Finite element modelling and evaluation of welding procedures in high strength (450 Mpa : 65 Ksi) W - shape column assemblies
The use of high strength steel has become more frequent in modern steel construction due to the increasing demand for taller buildings and longer spans. High strength stocky steel columns are often used as part of a building's primary lateral load resisting system. During the fabrication of welded …
-
A Comparative Study on the Fatigue Performance of Welded 8630 Cast Steel Using Class 110 ksi Flux-Cored Wires
… steel using two same class undermatching 110 ksi flux cored wires. The two filler wires had similar chemical compositions with similar carbon equivalent although wire 2 contained V and Cr and had a higher amount of sulfur than wire 1.The average ultimate tensile strength (UTS) of the 8630 cast …
-
Caracterização da microestrutura, propriedades mecânicas e resistência à corrosão de tubo sem costura de aço inoxidável superduplex UNS S39274 deformado para um limite de escoamento de 125 KSI
O objetivo deste trabalho foi caracterizar a microestrutura, propriedades mecânicas e resistência à corrosão de um tubo sem costura deformado a frio de aço inoxidável superduplex UNS S32974. Para isso, o estudo comparativo foi feito tomando por referência duas condições: o material como recebido …
-
Design of Special Concentrically Braced Frames using High Strength Steel
… as steel with a yield strength greater than 65 ksi (450 MPa). This steel has gained popularity in building construction worldwide due to its satisfactory toughness, weldability and ductility. However, the use and application of HS3 as a structural material has been limited in the United States, …
-
Refined Evaluation of Effective Prestress in the Varina-Enon Bridge
… effective prestress ranged from 167.4 ksi to 170.8 ksi. Both new methods for live load moment calculation yielded slightly smaller values for effective prestress compared to the method used previously. Increasing the elastic modulus from 6000 ksi to 6200 ksi increased back-calculated …
-
Numerical Investigation of Local Buckling Behavior of High Strength Steel Wide Flange Columns
… as steel with a yield strength greater than 65 ksi (450 MPa), has gained popularity worldwide in the building industry due to its superior strength to weight ratio, and satisfactory ductility and toughness. However, the use of HS3 steel for design as a structural member in the United States has …
-
Long-Term Monitoring and Evaluation of the Varina-Enon Bridge
… model predicted the prestress losses as 44.6 ksi in Span 5, 47.9 ksi in Span 6, 45.3 ksi in Span 9, and 45.9 ksi in Span 11. The prestress losses estimated from field data were 50.0 ksi in Span 5, 48.0 ksi in Span 6, 46.7 ksi in Span 9, and 49.1 ksi in Span 11. It can be seen that relative to …
-
Performance of tension lap splices with MMFX high strength reinforcing bars
… a minimum ultimate tensile capacity of 150 ksi and a minimum yield strength of 100 ksi when measured using the 0.2% elongation method. To safely utilize the high strength of MMFX steel in design, proper anchorage of the reinforcement must be provided. Development length equations included in …
-
Effective Prestress Evaluation of the Varina-Enon Bridge Using a Long-Term Monitoring System and Finite Element Model
… predicted by the finite element model were 44.9 ksi in Span 5, 47.8 ksi in Span 6, and 45.3 ksi in Span 9. The prestress losses estimated from field data were 50.0 ksi in Span 5, 48.0 ksi in Span 6, and 46.7 ksi in Span 9. The field data estimates were consistently greater than the finite element …
-
Machining of silicon wafers with an abrasive water jet cutter
… was obtained under cutting conditions of 30 KSI water pressure, 1 inch/minute cutting speed, and an abrasive flow rate of 56 grams/minute. Other trends in the data show the optimum cutting speed to be between 1 and 2 inches/ minute. The water pressure of 30 KSI achieved better results than …
-
Moment Redistribution of Continuous Hybrid Highway Bridge I-Girders Fabricated from HPS-100W Steel
… with specified minimum yield strength of 100.0 ksi and 50.0 ksi., respectively. Through finite element modeling, it was found that AASHTO (2010) predictions for moment-rotation behaviors are similar for a full-length continuous steel hybrid highway bridge I-girder fabricated from HPS-100W …
-
Kitchen science investigators: promoting identity development as scientific reasoners and thinkers
… technologies. Kitchen Science Investigators (KSI) is an out-of-school transformative learning environment we designed to help young people learn science through cooking. My dissertation considers the question, 'How can we design a learning environment in which children discover the utility of …
-
Standardization of test methods for property evaluation of FRP bars
… strengths of FRP bars were found to be 256 ksi (ribbed carbon ), 83 to 77 ksi (ribbed glass), 82 to 67 ksi ( sand coated glass), and 173 ksi (sand coated aramid). (Abstract shortened by UMI.).
-
Fatigue tests of slender-web hybrid plate girders under combined moment and shear
… that produced a maximum flange stress of 50 ksi and a shear stress of about 12. 5 ksi. The girder flanges were constructional alloy steel with a minimum yield point of 100 ksi, and the webs were carbon steel with a minimum yield point of 36 ksi. The objectives of this investigation were: (1) …
-
Responses of ten soybean [ glycine max (L.) merrill] genotypes for yield and nodulation to trichoderma and silicon applications.
… max L.) genotypes to potassium silicate (KSi) and Trichoderma harzianum (Eco-T®) applications. Preliminary studies involving two independent experiments were conducted under controlled conditions at the University of KwaZulu-Natal during 2010. Potassium silicate at three concentrations (0, …
-
Isolation and screening of freshly isolated bradyrhizobium and rhizobium spp. for multi-host plant growth promotion.
… used in combination with potassium silicate (KSi), to determine their combined effects on chlorophyll content and dry biomass. A full factorial trial was not conducted due to lack of glasshouse space. The 17 rhizobial isolates, 2 commercial rhizobial strains and 4 fertilizer controls (0% …
-
Development of an Economical Ultra-High-Performance Concrete Mix Using Local Materials
… a compressive strength greater than 17.4 ksi (120 MPa) and a post-cracking tensile strength greater than 0.72 ksi (5 MPa). Due to these exceptional mechanical properties and durability properties, UHPC is being increasingly utilized in critical infrastructure projects, such as nuclear …
-
Experimental investigation of the effect of spin on traction in elastohydrodynamically lubricated contacts
… at maximum Hertzian contact pressures of 300 KSI, 333 KSI, 400 KSI, and 450 KSI. The angle between the axis of the driven ball and the normal to the plane of contact was varied from 40° to 50° and data were taken to determine the relation between coefficient of traction and percent slip for …
-
INFLUENCE OF CATHODIC PROTECTION UPON CONSTANT DEFLECTION FATIGUE TESTS ON NOTCHED 1018 STEEL IN SEA WATER
… the beginning of testing . At stresses above 22 ksi (152 MN/m^2), cracks grew continuously across the bars. At stresses below 22 ksi (152 MN/m^2), and at potentials of -1.20 volts , saturated calomel electrode SCE, cracks did not grow, or arrested part way across the bar. At potentials other than …
-
Controlling cracking in prestressed concrete panels
… assumes total prestress losses of 45 ksi. Based on eight panel specimens, instrumented and fabricated at two different precast plants in Texas, actual prestress losses were measured as at most 25 ksi. This difference (about 20 ksi) is consistent with a reduction in initial prestress …
Page 1 of 14