Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"islanding detection methods"”.

  1. Advanced Islanding Detection Methods for Single Phase Grid Connected PV Inverters

    … including the consequences of failing to detect islanding. Numerous methods for islanding detection have been introduced in literature. They can be categorized into local methods and remote methods. The local methods are categorically divided into passive and active methods. Active methods …

    queens Repository record for Advanced Islanding Detection Methods for Single Phase Grid Connected PV Inverters (opens in a new tab)

  2. Analysis and Design of Phase Lock Loop Based Islanding Detection Methods

    … discusses the grid interface issue of anti-islanding. An electric island occurs when a circuit breaker in the electric power system trips. The distributed resource should disconnect from the electric grid for safety reasons. This thesis will give an overview of the possible methods. Each …

    vt Repository record for Analysis and Design of Phase Lock Loop Based Islanding Detection Methods (opens in a new tab)

  3. Performance assessment of islanding detection methods using the concept of non-detection zones

    … both equipment and personnel safety. Thus, islanding detection methods (IDMs) must be developed and tested. A number of IDMs has been developed to prevent this situation. The goal of this thesis is to investigate a means for comparing the effectiveness of active type IDMs used in an inverter …

    concordia Download PDF for Performance assessment of islanding detection methods using the concept of non-detection zones (opens in a new tab)

  4. Designing Anti-islanding Detection Using the Synchrophasor Vector Processor

    ABSTRACT Designing Anti-Islanding Detection Using the Synchrophasor Vector Processor Ruth Huang The need for distributed generation (DG) has become more and more popular because of the adverse effects of fossil fuels and the fear of running out of fossil fuels. By having DG, there are less …

    calpoly Repository record for Designing Anti-islanding Detection Using the Synchrophasor Vector Processor (opens in a new tab)

  5. Analysis of islanding detection capabilities of multi-inverter systems

    Islanding is one important concern for grid connected distributed resources due to personnel and equipment safety. Inverter-resident islanding detection methods (IDMs) employ locally measured parameters to detect islanding. Passive type IDMs only monitor local variables such as voltage and …

    concordia Download PDF for Analysis of islanding detection capabilities of multi-inverter systems (opens in a new tab)

  6. Transient And Distributed Algorithms To Improve Islanding Detection Capability Of Inverter Based Distributed Generation

    … into distribution networks. The problem of islanding detection and islanding prevention (i.e. anti-islanding) has stimulated a lot of research due to its role in severely compromising the safety of working personnel and resulting in equipment damages. Various Islanding Detection Methods …

    ucf Repository record for Transient And Distributed Algorithms To Improve Islanding Detection Capability Of Inverter Based Distributed Generation (opens in a new tab)

  7. Reliable & selectable islanding detection techniques for low inertia power system

    … concerned about the risk of unintentionalislanding formation.Unfortunately, many existing methods are unable to detect islanding for loads that closelymatch the DG capacity, particularly for higher loading quality factors. Other methods, onthe other hand, reduce the power quality. The …

    strathclyde Repository record for Reliable & selectable islanding detection techniques for low inertia power system (opens in a new tab)

  8. Determination of Requirements for Smooth Operating Mode Transition and Development of a Fast Islanding Detection Technique for Microgrids

    … the islanded microgrid. The importance of fast detection of islanding was therefore highlighted. The IEEE standard 1547.4-2011 recommends application of the existing DG synchronization criteria for microgrid synchronization. The adequacy of these criteria for synchronization of a microgrid with …

    manitoba Repository record for Determination of Requirements for Smooth Operating Mode Transition and Development of a Fast Islanding Detection Technique for Microgrids (opens in a new tab)

  9. Micro grid-islanding detection, autonomous operation, synchronization and re-synchronization and battery based energy storage

    … modeling of a micro-grid with the functions of islanding detection, autonomous operation, synchronization and re-synchronization and energy storage. Topology of local distribution generation is modeled by a grid-tied inverter with LCL filter. Proportional resonant controller is applied to …

    unsw Repository record for Micro grid-islanding detection, autonomous operation, synchronization and re-synchronization and battery based energy storage (opens in a new tab)

  10. Συμβολή στη λειτουργία συστημάτων συνεχούς ρεύματος σε εφαρμογές μικροδικτύων και μητροπολιτικών σιδηροδρομικών δικτύων

    … the operation of microgrids as well as the basic islanding detection methods that appear in literature for the operation of DC networks. In this thesis a novel islanding detection method is developed based on the operation of a controllable load in parallel to the central switch of a DC microgrid. …

    greece Repository record for Συμβολή στη λειτουργία συστημάτων συνεχούς ρεύματος σε εφαρμογές μικροδικτύων και μητροπολιτικών σιδηροδρομικών δικτύων (opens in a new tab)

  11. Operation and Protection of Microgrid: Islanding Detection and Analysis of Load-Generation Balance in Microgrid Using Distribution Synchrophasors

    … some problems still arise, such as unintentional islanding and protection issues. Islanding detection is one of the essential aspects of microgrid operation. Microgrids should be able to operate reliably in both grid-connected and islanded modes. DERs need to be isolated within 2 seconds after an …

    sask Repository record for Operation and Protection of Microgrid: Islanding Detection and Analysis of Load-Generation Balance in Microgrid Using Distribution Synchrophasors (opens in a new tab)

  12. Διερεύνηση της λειτουργίας αντιστροφέων για τη διασύνδεση διεσπαρμένων μονάδων παραγωγής με το δίκτυο χαμηλής τάσης

    … is to thoroughly investigate the anti-islanding capabilities of grid-connected inverters under the high penetration of distributed energy sources (DES) in low-voltage grids.Grid-connected distributed energy sources have been intensively developed over the last decade, increasing their …

    greece Repository record for Διερεύνηση της λειτουργίας αντιστροφέων για τη διασύνδεση διεσπαρμένων μονάδων παραγωγής με το δίκτυο χαμηλής τάσης (opens in a new tab)