Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"knee simulator"”.

  1. Wear of polyethylene and hylamer on cobalt-chromium : a knee simulator study

    … characteristics of tibial bearings used in total knee replacement systems. Each test consisted of six A/P Glide Tibial Bearings each having a conical control arm. The plastic portion of the conical bearings were all made of UHMWPe. Each of these bearing systems was mounted onto a Co-Cr alloy …

    njit Repository record for Wear of polyethylene and hylamer on cobalt-chromium : a knee simulator study (opens in a new tab)

  2. A Neural Network Approach to Physiological Joint Loading Profile Generation in the Kansas Knee Simulator

    … complex physiological joint loads in an in-vitro simulator allows for research that can be used to improve the outcome of prosthetic design, characterize knee laxity, and evaluate the mechanics of injury. Producing physiological in-vivo loads in an in-vitro simulator can prove challenging due to …

    ku Repository record for A Neural Network Approach to Physiological Joint Loading Profile Generation in the Kansas Knee Simulator (opens in a new tab)

  3. Tibio-femoral Joint Contact Mechanics: An In-vitro Simulation with a 6 DOF Static Knee Simulator

    … relationship between muscle loads crossing the knee joint and knee joint mechanics is critical for understanding knee stability and the effects of altered muscle forces on healthy and ACL injured knees. In vitro measurement can be used to elucidate this if the simulation is biofidelic, allowing …

    ottawa-retro Repository record for Tibio-femoral Joint Contact Mechanics: An In-vitro Simulation with a 6 DOF Static Knee Simulator (opens in a new tab)

  4. Optimization of ligament parameters on a subject-specific computational human knee model in a dynamic knee simulator using design of experiments

    … three dimensional subject-specific computational knee model. The parameters of interest are the zero load length (lambda sub zero), stiffness (k) and the strain level where the force length relationship of the ligament goes from the nonlinear "toe" region to the linear region (epsilon sub l). …

    umkc Repository record for Optimization of ligament parameters on a subject-specific computational human knee model in a dynamic knee simulator using design of experiments (opens in a new tab)

  5. Polyethylene wear modeling in modular total knee replacements using finite element simulation

    … and backside polyethylene (PE) wear of total knee replacements (TKRs) could enable the optimization of TKRs for the reduction of polyethylene wear, thereby improving the long term success of TKRs. A finite element model was developed for the TKR and the results were implemented in a …

    manitoba Repository record for Polyethylene wear modeling in modular total knee replacements using finite element simulation (opens in a new tab)

  6. Computational wear simulations in total knee replacements with consideration for energy dissipation and colloid-mediated boundary lubrication

    … simulations may enable the optimization of total knee replacements for the reduction of polyethylene wear, thereby potentially improving the long term success of total knee replacements. However, previously existing computational wear models have only demonstrated weak correlations (R2<0.65) in …

    manitoba Repository record for Computational wear simulations in total knee replacements with consideration for energy dissipation and colloid-mediated boundary lubrication (opens in a new tab)

  7. Quantifying the Effect of Sagittal Plane Loading on Anterior-Posterior and Compressive Knee Loads during Dynamic Simulations

    Dynamic in-vitro knee simulator's ability to achieve physiological compression and A-P loads is dependent on the chosen axes of applied loads in the sagittal plane. Anterior-posterior (A-P) and compressive forces generated at the tibia during dynamic activities have a large influence on the joint …

    ku Repository record for Quantifying the Effect of Sagittal Plane Loading on Anterior-Posterior and Compressive Knee Loads during Dynamic Simulations (opens in a new tab)

  8. An investigation of polyethylene bearing wear of New Jersey LCS knee on cobalt chromium and titanium nitride types

    The total knee replacement systems (TKRS) are used for the treatment of osteoarthritis and rheumatoid arthritis. Excessive wear can substantially shorten their life span. Two tests were performed to examine the wear characteristics of tibial bearings used in TKRS. Each test consisted of six sets of …

    njit Repository record for An investigation of polyethylene bearing wear of New Jersey LCS knee on cobalt chromium and titanium nitride types (opens in a new tab)

  9. A musculoskeletal model of a subject specific knee joint with menisci, during the stance phase of a walk cycle

    … an anatomical representation of the natural knee, and contact mechanics would be a powerful tool in orthopedics. This study developed a subject specific computational model of the knee with menisci within the multibody framework. The model was validated with experimental measurements from a …

    umkc Repository record for A musculoskeletal model of a subject specific knee joint with menisci, during the stance phase of a walk cycle (opens in a new tab)

  10. Bio tribology of the patella femoral joint in total knee replacement

    Total knee replacement remains the final treatment for patients suffering from knee arthritis and providing relief from pain and improvement in function. Despite the fact that the common reason for revisions of TKR is due to problems regarding patella femoral joint, the use of patella during TKA …

    whiterose Download PDF for Bio tribology of the patella femoral joint in total knee replacement (opens in a new tab)

  11. High flexion kinematics and kinetics for the improvement of artificial knee joints

    Total knee arthroplasty has been effective in reducing pain, but less so in restoring function, especially for activities requiring deep knee flexion. The philosophy of this dissertation was that more functionally effective and optimally designed artificial knees could be created for high flexion …

    queens Repository record for High flexion kinematics and kinetics for the improvement of artificial knee joints (opens in a new tab)

  12. Wear and Boundary Lubrication in Modular Total Knee Replacements

    … resorption) can lead to failure of modular total knee replacements and make expensive revision surgery necessary. Gamma-in-air sterilization of the PE insert and having a modular tibial component are both risk factors for excessive backside wear that contribute to osteolysis and implant failure. …

    waterloo Repository record for Wear and Boundary Lubrication in Modular Total Knee Replacements (opens in a new tab)

  13. Combined Experimental and Statistical Model to Understand the Role of Anatomical and Implant Alignment Variables in Guiding Knee Joint Motion

    … experimental method to manually assess passive knee envelope was described. Principal component (PC) model was developed for the varus-valgus (V-V), internal-external (I-E) and anterior-posterior (A-P) envelope using twenty-one native cadaveric knees and the mode of envelope variations were …

    ku Repository record for Combined Experimental and Statistical Model to Understand the Role of Anatomical and Implant Alignment Variables in Guiding Knee Joint Motion (opens in a new tab)

  14. Design of a Cyclic Sliding, Dynamically Loaded Wear Testing Device for the Evaluation of Total Knee Replacement Materials

    … normal walking, the relative motion of the human knee involves flexion/extension, anterior/posterior sliding, and medial/lateral rotation. As well, the knee experiences a complex, dynamic loading curve with a peak of up to seven times body weight. However, most wear testing machines that have been …

    vt Repository record for Design of a Cyclic Sliding, Dynamically Loaded Wear Testing Device for the Evaluation of Total Knee Replacement Materials (opens in a new tab)

  15. Computational Methodology for Generating Patient-Specific Soft Tissue Representations

    … a computational model of an experimental knee simulator for simultaneous evaluation of tibiofemoral and patellofemoral mechanics. The model's predictions were verified against experimental measurements, providing a reliable computational tool for further studies. The fourth study …

    denver Repository record for Computational Methodology for Generating Patient-Specific Soft Tissue Representations (opens in a new tab)

  16. Piezoresistive UHMWPE WMCNT Sensors for Instrumented Total Knee Replacements

    … developed and validate an instrumented total knee replacement using a novel piezoresistive polymeric sensor. The addition of multi-walled carbon nanotubes (MWCNT) as electrically conducting fillers to the ultra-high molecular weight polyethylene (UHMWPE) transforms the electrically insulating …

    unsw Repository record for Piezoresistive UHMWPE WMCNT Sensors for Instrumented Total Knee Replacements (opens in a new tab)

  17. CONTRA-COMPARTMENTAL JOINT MECHANICS IN UNICONDYLAR KNEE ARTHROPLASTY

    Recently, unicondylar knee arthroplasty (UKA) has seen a resurgence in clinical popularity, due to its increased success rate, improvement in implant designs, and more efficient surgical techniques. However, it continues to be a more technically demanding procedure and less forgiving compared to …

    clemson Repository record for CONTRA-COMPARTMENTAL JOINT MECHANICS IN UNICONDYLAR KNEE ARTHROPLASTY (opens in a new tab)

  18. Assessing Stability of the Knee In Vitro Using Envelope Normalized Kinematics and Principal Component Analysis

    … during three gait simulations run on the Kansas Knee Simulator using PCA. Gait kinematics and envelope kinematics for fourteen natural knees were placed into one principal component model and the mode of variations were identified. This was done for anterior-posterior, internal-external, and …

    ku Repository record for Assessing Stability of the Knee In Vitro Using Envelope Normalized Kinematics and Principal Component Analysis (opens in a new tab)

  19. Wear of a total ankle replacement

    … parameters for the Zentih (Corin Group) TAR. A knee simulator was used to vary the combination of rotation and displacement and the change in wear rate was assessed gravimetrically. The effects of malalignment were investigated biomechanically in terms of component lift-off, changing contact …

    whiterose Download PDF for Wear of a total ankle replacement (opens in a new tab)

Page 1 of 2