  1. Study of a novel ionizer configuration for ion thrusters

    … ion engine will require novel concepts for the ionizer with perhaps novel propellants. MEMS, nanotechnology and other technological advances are expected to impact on new designs. Our work shows that the ionization of Argon, which is an alternate fuel to Xenon, can be achieved at low voltages by …

    nps Repository record for Study of a novel ionizer configuration for ion thrusters (opens in a new tab)

  2. Flow study of a novel ionizer configuration with testing apparatus

    … may be the most scalable pending reductions in ionizer size. This work explores a new ionization chamber concept. This thesis reports on the ionization of Argon, an alternative propellant to Xenon, which has been achieved at relatively low voltages with locally designed and manufactured …

    nps Repository record for Flow study of a novel ionizer configuration with testing apparatus (opens in a new tab)

  3. A carbon nanotube pillar array ionizer for miniature ion thruster applications

    … and power. With a substantial reduction in ionizer size, ion thrusters may fulfill all of these requirements. This work explores field ionization with nanotube arrays for a highly-scalable ionizer. Fabrication and testing of carbon nanotube pillar array (CPA) ionizers is undertaken at the …

    nps Repository record for A carbon nanotube pillar array ionizer for miniature ion thruster applications (opens in a new tab)

  4. An efficient ionizer for an atomic beam of helium and a source of doubly charged helium ions.

    Part I An efficient ionizer designed for the ionization of a low intensity molecular beam has been developed. The ionizer will have an efficiency for an argon beam at room temperature and 0.8 amperes plate electron current of greater than 5.3% and for an helium 4 beam at room temperature and 0.8 …

    ubc Repository record for An efficient ionizer for an atomic beam of helium and a source of doubly charged helium ions. (opens in a new tab) Download PDF for An efficient ionizer for an atomic beam of helium and a source of doubly charged helium ions. (opens in a new tab)

  5. Analysis of low-energy neutral hydrogen fluxes using an electron cyclotron resonance-heated discharge

    … based on an ECRH discharge as the neutral flux ionizer. The significant features of the ionizer are its small size and simultaneous excitation of the ECRH mode using a 30 MHz RF driver and relatively small static magnetic fields. Demonstrated is the ability of the ECRH ionizer to ionize …

    uiuc Repository record for Analysis of low-energy neutral hydrogen fluxes using an electron cyclotron resonance-heated discharge (opens in a new tab)

  6. An electrical analysis of an electrostatic precipitator with emphasis on stability

    … Carrier Corporation Light Components Department ionizer with special regard to the stability of the ionizer wires. The basic problem was to study why the ionizer wires vibrated. This unstable condition could lead to arc-over from the wire to the precipitator ground plate and consequently could …

    ut-knoxville Repository record for An electrical analysis of an electrostatic precipitator with emphasis on stability (opens in a new tab)

  7. Measurement of cluster size by retarding potential and time-of- flight methods in an ionized cluster beam deposition system

    … In the retarding potential method, two types of ionizers were used: (1) a wire-cage type ionizer in which a neutral beam passed through the anode wire cage and was showered by electrons from a loop cathode; (2) an electron-gun type ionizer in which an electron beam, rectangular in cross section, …

    njit Repository record for Measurement of cluster size by retarding potential and time-of- flight methods in an ionized cluster beam deposition system (opens in a new tab)

  8. Liquid electrofluiddynamic high voltage generator

    … was examined, and it was found that varying the ionizer supply voltage was the best method for controlling the output current. Two factors, in particular, limited the output of the device, the fluid flow rate and the ionizer design. The problems of fluid contamination and fluid leakage caused the …

    carleton Repository record for Liquid electrofluiddynamic high voltage generator (opens in a new tab)

  9. Design of an ionized cluster beam system for thin film deposition and cluster size measurement

    … by acceleration in the electric potential of the ionizer. This high energy tail observed in the ion spectra consisted of particles with energies up to 200eV.</p><p>Interpretation of the data includes discussion of the energy spread due to electric potential nonuniformities in the ionizer, the …

    njit Repository record for Design of an ionized cluster beam system for thin film deposition and cluster size measurement (opens in a new tab)

  10. Comprehensive modeling approach for air breathing electric propulsion in VLEO

    … ABEP particle collector, a radio-frequency (RF) ionizer and a Hall thruster, (2) develop a comprehensive air collisional cross section reaction mechanism to enable high-fidelity reactive particle simulations, (3) simulate the gas breakdown and plasma discharge within an RF ionizer operating under …

    texas Repository record for Comprehensive modeling approach for air breathing electric propulsion in VLEO (opens in a new tab)

  11. Atomic beam polarized 3He+ ion source

    … spin substates, and the electron bombardment ionizer to produce ³He⁺ ions from the neutral ³He atomic beam. The low velocity beam is required because the nuclear magnetic moment of ³He is of the order of 1000 times smaller than the electronic magnetic moment used to separate beams in …

    ubc Repository record for Atomic beam polarized 3He+ ion source (opens in a new tab) Download PDF for Atomic beam polarized 3He+ ion source (opens in a new tab)

  12. Optimization of a Cesium-Sputter Ion Source for Use in Accelerator Mass Spectrometry

    … along the axis of symmetry away from the ionizer) the target holding the sample or by adjusting the potential difference between the target and ionizer. Experimentally, at routine settings (6 kV target to ionizer potential, 115 ◦C cesium oven temperature, and 35 keV output energy), a …

    ottawa-retro Repository record for Optimization of a Cesium-Sputter Ion Source for Use in Accelerator Mass Spectrometry (opens in a new tab)

  13. Airborne Dissemination of Antibiotic Resistance Genes Near Farms and Effectiveness of Ionization Against Airborne Bacteria in a Classroom

    … ion concentrations between periods with the ionizer turned on and turned off; however, negative, in-room ion concentrations were significantly lower when the ionizer was on with constant fan speed. To account for day-to-day variability in total bacteria concentrations, related to occupancy …

    vt Repository record for Airborne Dissemination of Antibiotic Resistance Genes Near Farms and Effectiveness of Ionization Against Airborne Bacteria in a Classroom (opens in a new tab)

  14. Characterization of particle collection efficiency in an ionizing wet scrubber

    … of a cross-flow packed bed pre-scrubber, an ionizer, and a second cross-flow packed bed scrubber in series. The penetration of the system was studied as a function of particle diameter, gas flowrate, and packing media used in the scrubbers. Studies were conducted at gas flowrates of 500, 900 …

    ut-knoxville Repository record for Characterization of particle collection efficiency in an ionizing wet scrubber (opens in a new tab)

  15. Apparatus for study of ion-thruster propellant ionization

    … ion engine will require novel concepts for the ionizer. MEMS, nanotechnology and other new technologies are expected to impact here. This thesis explores the use of these technologies to enable a new design for ion-thruster propellant ionization. An ideal approach, using expensive fabrication …

    nps Repository record for Apparatus for study of ion-thruster propellant ionization (opens in a new tab)

  16. Cabin air-Quality pollution detection and prevention

    … air-purification technologies such as an air ionizer, a plasma generator, and an ozone generator. Furthermore, this research is split into two sections: The first section focuses on experiments conducted in a real car cabin. The measurements in a laboratory test rig make up the second part. …

    chalmers Repository record for Cabin air-Quality pollution detection and prevention (opens in a new tab)

  17. Charge Distribution Inversion for Supermicrometer Particles via Differential Mobility Analysis and Optical Particle Spectrometry

    … with ions generated in a custom unipolar corona ionizer and become highly charged relative to what is achieved in an equilibrium charge distribution. The particles’ high charge state allows them to traverse the DMA despite their large diameter. The results of this work represent the possibility …

    umn Repository record for Charge Distribution Inversion for Supermicrometer Particles via Differential Mobility Analysis and Optical Particle Spectrometry (opens in a new tab)

  18. HYBRID MEMS FOR TRANSIENT MICROSYSTEMS AND CHIP-SCALE GAS SENSORS

    … array, a pyroelectric lithium niobate (LiNbO3) ionizer is developed. The ionizer uses an integrated resistive heater for producing an average ion current of 9:36 pA during the stochastic ionization process and peak ion current as high as 44:8 nA. All system components operate at < 5V, for …

    cornell Repository record for HYBRID MEMS FOR TRANSIENT MICROSYSTEMS AND CHIP-SCALE GAS SENSORS (opens in a new tab)

  19. Modeling, controlling and optimizing the application of photovoltaic energy on CDI cells

    … the cost of producing water. The Capacitive De-Ionizer (CDI) is a desalination method that directly affects the ions in the solution and attracts them to the electric double layers which release the pure water from the cell. CDIs have been discovered for more than 50 years, but they have …

    ets-quebec Download PDF for Modeling, controlling and optimizing the application of photovoltaic energy on CDI cells (opens in a new tab)

  20. Numerical modeling of air ionization for bioaerosol removal and deactivation of aerosolized virus by air ionization

    … Experiments were conducted using a commercial ionizer in a chamber to validate the model and to quantify the effects of ionization on viral infectivity and virion (viral particles) concentrations. The model predictions of bioaerosol removal were within 22% of the measured values. The results …

    manitoba Repository record for Numerical modeling of air ionization for bioaerosol removal and deactivation of aerosolized virus by air ionization (opens in a new tab)