  1. A Radio Frequency Quadrupole Instrument for use with Accelerator Mass Spectrometry: Application to Low Kinetic Energy Reactive Isobar Suppression and Gas–phase Anion Reaction Studies

    … quadrupole instrument, currently known as an Isobar Separator for Anions (ISA), has been integrated into an Accelerator Mass Spectrometry (AMS) system to facilitate anion–gas reactions before the tandem accelerator. An AMS Cs+ sputter source provided > 15 keV ions that were decelerated in the …

    toronto-retro Repository record for A Radio Frequency Quadrupole Instrument for use with Accelerator Mass Spectrometry: Application to Low Kinetic Energy Reactive Isobar Suppression and Gas–phase Anion Reaction Studies (opens in a new tab)

  2. Laser Photodetachment of Negative Ions - Fundamental Research and Applications

    … negative ions in the injection stage provides isobar suppression in cases where the contaminating isobar does not form stable negative ions. Several experiments on laser interaction with a beam of mass-selected negative ions are presented. The objective for these studies can be divided into …

    goteborg Repository record for Laser Photodetachment of Negative Ions - Fundamental Research and Applications (opens in a new tab)

  3. Installation and Testing of the Isobar Separator for Anions at the A. E. Lalonde AMS Laboratory Using Chlorine-36 Analysis

    … (AMS) studies of rare isotopes with abundant isobars that form negative ions often require the use of large accelerators to achieve high sensitivity measurements. The Isobar Separator for Anions (ISA) is a radiofrequency quadrupole (RFQ) reaction cell system that provides selective isobar …

    ottawa-retro Repository record for Installation and Testing of the Isobar Separator for Anions at the A. E. Lalonde AMS Laboratory Using Chlorine-36 Analysis (opens in a new tab)

  4. Remodelling a multi-anode ionisation chamber detector for accelerator mass spectrometry of 53Mn

    … to sensitivities above 10^-13 by insufficient suppression of the stable isobar, 53Cr. To expand the applications accessible to 53Mn analysis, a new detector was ommissioned that will improve the available sensitivity. This thesis covers the implementation of the new Flexible Anti-Scatter …

    anu Repository record for Remodelling a multi-anode ionisation chamber detector for accelerator mass spectrometry of 53Mn (opens in a new tab)