Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 32 for “"knee implant"”
-
Contact stress analysis of surface guided knee implant using finite element modeling
After Total Knee Arthroplasty, contact stresses at the surface and stresses at the implant-cement-bone interface are directly related to the joint contact forces. These stresses are a major factor in wear and fatigue, aseptic loosening, stress shielding and osteoporosis. Implant contact stresses …
-
Fit for Stability: Assessing the Role of Interference Fit in Cementless Knee Implant Stability
Total Knee Arthroplasty (TKA) is a widely performed procedure to restore knee function in patients with osteoarthritis and rheumatoid arthritis. While cemented fixation has long been the gold standard, cementless implants relying on osseointegration are increasingly used, especially for younger and …
-
The PEEK performance. Analysis of the primary fixation of a novel cementless knee implant
Radboud University, 14 november 2024
-
Porous graded biomaterial for a tibial-knee implant with minimum bone resorption and bone-implant interface micromotion
Numerous patients undergoing total knee arthroplasty (TKA) suffer from post-operative complications associated with TKA, namely end of stem pain and aseptic loosening. The mechanical mismatch between the implant and the surrounding bone has been identified as one major cause for implant failure. …
-
DESIGN AND EVALUATION OF A SELF-POWERED LOAD-SENSING KNEE IMPLANT USING COMMERCIALLY PREFABRICATED TRIBOELECTRIC GENERATOR MATERIALS
Total knee arthroplasty (TKA) failure is frequently associated with non-physiological tibiofemoral load transfer, yet existing instrumented implants rely on external power or batteries, limiting long-term clinical viability. This thesis presents the design and evaluation of a novel compliant tibial …
-
Engineering Considerations for Treatment of Prosthetic Joint Infections Using Alternating Magnetic Fields (AMF)
Treatment of infected orthopedic implants presents a major medical challenge, involving prolonged antibiotic therapy and revision surgery. This contributes to >1 billion USD in annual healthcare costs in the US alone. Exposure of metallic implants to alternating magnetic fields (AMF) generates heat …
-
On the fly: Host determinants of RNA virus evolution
Knee osteoarthritis is a common condition that can cause pain and limitations in daily life. This thesis investigated how new medical devices and advanced diagnostics can contribute to improved treatments. The results show that not every innovation automatically leads to better care: …
-
Evaluating device-related innovations and advanced diagnostics in knee osteoarthritis: from joint preservation to revision surgery
Knee osteoarthritis is a common condition that can cause pain and limitations in daily life. This thesis investigated how new medical devices and advanced diagnostics can contribute to improved treatments. The results show that not every innovation automatically leads to better care: …
-
Mechanical Design Optimisation of a Tibial Insert for use in Instrumented Total Knee Replacement
… on how to design, manufacture, and test a smart knee implant. The aim of this PhD research was to investigate how to modify a conventional tibial insert design to incorporate sensors and electronic components whilst ensuring patient safety. Several manufacturing methods were developed to address …
-
Optimising Clinical Outcome and Survival in Revision Knee Arthroplasty
… the best result. Moreover, the outcome of knee revision surgeries depends on many factors. This dissertation shows that patients with a malaligned knee implant demonstrate a clinical relevant functional improvement up to 5 years after realignment by revision surgery. Anther important aspect …
-
The Application of Zeeko Polishing Technology to Freeform Femoral Knee Replacement Component Manufacture
… into a process for the manufacture of femoral knee components to improve wear characteristics and prolong component lifetimes. It was indentified that the successful manufacture of optical components using a corrective polishing procedure to enhance their performance could be applied to femoral …
-
Numerical Simulation of Wear of Total Knee Replacements
… of a computer program to simulate the wear on knee implants over a standardized gait cycle. The contact problems during the gait cycle are formulated using linear elasticity with a linear non-penetration condition. Archard's wear law is used to estimate long-term wear. The algebraic problem …
-
Experimental and analytical study of a knee prothesis
… a human body is a challenging task for the implant designer and manufacturer. For a successful implant inside the leg, the material should be compatible, wear and chemical resistant. Uneven loading conditions and irregular shape of bone making the interface uneven, make it even more …
-
Movement strategy identification in activities of daily living : a clinical investigation of knee bearings
… one of the leading causes of disability, and the knee joint is the most commonly affected site in the body. The last resort for treatment of end-stage knee osteoarthritis is total knee arthroplasty surgery. Despite the plethora of implant designs, the current evidence on which bearings give the …
-
Movement strategy identification in activities of daily living: a clinical investigation of knee bearings
… one of the leading causes of disability, and the knee joint is the most commonly affected site in the body. The last resort for treatment of end-stage knee osteoarthritis is total knee arthroplasty surgery. Despite the plethora of implant designs, the current evidence on which bearings give the …
-
Wear of ultra-high molecular weight polyethylene manufactured with laser powder bed fusion
More than 750,000 total knee replacement (TKR) surgeries are performed annually in the United States (US) to treat degenerative joint diseases such as osteoarthritis. A prosthetic knee implant typically comprises a cobalt chromium (CoCr) femoral component and a polyethylene tibial insert that is …
-
Wear prediction in an Externally Articulating Knee Prosthesis (EAKP)
A novel conceptual knee implant has been introduced recently, which can be described as an Externally Articulating Knee Prosthesis (EAKP). The EAKP has been designed to relieve the symptoms of osteoarthritis (OA) by reducing the load experienced in symptomatic OA knee joints, without sacrificing …
-
Customized surface-guided total knee replacement for natural kinematics and deep flexion
Total knee replacements (TKRs) are developed to improve the quality of the life of patients by relieving pain and restoring normal knee function. The motivation of this dissertation was to develop and evaluate a TKR that provides close to normal kinematics for all flexion ranges, including deep …
Page 1 of 2