Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 60 for “"isocenter"”.
-
An independant verification of linac isocenter
A verification of Linac isocenter that uses a custom built phantom to determine the size uncertainty caused by gantry rotation. This phantom is built and used in a similar manner as Varians IsoCal phantom and can be used on new and old Linacs in an effort to speed up the calculation of isocenter …
-
A new phantom and gradient isocenter estimation for magnetic resonance imaging distortion correction
… phantom, to estimate the location of gradient isocenter of the magnetic field inside 3T MRI scanner for the first time.
-
A new phantom and gradient isocenter estimation for magnetic resonance imaging distortion correction
… phantom, to estimate the location of gradient isocenter of the magnetic field inside 3T MRI scanner for the first time.
-
Effects of Rotational Motion on Dose Coverage in Single Isocenter Multiple Target Stereotactic Radiosurgery
Stereotactic radiosurgery using a single isocenter multiple target technique is being used widely today. However, not much is known about the extent to which rotational patient motion effects dose coverage. This study investigated this issue by first developing a geometric model to predict dose …
-
Αξιολόγηση αβεβαιοτήτων και επίδρασή τους στις κατανομές δόσης σύγχρονων εφαρμογών ακτινοθεραπείας
… More specifically, single isocenter SRS – VMAT technique with multiple non coplanar arcs can efficiently deliver plans of high dose conformity to the target volumes, while ensuring the required radioprotection of the adjacent healthy tissues and overall, the treatment time …
-
The Effect of Shoulder Variation On Imrt and Smartarc For Head and Neck Cancer
… maximum displacement of the shoulder relative to isocenter over the course of treatment. Second, to establish the dosimetric effect of shoulder displacements relative to correct isocenter alignment on the dose delivered to the target and the surrounding structures for head and neck cancer …
-
Design & Delivery of Automated Winston-Lutz Test for Isocentric & Off-Axis Delivery Stability Utilizing Truebeam Developer Mode & Electronic Portal Imaging Device
… Assuring the coincidence between the mechanical isocenter of the Linear Accelerator (LINAC) and its radiation beams isocenter is one of the most important qualities need to be tested, and the Winston Lust (WL) test is the most popular technique to perform this task, especially for the treatment …
-
Ανάπτυξη προηγμένων αλγορίθμων υπολογιστικής γεωμετρίας στην απεικόνιση ενδοεγκεφαλικών όγκων και στη βελτιστοποίηση της στερεοτακτικής ακτινοθεραπείας
… arcs. All arcs have a common center called the isocenter. The volume around the isocenter receives the maximum energy. Visualization of the several design steps is crucial in order to set up and evaluate a posible treatment plan. In the first part of this work, a 3D mathematical model of the …
-
Characterization of Physical and Dosimetric Aspects of SRS HyperArc Treatment Technique
… radiosurgical doses delivered via single isocenter volumetric modulated arcs (VMAT) for multi-lesion brain cancer. Due to the nature of these types of treatments it is imperative that the proper quality assurance is completed to ensure the safety of the patient. Geometric limits were …
-
On the Development of Computational Methods to Help in Performing Medical Physics Tasks Leveragin the Portal Dosimetry Application
… analyze an integrated image and determine the isocenter wobble of the machine. Two methods were developed to calculate the isocenter wobble. A manually detect method and a auto detect method. The average error in calculating the isocenter wobble when using the manually detect method is 0.1 mm. …
-
Occupational radiation dose during the trans-catheter aortic valve replacement procedure
… were expected because of their proximity to the isocenter of the x-ray beam. The perfusionist’s position in the OR, however, is significantly further away from the isocenter than the physicians’ position, suggesting the x-rays scatter unevenly and further away from the isocenter than previously …
-
Implementing an Optical Surface Monitoring System for Left Breast Radiation Therapy
… surface monitoring system can align patients to isocenter and discern displacements with respect to isocenter. I report that our optical surface monitoring systems can localize targets within 1 mm and 0.5o with an average lag time of 180 ms and standard deviation of the mean 2 ms. This lag time …
-
Computational advances for big data analytics and medical decision making
… programming solution techniques, the multiple isocenter selection problem in radiation therapy treatment planning, and the multi-objective treatment planning optimization problem. Chapter 1 advances the computation aspects of the double pivot simplex method by improving its computational …
-
Advancements in Magnetic Resonance Image Guided Radiotherapy
… gantry angle dependent shifts in the imaging isocenter of a commercial 0.35 T MRI-Linac. Additionally, the balanced steady state free precession (bSSFP) sequences used in MRgRT offer excellent signal to noise ratios (SNRs) and temporal resolution, but require high levels of B0 homogeneity, B0 …
-
Development of a Knowledge-based Planning Pipeline for Gamma Knife Radiosurgery
… GK KBP pipeline. 3. Selecting appropriate isocenters using optimization. Isocenter placement has a significant impact on dose conformity and plan quality. To enhance plans generated using the KBP pipeline and reduce the need for manual intervention, the inverse optimization model and …
-
Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery
… especially those that are far from the treatment isocenter, the rotational setup error threshold may need to be as low as or lower than 0.5°.
-
Dose verification of a stereotactic IMRT treatment planning system
… the measured and the calculated dose at the isocenter can be up to 2%. Angular dependence of ion chamber sensitivity and the tissue equivalence of the phantom material were determined to be the main sources of this discrepancy. Radiochromic film was used as the film dosimeter in the project. …
-
Neutron exposure from electrom linear accelerators and a proton accelerator : measurements and simulations
… as field sizes increased, and with distance from isocenter. The neutron production from the MEVION S250 was found to be comparable with other passive scattering systems.
-
Importance of heterogeneity correction for prostate therapy planning as it relates to prostate motion
… by determining the displacement of each isocenter relative to the original radiotherapy planning CT. For Aim 2, CT scans acquired during the course of SBRT were used to prospectively calculate new treatment plans that incorporated prostate displacement from four dogs, with and without HC. …
Page 1 of 3