ion trap (opens in a new tab)

  10. Small-scale fluctuations in D-region ionization due to hydrodynamic turbulence

    The fluctuations at small length scales in V-region ionization caused by atmospheric turbulence are investigated. Consideration is given to the dynamics of the plasma, the statistical theory of turbulent advection, the relaxation to photochemical equilibrium, and the theoretical prediction of …

    uiuc Repository record for Small-scale fluctuations in D-region ionization due to hydrodynamic turbulence (opens in a new tab)

  11. New-Measurement Techniques to Diagnose Charged Dust and Plasma Layers in the Near-Earth Space Environment Using Ground-Based Ionospheric Heating Facilities

    Recently, experimental observations have shown that radar echoes from the irregularity<br />source region associated with mesospheric dusty space plasmas may be modulated by radio wave heating with ground-based ionospheric heating facilities. These experiments show great promise as a diagnostic for …

    vt Repository record for New-Measurement Techniques to Diagnose Charged Dust and Plasma Layers in the Near-Earth Space Environment Using Ground-Based Ionospheric Heating Facilities (opens in a new tab)