Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 40 for “"knee prosthesis"”.

  1. Below-knee prosthesis design considerations.

    … is followed by a detailed history of the below-knee prostheses worn by the author. Next, the development of a method of obtaining a precision, weight bearing impression of an amputation stump using a low exotherm, two-component froth foam, with a method of evaluating a prosthesis socket made …

    nps Repository record for Below-knee prosthesis design considerations. (opens in a new tab)

  2. Wear prediction in an Externally Articulating Knee Prosthesis (EAKP)

    A novel conceptual knee implant has been introduced recently, which can be described as an Externally Articulating Knee Prosthesis (EAKP). The EAKP has been designed to relieve the symptoms of osteoarthritis (OA) by reducing the load experienced in symptomatic OA knee joints, without sacrificing …

    auckland-ms Repository record for Wear prediction in an Externally Articulating Knee Prosthesis (EAKP) (opens in a new tab)

  3. Development of a knee prosthesis powered by electro-hydrostatic actuation

    L'abstract è presente nell'allegato / the abstract is in the attachment

    poli-torino Repository record for Development of a knee prosthesis powered by electro-hydrostatic actuation (opens in a new tab)

  4. Design of a powered above knee prosthesis using pneumatic artificial muscles

    … for both a one and two degree of freedom above-knee (AK) prosthesis actuated by pneumatic artificial muscles. Powered prosthetics aim to improve the quality of life of the 50% of AK amputees who never regain the ability to walk. Pneumatic artificial muscle (PAM) provides great potential in …

    alabama Repository record for Design of a powered above knee prosthesis using pneumatic artificial muscles (opens in a new tab)

  5. Comparative Outcomes Assessment of the C-Leg and X2 Knee Prosthesis

    … amputation (TFA). Persons with TFA use a knee prosthesis for gait and mobility. Presently, the C-Leg microprocessor knee prosthesis is the standard of care. C-Leg has significantly improved safety and cost efficacy and has created modest gains in gait efficiency. Recently, a new prosthesis …

    usf Repository record for Comparative Outcomes Assessment of the C-Leg and X2 Knee Prosthesis (opens in a new tab)

  6. A review of energy storing prosthetic feet and computer aided structural optimization of a below-knee prosthesis

    … feet. Research studies, comparing gait in below-knee amputees using different prosthetic designs, can be applied to the design of prosthetic feet that are lighter, stronger and more reliable. Comparisions among these feet are reviewed in the context of functional capability and patient …

    njit Repository record for A review of energy storing prosthetic feet and computer aided structural optimization of a below-knee prosthesis (opens in a new tab)

  7. On the Epidemiology of Soft Tissue Sarcoma and Risk of Cancer following Knee prosthesis surgery. Important factors and methodological notes

    Den aktuella avhandlingen härrör ur forskningsinsatser inom klinikerna för onkologi och ortopedi vid Universitetssjukhuset i Lund, och behandlar vad som ursprungligen verkade vara två skilda ämnen.Ena ämnet behandlar epidemiologin för mjukdelssarkom hos vuxna (MDS), en grupp av ofta dödliga …

    lund Repository record for On the Epidemiology of Soft Tissue Sarcoma and Risk of Cancer following Knee prosthesis surgery. Important factors and methodological notes (opens in a new tab) Download PDF for On the Epidemiology of Soft Tissue Sarcoma and Risk of Cancer following Knee prosthesis surgery. Important factors and methodological notes (opens in a new tab)

  8. Lower-limb robotic devices: controls and design

    … presents novel methods to control a DC powered knee prosthesis, a pneumatic prosthesis, and the progress of controlling a multifunctional orthosis. Moreover, this dissertation also presents a novel pneumatic knee prosthesis design. A novel high-level controller controls the DC powered knee …

    alabama Repository record for Lower-limb robotic devices: controls and design (opens in a new tab)

  9. CAD e engenharia reversa como ferramentas de auxílio na fabricação de cartuchos para próteses ortopédicas

    The manufacturing of above and below-knee prosthesis starts by taking surfac measurements of the patient s residual limb. This demands the making of a cartridg with appropriate fitting and customized to the profile of each patient. The traditiona process in public hospitals in Brazil begins with …

    brazil-ufrn Repository record for CAD e engenharia reversa como ferramentas de auxílio na fabricação de cartuchos para próteses ortopédicas (opens in a new tab)

  10. Einfluss der Lagerungsdauer und Lagerungsmethodik von Testserum aus dem Kniegelenksimulator auf die Partikelanalyse

    Introduction: While complication rate of knee prosthesis is strongly associated with their particle wear, no attention has been paid on the storage method and time up to now. Material and Methods: We therefore collected bovine serum after 500.000 cycles in the knee joint simulator and evaluated …

    lmu-germany Repository record for Einfluss der Lagerungsdauer und Lagerungsmethodik von Testserum aus dem Kniegelenksimulator auf die Partikelanalyse (opens in a new tab)

  11. Improving the Design Metrics of Walking Assistive Devices

    … assistive devices: an exoskeleton and above the knee prosthesis for unilateral transfemoral amputees.

    tamu Repository record for Improving the Design Metrics of Walking Assistive Devices (opens in a new tab)

  12. Microscopic wear of polymers : microscratching simulations of asperity-surface interactions and debris generation

    … is also applied to provide depth markers to a knee prosthesis tribosystem and characterise this macroscopic wear problem. These depth markers permit quantitatively in-vitro measurements of the wear rate using a knee-motion simulator. Scanning electron microscopy and atomic force microscopy are …

    unsw Repository record for Microscopic wear of polymers : microscratching simulations of asperity-surface interactions and debris generation (opens in a new tab)

  13. The development of an adaptive and reactive interface system for lower limb prosthetic application

    … and actively reduce the risk of DTI from below-knee use. The primary aim of this project was to identify whether a bespoke prosthetic socket system could actively stiffen the tissues of the lower limb. Stabilising the residual tibia during ambulation and reducing stress concentrations on the …

    strathclyde Repository record for The development of an adaptive and reactive interface system for lower limb prosthetic application (opens in a new tab)

  14. Η ολική αρθροπλαστική του γόνατος με ενδοπρόθεση τύπου gliding meniscal knee: Κλινική αξιολόγηση 230 περιπτώσεων

    In this thesis 230 total knee replacements with the Gliding Meniscal Knee prosthesis are reviewed; they were all performed by the same surgeon. The patients' age was from 33 to 88 (mean 66.28), of which 23.48% were men and 76.52% women, 56.96% osteoarthritic and 43.03% rheumatoid. The continuous …

    greece Repository record for Η ολική αρθροπλαστική του γόνατος με ενδοπρόθεση τύπου gliding meniscal knee: Κλινική αξιολόγηση 230 περιπτώσεων (opens in a new tab)

Page 1 of 2