Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 77 for “"kips"”
-
Assessing the suitability of CMMN language for knowledge-intensive processes
… following its release, its applicability to KiPs is still unexplored, with existing research works to be limited to theoretical findings. The aim of this research is to assess the suitability of CMMN for KiPs from the perspective of modelers, while taking into consideration the nature of …
-
Effectiveness of Compacted Fill and Rammed Aggregate Piers for Increasing Lateral Resistance of Pile Foundations
… the pile foundation increased by 5 percent or14 kips due to compacted fill placement against the face of the pile cap. The passive force acting only on the pile cap decreased from 54 kips in the virgin case to 30 kips after installation of the compacted fill, a decrease of about 45 percent. The …
-
Dynamic stiffness and damping of single piles in loess
… <p>Dynamic stiffnesses ranged from 63 kips/inch at the smallest initial deflection to 13 kips/inch at the largest for one pile. For the other pile, the largest stiffness was 45 kips/inch and the smallest was 31 kips/inch. The smaller dynamic stiffness values determined for the first …
-
Experimental Determination Of The Pull-Out Strength Of Cast-In Lifting Inserts In Precast Hollow-Core Plank
… in an average measured tensile capacity of 13.8 kips with a standard deviation of 1.85 kips. Our predictive model gave us a capacity of 12.33 kips which is within one standard deviation from the average measured capacity. A factor of safety of 2.2 was also calculated and developed. When we apply …
-
Strengthening reinforced concrete bridge T-beams with CFRP sheets plus bi-directional GFRP U-wraps
… tested as a control beam failing at around 64.58 kips. The second beam was strengthened with one layer of CFRP, spanning 15 feet and starting 3 inches from each support. This beam failed 60.13 kips. The third beam was strengthened the same way as the second beam, but in addition to the CFRP sheet …
-
Strengthening rectangular beams with NSM steel bars and externally bonded GFRP
… tested as a control beam failing at about 12.24 kips. The second beam is strengthened using two #5 steel NSM bars and 1 layer of GFRP, both extending to the support. This beam failed at 31.6 kips. The third beam is strengthened with the same system used for the second beam. However, the NSM steel …
-
Computational Simulation of Kinetic Projectile Impact for Injury Assessment
… of high-caliber kinetic impact projectiles (KIPs) to the thoracic region. While KIPs are widely used for crowd control, their classification as non-lethal has been increasingly challenged due to documented fatalities resulting from impacts to the thoracic region. This research utilizes the …
-
Evaluation of alternative resistance mechanisms for progressive collapse
… reinforcement frame reached a load of 2.34 kips under compressive arch action and 8.19 kips under catenary tension. The continuous reinforcement frame reached a load of 5.81 kips under the flexural action and 8.30 kips under catenary tension. The frame with the infill wall did not perform …
-
Combined NSM steel bars and externally bonded GFRP in strengthening T beams
… loading until failure. The load rate was 1 kips/min. The first specimen is tested as a control beam failing at about 15 kips. The second specimen is strengthened using two #5 steel NSM bars and 1 layer of GFRP, both extending to the support. This beam failed at 38.4 kips by GFRP debonding. …
-
Evaluation of tensile and compressive membrane action in isolated slab column specimen
… slab achieved a punching shear strength of 70 kips before the first failure with 5 kips of lateral compressive force acting on the sides of the slab. It was found that the in-plane compressive forces only enhanced the capacity by 1%, but it is believed that the horizontal stiffness of the test …
-
Controlling cracking in prestressed concrete panels
… a reduction in initial prestress force from 16.1 kips per strand to 14.4 kips per strand. Another way to reduce collinear cracking would be to provide additional transverse reinforcement in the end regions of the panels. By comparing crack spacings and crack widths in current and modified panel …
-
Impact of Mass Mixing on the Lateral Resistance of Driven-Pile Foundations
… lateral resistance of the native soil was 282 kips at a pile cap displacement of 1.5 inches, and the total lateral resistance of the pile foundation treated with mass mixing was increased by 62% or 170 kips. Of the 170 kips, 90% to 100% can be attributed to the increased passive force on the …
-
Application of limit design to high-strength aluminum alloy beams
… Beyond the limit of elastic deformation (17 kips load) and up to a load of about 27 kips, the beam moments were similar to those predicted by the inelastic bending theory. From 27 kips load to failure at 32 kips, the moments were distributed in the beam differently than the predicted moments …
-
An experimental investigation of the static coefficient of friction for sheetpile interlocks
… interlock stress. At interlock loads of five kips per inch the mean coefficient of friction was approximately equal to 0.3. The relationship between interlock stress and the coefficient of friction was found to be nonlinear. An exponential model to predict the coefficient of friction for …
-
The Effect of Flowable Fill on the Lateral Resistance of Driven-Pile Foundations
… lateral resistance of the native soil was 282 kips at 1.5 inches of displacement, and the total lateral resistance of the pile foundation with flowable fill placed behind the pile cap was increased by about 53% or 150 kips. Of the 150 kips, 90% to 100% can be attributed to the increased passive …
-
A study of anchorage capacities of confined bent-bar reinforcement
… c) concrete cover Axial forces ranged from 27 kips to 55 kips. The experimental program consisted primarily of measuring the slip between the bent deformed reinforcing bar and concrete at three points and the strains on the reinforcing bars at three points also, at all the load stages until the …
-
Controlling cracking in precast prestressed concrete panels
… the current TxDOT-required prestress of 16.1 kips per strand, and the other half were fabricated with a lower prestress of 14.4 kips per strand based on initially observed prestress losses of 25 ksi or less. Thirteen of those panels were instrumented with strain gages and monitored over their …
-
Embedded Plate Connection Between Hollow-Core Slabs and Concrete Walls
… had a capacity that ranged from 8.6 to 33.5 kips when load was applied in various directions. The subassembly results indicated that the wall typically failed first, when subjected to applied loads that ranged from 2.5 to 19.8 kips. These results indicated that the proposed embedded steel …
-
Evaluation of the effects of in-plane lateral restraint and reinforcement ratio on the punching capacity of flat slab column specimens
… ratio had a punching capacity just over 69 kips which is very close to the ACI equations capacity estimation (70 kip) while the unrestrained slab with the 0.5% reinforcement ratio had a punching capacity of just under 52 kips. The effects of the addition of in-plane lateral restraint were …
-
Redefining ice loading on Minnesota’s bridges
… “Bertha” recorded static thermal thrusts of 5-6 kips and peak breakup impacts of approximately 5.5 kips, an order of magnitude below current design loads. “Bessie” data proved inconclusive due to gauge malfunctions. Photographic event logs detailed ice formation, transport, and breakup, …
Page 1 of 4