Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 11 of 11 for “"knee joint simulator"”.
-
Automated Quasi-static In Vitro Knee Joint Simulator: Construction and Validation
… This injury has been linked to changes in joint stability, neuromuscular activity and contact mechanics. In vitro simulators have proven to provide valuable insights on the potential effects of muscle activity on joint stability. The University of Ottawa Knee Simulate (UOKS) is a mechanical …
-
Einfluss der Lagerungsdauer und Lagerungsmethodik von Testserum aus dem Kniegelenksimulator auf die Partikelanalyse
Introduction: While complication rate of knee prosthesis is strongly associated with their particle wear, no attention has been paid on the storage method and time up to now. Material and Methods: We therefore collected bovine serum after 500.000 cycles in the knee joint simulator and evaluated …
-
Tribological evaluation of materials for replacement knee joint by a new simulator
… load, motion and contact geometry. Since a knee joint has unique functions, structure, and tribological conditions, the simulation of knee joint in the pin-on-flat configuration as commonly used is not realistic. In view of this shortcoming, an oscillating link knee joint simulator is …
-
Advancing TKA Biomechanics: From Joint Simulator to Boundary Condition Development
… experimental and computational analysis of total knee arthroplasty (TKA) components. The first study focused on the development of a novel whole knee joint simulator capable of simultaneous tibiofemoral and patellofemoral knee loading. This simulator employs custom fixturing to facilitate dynamic, …
-
Bio tribology of the patella femoral joint in total knee replacement
Total knee replacement remains the final treatment for patients suffering from knee arthritis and providing relief from pain and improvement in function. Despite the fact that the common reason for revisions of TKR is due to problems regarding patella femoral joint, the use of patella during TKA …
-
Effect of Patellar Component Thickness on Patellar Kinematics and Patellofemoral Joint Function Following Total Knee Replacement
Nowadays, instances of anterior knee pain and patellar fracture are more and more widely considered as significant complications following total knee replacement (TKR). The inability to freely flex/extend the knee after surgery has a critical influence on patients’ daily activities, which is one of …
-
Dynamic Measurements of Lubrication Film Thickness of UHMWPE Contacts for Total Joint Replacements
… First, the laboratory's force-controlled knee joint simulator was used while dynamic contact pressure measurements under both dry and lubricated conditions were made using the sensor technology employed in two different artificial knee implant geometries. Each implant was machined by the …
-
Návrh riešenia rotačného modulu pre kolenný simulátor
Bakalářská práce je zaměřena na návrh a konstrukční řešení rotačního modulu simulátoru kolenního kloubu. Účelem rotačního modulu je přiblížit simulací ke skutečným pohybům při cyklu chůze. Modul bude využíván k řízené tibiální rotace vložky. Po stanovení okrajových podmínek byly vytvořeny koncepční …
-
Konstrukce simulátoru kolenního kloubu
Diplomová práce je zaměřena na návrh a realizaci experimentálního přístroje, jehož účelem je vyvození dynamických a kinematických podmínek kolenní náhrady při cyklu chůze. Simulátor bude využíván ke studiu tvorby mazacího filmu v kontaktu stehenního dílu kolenní náhrady a polyethylenové vložky a k …
-
Vývoj součinitele tření a mazacího filmu v implantátu kolenní náhrady v průběhu cyklu chůze
Tato diplomová práce se zabývá experimentální analýzou součinitele tření a mazacího filmu u totální kolenní náhrady. Experimenty jsou provedeny na kolenním simulátoru, u kterého je v rámci řešení práce zkonstruován a implementován modul pro měření součinitele tření. Pro výzkum mazacího filmu je …
-
Návrh simulátoru pro analýzu tření v kolenním kloubu
Tato bakalářská práce se zabývá konstrukcí zařízení simulujícího kinematiku kolenního kloubu. Okrajové podmínky se inspirují normou ISO 14243-3 a na jejich základě následuje výběr vhodných komponentů. Simulátor bude schopen zaznamenávat průběh koeficientu tření mezi chrupavkou tvořící translační …