Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 151 for “"ionization detector"”.

  1. Calibration of flame ionization detector for chlorinated hydrocarbons

    … for chlorine substituted compounds on FI detector at standard conditions. This is in contrast with previous investigators studies which employed older detector designs. Recent engineering improvement (1970 to present) in FI detector design and geometry with optimized combustion, flow …

    njit Repository record for Calibration of flame ionization detector for chlorinated hydrocarbons (opens in a new tab)

  2. Pulsed helium ionization detector electronics system for gas chromatography

    <p>The helium ionization detector (HID) is one of the most sensitive detectors currently available for gas chromatography. The ionization efficiency is estimated to be as high as 5% as opposed to 0.0005% for the flame ionization detector. Despite its sensitivity and a universal response mechanism, …

    utk-theses Repository record for Pulsed helium ionization detector electronics system for gas chromatography (opens in a new tab)

  3. A Hairpin Resonator Based Flame Ionization Detector for Gas Chromatographs

    A novel hydrocarbon-sensitive detector was investigated to determine if readily achievable sensitivity compares with that of the contemporary flame ionization detector. The targeted application is for use in a gas chromatograph system as a complement to less discriminatory detectors. A series of …

    houston Repository record for A Hairpin Resonator Based Flame Ionization Detector for Gas Chromatographs (opens in a new tab)

  4. Measurement of oxygenated volatile organic compounds using the thermionic ionization detector

    A thermionic ionization detector (TID) consists of a catalytically active, low work function heated source. It responds to molecules with high electron affinity which can extract electrons from the surface of the source to form negative ions. TID has been used as selective detectors for nitrogen …

    njit Repository record for Measurement of oxygenated volatile organic compounds using the thermionic ionization detector (opens in a new tab)

  5. Development and experimental analysis of a micro-flame ionization detector for portable gas chromatographs

    A portable micro-FID has been developed that utilized a diffusion flame encased in a micro-fabricated SOI structure. The micro-flame was fueled by a portable electrolyzer that provided the hydrogen and oxygen flow rates necessary for the device operation. The micro-FID was able to detect organic …

    uiuc Repository record for Development and experimental analysis of a micro-flame ionization detector for portable gas chromatographs (opens in a new tab)

  6. Characteristics of a Novel Alkali Flame Ionization Detector as an Air Sensor for Volatile Organonitrogen Compounds

    … and characterization of a novel alkali flame ionization detector (AFID) for use as an air sensor for organonitrogen compounds without any chromatographic separation. Using a planar channelled quartz design, a simple, lightweight architecture for the portable device is presented, which yields a …

    calgary Repository record for Characteristics of a Novel Alkali Flame Ionization Detector as an Air Sensor for Volatile Organonitrogen Compounds (opens in a new tab)

  7. Characterizing a rapid extraction apparatus for the removal of VOCs from aqueous samples and interfacing it with fast analysis systems such as the aromatic specific laser ionization detector.

    … aqueous samples in less than one minute. Also, a detector that is highly selective for aromatic VOCs will be discussed in detail. Extraction of VOCs from aqueous samples into the gas phase is often the timelimiting step in an analysis. A rapid aqueous sample extraction (RASE) system was developed …

    nodak Repository record for Characterizing a rapid extraction apparatus for the removal of VOCs from aqueous samples and interfacing it with fast analysis systems such as the aromatic specific laser ionization detector. (opens in a new tab)

  8. Measurement of Low Vapor Pressures: A Kinetic Approach

    … tube. The air stream was combusted, and a flame ionization detector was used to measure the mass of CO2 so obtained. Several different flow rates were used at each temperature with each substance.

    portland-state Repository record for Measurement of Low Vapor Pressures: A Kinetic Approach (opens in a new tab)

  9. Thermal desorption of hazardous and toxic organic compounds from soil matrices

    … and a gas chromatogragh equipped with Flame Ionization Detector but no added column other than the soil was used to measure the axial dispersion and the rate of passage of the organic contaminants through various soil matrices. The soil matrices used were Gas Chrom R, organic soil, and …

    njit Repository record for Thermal desorption of hazardous and toxic organic compounds from soil matrices (opens in a new tab)

  10. Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples.

    The Pulsed Discharge Helium Ionization Detector (PDHID) was compared to the Flame Ionization Detector (FID) and the Thermal Conductivity Detector (TCD) for High Speed Gas Chromatography (HSGC). It was shown that the PDHID is as sensitive as the FID but can be less reproducible. Moreover, the PDHID …

    nodak Repository record for Advancements in selenium speciation, fast gas analysis and sample preparation procedures for the chemical analysis of real-world samples. (opens in a new tab)

  11. Effect of inorganic salts on adsorption process

    … of organic pollutants was measured using a Flame Ionization Detector Gas Chromatograph. This study investigated the role of inorganic salts during the sorption process. The results of this study show the improvement of treatment efficiency by the addition of inorganic salts depends on the …

    njit Repository record for Effect of inorganic salts on adsorption process (opens in a new tab)

  12. An explosive vapor generator based on capillary gas chromatography

    … design of the vapor generator replaces a flame ionization detector on the gas chromatograph with an effluent heater system to provide a cloud of explosive vapor while preventing condensation onto the walls of the capillary column. This vapor source has been successfully used to produce vapors of …

    vt Repository record for An explosive vapor generator based on capillary gas chromatography (opens in a new tab)

  13. Catalytic oxidation of chlorinated hydrocarbons over powdered transition metal oxide

    … Gas chromatography with electron capture detector and flame ionization detector was used for quantitative analysis of feed and product streams. Gas chromatography/mass spectrometry and gas chromatography/Fourier transform infrared spectroscopy were used to identify all oxidation products. …

    njit Repository record for Catalytic oxidation of chlorinated hydrocarbons over powdered transition metal oxide (opens in a new tab)

  14. Sorption and desorption of organic compounds by flyash

    … The samples were analyzed using a Flame Ionization Detector Gas Chromatograph. The result of this study demonstrates that isolation/ immobilization of the organic pollutants is technologically feasible by adsorbing the contaminants onto flyash. The residual carbon content of the flyash …

    njit Repository record for Sorption and desorption of organic compounds by flyash (opens in a new tab)

  15. A Kinetic Analysis on Hydrolysis and Hydrothermal Conversion of Cellulose to Dodecane

    … for identification and Gas Chromatography Flame Ionization Detector for quantification. Our findings revealed the formation of a possible dodecane isomer, a known fuel additive. We also examined the role of hydrogen content in conversion and proposed a probable reaction mechanism. Kinetic …

    etsu Repository record for A Kinetic Analysis on Hydrolysis and Hydrothermal Conversion of Cellulose to Dodecane (opens in a new tab) Download PDF for A Kinetic Analysis on Hydrolysis and Hydrothermal Conversion of Cellulose to Dodecane (opens in a new tab)

  16. Characterization of Planar Titanium Platforms for Flame Ionization Detection in Microfluidic Gas Chromatography

    Gas chromatography (GC) with a Flame Ionization Detector (FID) has been widely used for the analysis of volatile organic compounds in various fields. Instrument portability and miniaturization of the FID for micro GC (μGC) applications are of increasing interest. This thesis describes the design …

    calgary Repository record for Characterization of Planar Titanium Platforms for Flame Ionization Detection in Microfluidic Gas Chromatography (opens in a new tab)

  17. Evaluation of a Charge Readout Pad Scheme for Next Enriched Xenon Observatory

    … double beta decay in 136Xenon. Their detector is a liquid xenon filled time-projection-chamber. To ameliorate their measured sensitivity, an improved, scintillation and ionization, detector is required. The work presented here focuses on the development of a new charge readout scheme. …

    carleton Repository record for Evaluation of a Charge Readout Pad Scheme for Next Enriched Xenon Observatory (opens in a new tab)

  18. The terpenes of Virginia pine (<u>Pinus virginiana mill</u>.), with investigations of their attractancy to the southern pine beetle (<u>Dendroctonus frontalis</u> zimm.)

    A gas chromatograph, equipped with a flame ionization detector, was used to qualitatively and quantitatively analyze the monoterpenes of Virginia pine. The instrument was adjusted for optimum performance prior to sample analysis. Two packed columns with stationary phases of different polarity, …

    vt Repository record for The terpenes of Virginia pine (<u>Pinus virginiana mill</u>.), with investigations of their attractancy to the southern pine beetle (<u>Dendroctonus frontalis</u> zimm.) (opens in a new tab)

  19. The Design of Gas Chromatography Ionisation Detectors:A Study of the Electron Capture Detector and the Home Ionisation Detector

    Two gas ionization detectors were studied from an instrument designer's point of view. Experimental results indicate that the electron capture detector is sensitive to carrier gas density and to atmospheric oxygen. The finite conductivity of electrode insulators was also found to play an important …

    aston Download PDF for The Design of Gas Chromatography Ionisation Detectors:A Study of the Electron Capture Detector and the Home Ionisation Detector (opens in a new tab)

  20. Adsorption and kinetics of adsorption by flyash in solution

    … and the samples were analyzed using a Flame Ionization Detector Gas Chromatograph. The potentialities of adsorption on flyash as a method of renovation of water have not been realized fully, because little knowledge is available regarding the effective application of the method for this …

    njit Repository record for Adsorption and kinetics of adsorption by flyash in solution (opens in a new tab)

Page 1 of 8