Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 19 of 19 for “"joint reaction force"”.
-
Theoretical prediction of joint reaction force in a dynamic general 3-d pendulum tree model for human or animal motion
… coordinates are applied to predict dynamic joint reaction forces in an idealized flexible model of a branched 3-D pendulum tree system. The number of segments and joints on the tree are adjustable as is the branching tree pattern. The segments that comprise the tree are assumed to be one- …
-
Joint Reaction Force and Contributions of Surrounding Muscles to Knee Joint Load during Stair Ascent in Total Knee Replacement Patients and Healthy Individuals
… end stage knee osteoarthritis (OA) of the knee joint. Unfortunately, difficulty with stair climbing has been seen to exist, prolonging the challenges of TKR patents. Complete understanding of loading at the knee is of great interest in order to aid patient populations, implant manufacturers, …
-
Lumbar spine kinematics and kinetics during heavy barbell squat and deadlift variations
… flexion, L4-L5 and L5-S1 moments, and L5-S1 joint reaction force. Methods: Data were collected and reported on 17 healthy competitive strength athletes (male = 12, female = 5, age = 26.5 ± 4.7 years, height = 176.1 ± 4.6 cm, body mass = 97.7 ± 22.3 kg). Participants completed three single …
-
Dynamic Model of Sailors Descending A Navy Ship Ladder
… knee pain, it was hypothesized that the internal joint reaction forces during the sailor's descent of a ship ladder would be greater than internal joint reaction forces of gait and stair climbing. Dimensions of a commonly used Navy ship ladder were collected and a replica was constructed. The …
-
Understanding the mechanical environment of the hip
The hip functions as a ball and socket joint, with cartilage layers that cover the joint surfaces on both sides protecting it from impacts and permitting smooth movements. When the cartilage is impaired by mechanical, infectious or inflammatory causes, the joint might eventually wear down - a …
-
Computational Investigation of the Biomechanics of Babywearing in Regards to Developmental Dysplasia of the Hip
… either loose or otherwise unstable. DDH causes a joint instability where the femoral head is not properly situated inside the acetabulum. Etiology of the condition is in part congenital and developmental, with a difference of DDH prevalence between ethnicities. Incidence of DDH is also in some …
-
Patient-Specific Musculoskeletal Modeling of Total Shoulder Arthroplasty
… debilitating pathologies of the glenohumeral joint such as osteoarthritis, humeral head fracture, and advancing rotator cuff tears. TSA replaces the articulation between the humeral head and the glenoid fossa, with the goals of relieving pain and restoring function. Two types of total shoulder …
-
Trabecular Bone Pattern and Mechanical Load in the Juvenile Knee Joint
… direction and distribution of mechanical force associated with different activities. In the juvenile, several key developmental milestones including weaning, crawling, sitting and the development of a bipedal stance around 1 year of age all have a bearing on the forces passing through the …
-
Population-based Modelling in Clinical Musculoskeletal Biomechanics
… from the IMU was linearly correlated to the knee joint reaction force on a patient-specific level. This wearable technology can assist clinicians identify and monitor high risk patients. The outcomes of the three thesis studies demonstrate the power and applicability of population-based machine …
-
Specimen-specific, three-dimensional knee joint mechanics: normal and reconstructed
… total knee replacement to evaluate ligament and joint function for leg extension. The ligament origins and insertions and articular geometry were obtained from MRI and CT data obtained for each specific cadaver. Twelve elastic elements described the geometry and mechanical properties of the …
-
The Implications of Childhood Obesity on the Musculoskeletal and Locomotor Systems: Biomechanical Analyses and Exercise Intervention
… simulation to quantify compressive tibiofemoral force and individual muscle function. These results suggested that the excess body mass plays a dominant role in a larger joint load and greater energy cost in obese children. The obese children preferred to walk at a speed that has minimal energy …
-
A three-dimensional finite element stress analysis of interface conditions in porous coated hip prosthesis
… the normal walking cycle are analysed. The hip joint reaction force, abductor muscle force and adductor muscle force are applied to the collar of stem and the greater and lesser trochanters.</p><p>The resulting stress distributions indicate that for the fully porous coated inhomogeneous model, …
-
Effects of walking speed on knee joint loading estimated via musculoskeletal modeling
… injuries, particularly at the knee joint, are not uncommon in individuals who walk for exercise. Surprisingly, there is scant data regarding how walking conditions (e.g. speed, grade, surface) affect loads (i.e. contact forces) across lower extremity joints. Studies to date have used …
-
Validation of Markerless Motion Capture for the Assessment of Soldier Movement Patterns Under Varying Body-Borne Loads
… conditions. The aim was to estimate lower body joint kinematics, gastrocnemius lateralis and medialis muscle activation patterns, and lower body joint reaction forces from the two motion capture systems. Data were collected on 16 participants for three repetitions of both walking and running …
-
Effect of Patellar Component Thickness on Patellar Kinematics and Patellofemoral Joint Function Following Total Knee Replacement
… including excessive quadriceps tendon force, patellofemoral joint reaction force, and joint pain in TKR patients during knee joint motion. The objective of the current study was to evaluate the effect of varying patellar component thickness on patellar kinematics and patellofemoral …
-
Assessment of Bore-Cone Taper Junctions in Explanted Modular Total Hip Replacements
… arm at the bore-cone modular junction since the joint reaction force at the hip passes through the center of the femoral head. There are concerns that variations in this head-neck moment arm and other neck cone geometries can negatively impact the stability and surface of the modular bore-cone …
-
Predicting co-contraction with an open source musculoskeletal shoulder model during dynamic and static tasks
The shoulder is one of the most complex joints in the body. It has a large range of motion and has active, as well as passive, components to its stabilization. Many injuries occur every year due to overexertion and strain on the shoulder. Musculoskeletal models can be used as a proactive ergonomics …
-
Evidence of biomechanical functional symmetry in the presence of lower extremity structural asymmetry during running
… have made the pragmatic decision to record force and cinematographical data from only one side of the body and assume symmetry between the left and right sides. This study was devised to address two topics related to the issue of assumed biomechanical symmetry in the study of human gait …
-
The Development and Implementation of a Computational Framework to Simulate Patellofemoral Joint Mechanics
… 25% of adults and is associated with altered joint mechanics. Patellofemoral joint (PFJ) models vary widely in complexity, with no established gold standard. Musculoskeletal models efficiently estimate joint loading but do not capture tissue-level mechanics, whereas finite element (FE) models …