Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 47 for “"knee model"”

  1. Multidimensional coupling in a human knee model

    The thesis presents a new model for the numerical simulation of the mechanics of the human knee. In this model bones are described using linear elasticity. Ligaments instead are modelled as one-dimensional Cosserat rods. The simulations give insight into the mechanical behavior of human joints. …

    fu-berlin Repository record for Multidimensional coupling in a human knee model (opens in a new tab)

  2. Sensitivity Analysis of a Multi-Body Intact Knee Model

    Multi-body intact knee models are commonly used to investigate the biomechanical function of the knee joint. These models are simplified representations of the knee joint, with mathematical representations of the soft tissues found within the knee. Within these intact knee models, specific model …

    ohiolink Repository record for Sensitivity Analysis of a Multi-Body Intact Knee Model (opens in a new tab)

  3. A patient-specific numerical musculoskeletal knee model : application to patellar resurfacing in Total Knee Arthroplasty

    Total Knee Arthroplasty (TKA) is a well-accepted surgical treatment of severe cases of osteoarthritis. Surgery is associated with improved pain level, knee function and health-related quality of life. Despite advances in surgical techniques and implant designs during the last decades, patients …

    epfl Repository record for A patient-specific numerical musculoskeletal knee model : application to patellar resurfacing in Total Knee Arthroplasty (opens in a new tab)

  4. Development and Application of a Congruence-Based Knee Model in Anterior Cruciate Ligament Injured Adolescents

    Objective: Patient-specific musculoskeletal models have emerged as a reliable method to study how tibiofemoral joint (TFJ) morphology influences anterior cruciate ligament (ACL) injuries. However, there are no such models for adolescent populations that can be scaled to accommodate growth. To serve …

    ottawa-retro Repository record for Development and Application of a Congruence-Based Knee Model in Anterior Cruciate Ligament Injured Adolescents (opens in a new tab)

  5. A Novel Imaging System for Automatic Real-Time 3D Patient-Specific Knee Model Reconstruction Using Ultrasound RF Data

    … for automatic real-time 3D patient-specific knee model reconstruction using ultrasound RF data. The developed method uses ultrasound to transcutaneously digitize a point cloud representing the bone’s surface. This point cloud is then used to reconstruct 3D bone model using deformable models …

    utk-theses Repository record for A Novel Imaging System for Automatic Real-Time 3D Patient-Specific Knee Model Reconstruction Using Ultrasound RF Data (opens in a new tab)

  6. A Patient-Specific Knee Model Driven by In Vivo Kinematics to Better Represent an ACL-Injured Pediatric Population

    … may exceed the physiological range of the knee itself. Using OpenSim, the range of motion of the knee was constrained to allow for soft tissue artifact to be reduced. Therefore, the two objectives of this thesis are 1) to create and validate a new OpenSim knee model, and 2) to use this knee …

    ottawa-retro Repository record for A Patient-Specific Knee Model Driven by In Vivo Kinematics to Better Represent an ACL-Injured Pediatric Population (opens in a new tab)

  7. Optimization of ligament parameters on a subject-specific computational human knee model in a dynamic knee simulator using design of experiments

    … three dimensional subject-specific computational knee model. The parameters of interest are the zero load length (lambda sub zero), stiffness (k) and the strain level where the force length relationship of the ligament goes from the nonlinear "toe" region to the linear region (epsilon sub l). …

    umkc Repository record for Optimization of ligament parameters on a subject-specific computational human knee model in a dynamic knee simulator using design of experiments (opens in a new tab)

  8. Logistic regression for the modeling of low-dose radiation effects.

    … terms, this thesis will determine if a "knee" fit to a logistic regression models the data better than a simple logistic regression curve. The knee is a non-linear kink in the dose response relationship at a specific dose. If there is evidence to support the knee model hypothesis, it can …

    ottawa-retro Repository record for Logistic regression for the modeling of low-dose radiation effects. (opens in a new tab)

  9. Intraoperatively measuring ligamentous constraint and determining optimal component placement during computer-assisted total knee replacement

    The biomechanical goals of total knee replacement surgery are to restore neutral alignment to the lower limb and balance the soft tissues of the knee. Currently, this soft tissue balancing is considered an art; there are few ways to quantify the appropriateness of the soft tissue balancing that a …

    ubc Repository record for Intraoperatively measuring ligamentous constraint and determining optimal component placement during computer-assisted total knee replacement (opens in a new tab)

  10. Contact Modelling for Forward Dynamics of Human Motion

    Multibody forward dynamics models of the human body are often used in predictive simulations of human motion. An important component of these models is contact modelling. For example, foot-ground contact plays a crucial role in obtaining accurate results from a walking or running simulation and …

    waterloo Repository record for Contact Modelling for Forward Dynamics of Human Motion (opens in a new tab)

  11. Combined Cell and Gene Therapy Towards the Prevention of Osteoarthritis

    … stromal cells (MSCs) to the osteoarthritic knee joint have surfaced as a promising solution to address this clinical challenge. In this study, we addressed this by using isogenic mouse derived MSCs, combined with a novel and engineered biologic IL-1β sticky trap to prevent OA in the …

    toronto-retro Repository record for Combined Cell and Gene Therapy Towards the Prevention of Osteoarthritis (opens in a new tab)

  12. A musculoskeletal model of a subject specific knee joint with menisci, during the stance phase of a walk cycle

    Movement simulation and musculoskeletal modeling can predict muscle forces, but current methods are hindered by simplified representations of joint structures. Simulations that incorporate muscle forces, an anatomical representation of the natural knee, and contact mechanics would be a powerful …

    umkc Repository record for A musculoskeletal model of a subject specific knee joint with menisci, during the stance phase of a walk cycle (opens in a new tab)

  13. A multibody approach to the contact dynamics: a knee joint application

    … given to the articular contact at the human knee joint. Two methodologies, in two- and three-dimensions, for knee contact modeling are proposed under the framework of multibody systems using generalized Cartesian coordinates. The development of the planar multibody knee model encompasses four …

    minho-thes Repository record for A multibody approach to the contact dynamics: a knee joint application (opens in a new tab)

  14. Wear prediction in an Externally Articulating Knee Prosthesis (EAKP)

    A novel conceptual knee implant has been introduced recently, which can be described as an Externally Articulating Knee Prosthesis (EAKP). The EAKP has been designed to relieve the symptoms of osteoarthritis (OA) by reducing the load experienced in symptomatic OA knee joints, without sacrificing …

    auckland-ms Repository record for Wear prediction in an Externally Articulating Knee Prosthesis (EAKP) (opens in a new tab)

  15. A FRAMEWORK TO ESTIMATE PRESTRAIN IN SPRING AND CONTINUUM REPRESENTATIONS OF KNEE LIGAMENTS

    Computational joint models are versatile tools that offer the ability to evaluate joint mechanics under a variety of loading conditions and states that would be infeasible to evaluate experimentally. The fidelity of a computational knee model's predicted mechanics has been shown to be sensitive to …

    ohiolink Repository record for A FRAMEWORK TO ESTIMATE PRESTRAIN IN SPRING AND CONTINUUM REPRESENTATIONS OF KNEE LIGAMENTS (opens in a new tab)

  16. Biomechanical Analysis of Ligament Modelling Techniques and Femoral Component Malrotation Following TKA

    … satisfaction and revision rates following total knee arthroplasty (TKA) are lower than those of comparable surgeries such as total hip replacements. A leading cause for these revisions is joint instability which may be due to improper ligament balancing or poorly aligned surgical implants. One of …

    uwo Repository record for Biomechanical Analysis of Ligament Modelling Techniques and Femoral Component Malrotation Following TKA (opens in a new tab)

  17. Advanced Wound Care: Working towards standardised test platforms for novel therapies

    … of human skin incorporated onto a human knee model with full range of motion. Knee model control systems allow for detailed in-situ analysis of lower limb dressing performance under physiologically relevant environments and conditions such as natural gait.To find a biomechanically similar …

    hull Repository record for Advanced Wound Care: Working towards standardised test platforms for novel therapies (opens in a new tab)

Page 1 of 3