Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 80 for “"knee replacements"”.

  1. CoCrMo alloys in hip and knee replacements application

    CoCrMo alloys have been widely used in hip replacements. On the one hand, they have exhibited excellent long-term survival rates, but recently high failure rates have been observed, associated with adverse local tissue reactions. It is still a puzzle why CoCrMo alloys sometimes work very well, …

    whiterose Download PDF for CoCrMo alloys in hip and knee replacements application (opens in a new tab)

  2. Numerical Simulation of Wear of Total Knee Replacements

    … of a computer program to simulate the wear on knee implants over a standardized gait cycle. The contact problems during the gait cycle are formulated using linear elasticity with a linear non-penetration condition. Archard's wear law is used to estimate long-term wear. The algebraic problem …

    qucosa-diss

  3. Wear and Boundary Lubrication in Modular Total Knee Replacements

    … resorption) can lead to failure of modular total knee replacements and make expensive revision surgery necessary. Gamma-in-air sterilization of the PE insert and having a modular tibial component are both risk factors for excessive backside wear that contribute to osteolysis and implant failure. …

    waterloo Repository record for Wear and Boundary Lubrication in Modular Total Knee Replacements (opens in a new tab)

  4. Piezoresistive UHMWPE WMCNT Sensors for Instrumented Total Knee Replacements

    … developed and validate an instrumented total knee replacement using a novel piezoresistive polymeric sensor. The addition of multi-walled carbon nanotubes (MWCNT) as electrically conducting fillers to the ultra-high molecular weight polyethylene (UHMWPE) transforms the electrically insulating …

    unsw Repository record for Piezoresistive UHMWPE WMCNT Sensors for Instrumented Total Knee Replacements (opens in a new tab)

  5. Total Knee Replacements: Component Design, Pain Prevention and Research Techniques

    Total knee arthroplasty is a surgical procedure in which the knee is resurfaced with implants to relieve pain. This thesis presents computed tomography and radiography methods to determine the relative position (kinematics) for the patellofemoral and tibiofemoral joints in vivo for a full range of …

    calgary Repository record for Total Knee Replacements: Component Design, Pain Prevention and Research Techniques (opens in a new tab)

  6. PRIMARY FLEXION AXIS SELECTION IN TOTAL KNEE REPLACEMENTS USING COMPUTATIONAL ANALYSIS

    Total knee replacements (TKR) are one of the most frequently implanted medical devices, with over 600,000 procedures performed in the United States in 2012. In order to ensure TKR longevity, wear tests are frequently conducted on these implants prior to patient implantation. Variations in implant …

    clemson Repository record for PRIMARY FLEXION AXIS SELECTION IN TOTAL KNEE REPLACEMENTS USING COMPUTATIONAL ANALYSIS (opens in a new tab)

  7. Multiobjective Design Optimization of Total Knee Replacements Considering UHMWPE Wear and Kinematics

    Total knee replacement is the gold standard treatment for restoring mobility and relieving pain associated with osteoarthritis when other medical therapy has failed. Revision surgery is necessary when the replaced knee fails, which is often a result of implant damage (such as wear) or poor …

    queens Repository record for Multiobjective Design Optimization of Total Knee Replacements Considering UHMWPE Wear and Kinematics (opens in a new tab)

  8. Polyethylene wear modeling in modular total knee replacements using finite element simulation

    … and backside polyethylene (PE) wear of total knee replacements (TKRs) could enable the optimization of TKRs for the reduction of polyethylene wear, thereby improving the long term success of TKRs. A finite element model was developed for the TKR and the results were implemented in a …

    manitoba Repository record for Polyethylene wear modeling in modular total knee replacements using finite element simulation (opens in a new tab)

  9. A Finite Element Analysis of Tibial Stem Geometry for Total Knee Replacements

    … shielding of the tibia for patients with a total knee replacement. Finite element analysis was used to study different tibial stem geometry types, as well as a vast array of different geometric sizes. Both a peg and stem type geometry were analyzed and compared in order to determine what type …

    calpoly Repository record for A Finite Element Analysis of Tibial Stem Geometry for Total Knee Replacements (opens in a new tab)

  10. Enhancing Value-Based Healthcare with Reconstructability Analysis: Predicting Risk for Hip and Knee Replacements

    … Analysis (RA) to data on hip and knee replacement surgery, and considered whether RA could create useful models of outcomes, and whether these models could produce predictions complimentary to or even stronger than LR models. RA is a data mining method that searches for relations …

    portland-state Repository record for Enhancing Value-Based Healthcare with Reconstructability Analysis: Predicting Risk for Hip and Knee Replacements (opens in a new tab)

  11. Computational wear simulations in total knee replacements with consideration for energy dissipation and colloid-mediated boundary lubrication

    … simulations may enable the optimization of total knee replacements for the reduction of polyethylene wear, thereby potentially improving the long term success of total knee replacements. However, previously existing computational wear models have only demonstrated weak correlations (R2<0.65) in …

    manitoba Repository record for Computational wear simulations in total knee replacements with consideration for energy dissipation and colloid-mediated boundary lubrication (opens in a new tab)

  12. An Evaluation of the Primary-to-Specialist Referral System for Elective Hip and Knee Replacements in Alberta

    … To measure how changes in elective hip and knee arthroplasty referral processing for primary-to-specialist surgical consultations may impact accessibility, referral appropriateness, and efficiency. Methods: I documented current referral practices by conducting semi-structured interviews with …

    calgary Repository record for An Evaluation of the Primary-to-Specialist Referral System for Elective Hip and Knee Replacements in Alberta (opens in a new tab)

  13. An Experimental Study of an Advanced Polymeric Material for Use in Total Knee Replacements Including Gait Analysis of Mobile Knee Bearings

    … Stress (LCS)™ Rotating Platform and Meniscal knee bearing systems and to investigate the tribological properties of a new polymer for potential application in total joint replacement. Thus, clinical studies were performed on subjects having the LCSTM Rotating Platform knee bearing and subjects …

    odu Repository record for An Experimental Study of an Advanced Polymeric Material for Use in Total Knee Replacements Including Gait Analysis of Mobile Knee Bearings (opens in a new tab)

  14. Research into the Design and Validation of an Innovative Intraoperative Load Sensor for Total Knee Replacements through Experimental and Cadaveric Investigations

    Balancing the force between compartments in the knee joint during a Total Knee Replacement (TKR) is a vital parameter for surgeons to achieve successful outcomes for patients due to the complexity of the joint, articulating surfaces, tendons, and ligaments. These structures are all impacted by the …

    bournemouth Download PDF for Research into the Design and Validation of an Innovative Intraoperative Load Sensor for Total Knee Replacements through Experimental and Cadaveric Investigations (opens in a new tab)

  15. The association between surgeon grade and implant survival following hip and knee replacement

    Over 2.5 million primary hip and knee replacements have been performed in England and Wales since the inception of the National Joint Registry (NJR) in 2003. These common procedures provide a cost effective means of treating end-stage osteoarthritis. However, implant constructs are susceptible to …

    bristol Repository record for The association between surgeon grade and implant survival following hip and knee replacement (opens in a new tab) Download PDF for The association between surgeon grade and implant survival following hip and knee replacement (opens in a new tab)

  16. Spatial Sensors for Quantitative Assessment of Retrieved Arthroplasty Bearings

    … of arthroplasty bearings, including total knee replacements, unicompartmental knee replacements, and total hip replacements. The approach is to assess bearings that endured a finite duration of function in patients, with particular emphasis on expanding our understanding of the …

    clemson Repository record for Spatial Sensors for Quantitative Assessment of Retrieved Arthroplasty Bearings (opens in a new tab)

  17. Methods for medical device and surgical epidemiology: applications in knee replacement and COVID-19 related tracheotomy

    … the effectiveness and safety of partial vs total knee replacement and evaluated them by comparing observational results to those from a randomised controlled trial. I applied the target trial framework to the study of the timing of tracheostomy in patients with COVID-19. I further studied the …

    oxford Repository record for Methods for medical device and surgical epidemiology: applications in knee replacement and COVID-19 related tracheotomy (opens in a new tab)

  18. ELDERLY SINGAPOREANS' PERCEPTIONS OF UNDERGOING JOINT REPLACEMENT SURGERY: A QUALITATIVE STUDY

    TOTAL HIP AND KNEE REPLACEMENTS ALLEVIATE PAIN AND DISABILITY, RESTORE FUNCTION AND IMPROVE A PATIENT?S QUALITY OF LIFE. THE AIM OF THIS STUDY WAS TO EXPLORE THE PERCEPTION OF ELDERLY SINGAPOREANS UNDERGOING JOINT REPLACEMENT SURGERY. A DESCRIPTIVE QUALITATIVE DESIGN WAS UTILISED AND GUIDED BY THE …

    nus Repository record for ELDERLY SINGAPOREANS' PERCEPTIONS OF UNDERGOING JOINT REPLACEMENT SURGERY: A QUALITATIVE STUDY (opens in a new tab) Download file for ELDERLY SINGAPOREANS' PERCEPTIONS OF UNDERGOING JOINT REPLACEMENT SURGERY: A QUALITATIVE STUDY (opens in a new tab)

  19. Monitoring Quality of Care for Joint Replacements: Assessing Alternative Statistical Methods to Accurately Estimate Time to Revision

    … physically active patients are receiving joint replacements, it has become increasingly important to measure the failure rate for joint replacements using the cumulative incidence of revision. The most commonly applied survival analysis technique, the Kaplan-Meier (KM) method, does not account …

    calgary Repository record for Monitoring Quality of Care for Joint Replacements: Assessing Alternative Statistical Methods to Accurately Estimate Time to Revision (opens in a new tab)

Page 1 of 4