Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 102 for “"joists"”.
-
Optimization of prefabricated joists
… the performance of precast prestressed concrete joists used for floor or roof members. The main objective of this study was to create a joist with web openings. The benefits of web openings are two-fold. First, a reduction of the double tee weight itself is achieved. Second, the web openings are …
-
Web strength of rolled steel joists
… with the behaviour of thin webbed rolled steel joists or universal beams when they are subjected to concentrated loads applied to the flanges. The prime concern is the effect of high direct stresses causing web failure in a small region of the beam. The review shows that although many tests have …
-
Standoff Screws Used In Composite Joists
… as a mechanical shear connector in composite joists. Standoff screws are being investigated as an alternative to welded shear studs in short span composite joists. The data and results obtained from 106 pushout tests performed on the Elco Grade 8 standoff screw are presented. The test …
-
Evaluation of long span composite joists
… of longspan composite open-web steel joists are studied. Eight full scale single span composite joists were tested to failure to evaluate their performance in both the elastic and inelastic ranges. The test specimens' spans, depths, slab depth, and amount of shear connection was …
-
Two-Way Steel Floor System Using Open-Web Joists
… feasibility of interlocking open-web steel joists to form a panelized two-way steel floor system. This thesis includes a detailed discussion of the fabrication of the proposed floor system. A complete description of a proposed construction sequence is also presented. Finally, the structural …
-
Strength Calculation Model for Standoff Screws in Composite Joists
The objective of the research reported herein is to present a comprehensive evaluation of all available experimental data from push-out tests utilizing the ELCO Grade 8 standoff screws. The goal is to develop a strength prediction equation and determine reliability parameters compatible with the …
-
Further Investigation of Standoff Screws Used in Composite Joists
… as a mechanical shear connector in composite joists. Standoff screws are being investigated as viable an alternative to welded shear studs in short span composite joists. The data and results obtained from 59 pushout tests performed on the 5/16 in. diameter Elco Grade 8 standoff screw are …
-
Standoff screws functioning as mechanical shear connectors in composite joists
The results of sixty-five double-sided pushout tests utilizing the Elco grade 8, 5/16 in. diameter, standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate …
-
Reinforcement Schemes for Cold-Formed Steel Joists Having Web Openings
… conducted. Two types of sections (lipped channel joists with h/t ratio 180 and 118) were tested in flexure and one type of section (lipped channel joists with h/t ratio 180) was tested in shear. The study also included a finite element based numerical investigation, consisting of parametric …
-
A study of semi-rigid connections between longspan joists and columns
… type of semi-rigid connection between longspan joists and columns. It is also an attempt to establish a correct technique for testing full size longspan joists and column connections. Although not commonly utilized in industry, in which longspan joists most frequently are used as …
-
DIAGONAL ERECTION BRIDGING FOR OPEN WEB STEEL JOISTS WITH FLUSH FRAME CONNECTIONS
<p>Open web steel joists are highly slender structural members that are susceptible to lateral-torsional buckling before bracing is installed. The stability of joists needs to be properly assessed to ensure safety and efficiency during erection. Current practice for joists is based on a strength …
-
Strength of welded headed studs in ribbed metal deck on composite joists
Standards for stud strength in composite joists are presently not available. Existing standards for composite design are targeted for composite beam design while design of a composite joist requires more emphasis on stud strength to fully develop the joist bottom chord. Stud placement in the deck …
-
Evaluation of deck fasteners functioning as shear connectors for composite steel joists
… as shear connectors for composite open web steel joists is studied. Results of thirty-six push-off tests are evaluated in terms of strength and behavior. Six types of deck fasteners are considered. They are: 1. #12-24 Teks/5 self-drilling, self-tapping screws. 2. 1/4-14 Teks/3 with a 1 1/4 in. …
-
Finite Element Analysis of Unbraced Structural Wood I-Joists Under Construction Loads
… rotational response of unbraced wood composite I-joists to worker loads. All experimentation and modeling was conducted on simply supported I-joists varying from 11-7/8 inches to 14 inches in depth and 20 feet to 24 feet in length. I-joists were subjected to static and dynamic loads. The …
-
Limit state design of timber I-joists with web openings and flange notches
… to other major construction materials. I-joists are engineered timber beams widely used in the building industry as main structural components. They have gained popularity over conventional sawn lumber beams, thanks to their effectiveness and convenience of use. These beams are mainly …
-
Lateral Movement of Unbraced Wood Composite I-Joists Exposed to Dynamic Walking Loads
… walking loads. Three 16 in. deep GPI® 65 I-joists were simply supported and laid parallel to each other, while the bracing was attached to the top flange. Five different brace stiffnesses were used: zero stiffness (control), 1.2 lb/in., 8.5 lb/in., 14.0 lb/in. and infinitely stiff. Two …
-
The effects of cutouts in joists on the vibrational response of wood floors
This thesis presents the effects of cutouts in joists on the dynamic performance of wood floors. Ten floors and four-floor joist types were used to evaluate the vibrational response of wood floors with and without cutouts in the joists. Each floor was also subjected to different boundary conditions …
-
Ultimate strength analysis of partially composite and fully composite open-web steel joists
The behavior of composite steel joists with various degrees of shear connection is investigated. The results of eight full-size composite joist tests, conducted as a portion of the study, are presented. Joist spans range from 24 ft. to 30 ft. and depths from 8 in. to 18 in. Six types of mechanical …
-
Lateral-Torsional Buckling Instability Caused by Individuals Walking on Wood Composite I-Joists
… unfinished structures. Workers walking on wood I-joists on roofs and floors are prone to fall hazards. Wood I-joists have been replacing dimension lumber for many floor systems and a substantial number of roof systems in light-frame construction. Wood I-joists are designed to resist axial stresses …
-
Elastic-plastic finite element modeling of long span composite joists with incomplete interaction
… of seven long span composite open-web steel joists. These analyses account for the incomplete interaction between the concrete slab and the steel joist by modeling the nonlinear behavior of the steel shear connectors. Experimental tests on long span composite open-web steel joists were …
Page 1 of 6