Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 15 of 15 for “"joint implants"”.
-
VOLUMETRIC WEAR ANALYSIS OF HIP JOINT IMPLANTS BY OPTICAL METHODS
Predložená dizertačná práca sa zaoberá analýzou opotrebenia totálnych bedrových endoprotéz za použitia optických metód. V práci bol predstavený nový prístup hodnotenia objemového úbytku materiálu pomocou 3D optického skeneru. Tento nový prístup je časovo efektívny, poskytuje veľké množstvo …
-
Dynamic friction of UHMWPE angular compliant bearing for joint implants and machinery
The feasibility of a unique design of orthopedic- joint implant is investigated. The work focuses on the dynamic friction characteristics of a new joint. This unique design can be also useful in machinery involving oscillating motion similar to that of the hip joint during walking. An elastomeric …
-
Interaction of adipose-derived stem cells with titania nanotube surfaces
The need for joint replacement will continue to grow and increase significantly in the coming decades due to the aging population. Unfortunately, many joint implants experience failure after 10-15 years requiring revision surgery. With the growing need for more implants and the high cost of medical …
-
CRYOGENIC BURNISHING OF Co-Cr-Mo BIOMEDICAL ALLOY FOR ENHANCED SURFACE INTEGRITY AND IMPROVED WEAR PERFORMANCE
The functional performance of joint implants is largely determined by the surface layer properties in contact. Wear/debris-induced osteolysis and aseptic loosening has been identified as the major cause of failure of metal-on-metal joint implants. A crucial requirement for the long-term stability …
-
Volume Conduction in Sensing for Physiological Measurements
… aimed at tracking the loosening of shoulder joint implants. To this end, the thesis develops an interdisciplinary approach, characterised in two phases: simulated tests, conducted through the CST Studio Suite software, and real-life tests, conducted through measurements of the capacitance …
-
Multi Scale Contact Mechanics of Bio-Mechanical Systems with inclusion of roughness effect- Fractal Analysis
… will be used to examine both types of failure in joint implants in the human body. These include consideration of implants for hip, ankle, spine and knee. In this case rapid and/or fatigue failures will be considered and related to anticipated implant life cycle based on implant recipient's …
-
Wear and Corrosion Resistance Improvement of CoCrMo alloy by Tantalum Based Coatings
Patients with hip joint implants face a serious problem due to the relatively short lifetime of the prosthesis. Medical grade CoCrMo alloy is one of the most common materials used for femoral head fabrication. Unfortunately, the implant fails usually after 15 years of service due to the excessive …
-
Role of Serum Albumin Aggregation in Lubrication and Wear Protection of Shearing Surfaces
Healthy articular joints exhibit remarkable lubrication due in large part to the complex rheological and tribological behavior of the synovial fluid (SF) that lubricates the joints. Current approaches that seek to elucidate such remarkable lubrication usually focus on the roles of high molecular …
-
In vitro models for cartilage engineering using primary cells and biodegradable scaffolds
… still need improvements. Current treatments with joint implants are not long lasting and frequently require revision. Tissue engineering thus may provide different solutions based on tissues repair, contrarily to substitution by joint implants. This thesis comprises the investigation of three in …
-
Dynamics of Aggregation on Sheared Albumin-Fibronectin Thin Film
Articular joints are one of the most robust bearing systems found in the natural world. Healthy joints can withstand over 100 million shearing and compressive cycles without wear. This phenomenal lubrication is due to both the cartilage that forms the bearing surface and the synovial fluid (SF) …
-
CREATION OF BIOACTIVE SURFACES TO MODULATE CELL BEHAVIOR USING SURFACE INITIATED PHOTOINIFERTER-MEDIATED GRAFT PHOTOPOLYMERIZATION
… response from cells, (like osseointegration of joint implants and endothelialization of stents) can yield much better biocompatibility results when combined with passive prevention of protein adsorption. In more complex diseases like spinal cord injury and cardiomyopathy, specific biomolecules …
-
Swimming Is a Safe Exercise for Patients with Total Hip or Knee Arthroplasty - In Vivo Measured Hip and Knee Joint Loads During Swimming
Background: Joint loading is essential for implant stability, joint mobility, and long-term joint function following total hip arthroplasty (THA) and total knee arthroplasty (TKA). Swimming, as an aquatic therapy, is commonly suggested as a post-surgical rehabilitation exercise for both THA and TKA …
-
3D tištěné biomedicínské implantáty nové generace vyztužené 2D nanovrstvami
Tato bakalářská práce se zabývá analýzou tribologických vlastností 3D tištěných kompozit z materiálu CoCrMo vyztužených nanomateriály typu MXene, které mají za cíl ověřit možnosti vylepšení životnosti kloubních náhrad. Cílem je také experimentálně porovnat chování pinů se stávajícími konvenčními …
-
Perspektiva fullerenů pro kloubní implantáty
Ochorenia kĺbovej chrupavky, najmä osteoartróza, predstavujú závažný medicínsky problém postihujúci až štvrtinu dospelej populácie. Zavedenie lokálnych kĺbových implantátov ako menej invazívnej alternatívy k totálnym náhradám prináša novú kontaktnú oblasť medzi kovom a natívnou chrupavkou, kde …
-
Κατεργασιμότητα λίαν υψηλής ακρίβειας βιολογικών εμφυτευμάτων τεχνητού ισχίου
… and research of the manufacturing of hip joint implant and also tools for their construction, through precision and ultra precision manufacturing and specifically high speed machining. The methodology presents the way that the femoral heads are manufactured, not only for metallic, but also …